MedPath

A Head-to-Head Comparison of A New Perfusion Tracer, 99mTc-4BOH vs. 13N-NH3 to Evaluate Diagnostic Efficacy of Ischemic Heart Disease

Not Applicable
Not yet recruiting
Conditions
Coronary Artery Disease
Registration Number
NCT06980194
Lead Sponsor
China National Center for Cardiovascular Diseases
Brief Summary

The objective of the study is to assess the diagnostic efficacy (specificity and sensitivity) of 99mTc-4BOH SPECT myocardial perfusion imaging (MPI) compared to 13N-ammonia PET MPI in the detection of significant coronary artery disease (CAD) as defined by invasive coronary angiography (ICA).

Detailed Description

The goal of this trial is to evaluate whether SPECT myocardial perfusion using the novel tracer 99mTc-4BOH is non-inferior to 13N-ammonia PET in diagnosing myocardial ischemia in patients with fractional flow reserve (FFR) as the diagnostic gold standard. In this study, 13N-ammonia PET imaging will be used as the positive control. Patients with diagnosed CAD who are scheduled for myocardial perfusion imaging will be assigned to undergo head-to-head SPECT imaging with 99mTc-4BOH and PET imaging with 13N-ammonia, with no more than 7 days between scans. All participants will subsequently undergo coronary angiography with FFR measurement within 30 days of imaging. The diagnostic performance of 99mTc-4BOH will be compared to that of 13N-ammonia, using FFR as the reference standard.

Recruitment & Eligibility

Status
NOT_YET_RECRUITING
Sex
All
Target Recruitment
300
Inclusion Criteria
  • Age between 18 and 80 years. Presence of angina symptoms, such as chest tightness or chest pain. Coronary CT angiography (CTA) indicating ≥50% stenosis in at least one coronary artery.

Able and willing to provide written informed consent.

Exclusion Criteria
  • Underwent coronary revascularization (PCI or CABG) within the past 6 months. Presence of non-ischemic heart disease or left ventricular ejection fraction (LVEF) <35%.

Contraindications to adenosine stress (e.g., bronchial asthma, second-degree or higher atrioventricular block, severe hypotension).

Pregnancy or lactation. Unable or unwilling to sign the informed consent form.

Study & Design

Study Type
INTERVENTIONAL
Study Design
SINGLE_GROUP
Primary Outcome Measures
NameTimeMethod
Diagnostic accuracy of 99mTc-4BOH SPECT imaging for detecting myocardial ischemia, using FFR as the reference standardWithin 30 days after both imaging procedures

Diagnostic accuracy (sensitivity, specificity, positive predictive value, negative predictive value) of 99mTc-4BOH SPECT myocardial perfusion imaging in detecting myocardial ischemia, compared to fractional flow reserve (FFR ≤0.80) as the diagnostic gold standard.

Secondary Outcome Measures
NameTimeMethod
Non-inferiority of 99mTc-4BOH SPECT vs. 13N-ammonia PET in detecting myocardial ischemiaWithin 30 days after imaging and FFR

Assessment of the non-inferiority of 99mTc-4BOH SPECT imaging compared to 13N-ammonia PET imaging in detecting myocardial ischemia, using FFR as the gold standard. Analysis will be based on paired comparison and pre-specified non-inferiority

© Copyright 2025. All Rights Reserved by MedPath