MedPath

Pre-Surgical Ocular Surface Treatment With Intracanalicular Dexamethasone Insert And Effect On Intraocular Lens Measurement Accuracy

Phase 4
Conditions
Ocular Surface Disease
Cataract Surgery
Dry Eye Disease
Interventions
Registration Number
NCT04530864
Lead Sponsor
Prism Vision Group
Brief Summary

This prospective study will use a self controlled design for 35 eyes. Patients scheduled to undergo routine cataract surgery in at least one of their eyes will have their pre-surgical measurements performed, IOL calculated and surgery planned. Then they will receive insertion of an intracanalicular dexamethasone insert into the inferior punctum. At 2 weeks (+/- 2 days) post-insertion, patients will return for an identical set of measurements. The IOL will be calculated and the surgery planned based on post-insert data. The insert will be removed if present (manually or via saline irrigation). This self controlled design allows for greater control of potential confounders tied to participants' systemic and ocular health.

Detailed Description

Ocular surface optimization is a pre-operative necessity. In cataract surgery patients, an unstable tear film reduces the quality of corneal reflections and therefore can compromise K readings, which in turn can affect the accuracy of IOL calculations and result in suboptimum refractive results. To obtain accurate measurements, patients are routinely pre-treated with a variety of medications and therapies. However, these therapies can take time, which may lead to surgical delays.

Steroids can positively impact the stability of the tear film by inhibiting and preventing ocular surface inflammation. Punctal plugs are also widely used for the treatment of dry eye manifestations, by blocking the tear drainage, increasing tear film and eye moisture. Dextenza is a sustained-release dexamethasone intracanalicular insert recently approved by the FDA for pain and inflammation post ophthalmic surgery. It is placed into the canaliculus via the lower punctum and is designed to release steroid medication for 30 days.

Previous studies have demonstrated that ocular surface disease affects the reliability of IOL calculations, potentially affecting outcomes. The insert of a punctal plug that can deliver a sustained release of dexamethasone to the eye 2 weeks (+/- 2 days) prior to final preoperative measurements may provide adequate therapy, improving the ocular surface status and, therefore, improve the reliability of IOL selection in patients undergoing cataract surgery, in a comparatively short amount of time, without introducing patient compliance barriers.

Pre-surgical measurements, IOL calculations, and surgical plans prior to the insertion of the insert will be compared to measurements, IOL calculations, and surgical plans at 2 weeks following intracanalicular dexamethasone insertion. Surgery will proceed with data from the post-insert measurements. Final refractive outcomes at one month from the second eye surgery will be compared to pre-insert data to determine refractive accuracy.

Recruitment & Eligibility

Status
UNKNOWN
Sex
All
Target Recruitment
35
Inclusion Criteria
  • 18 years or older
  • Visually significant cataract
  • Dry eye disease
  • BCVA potential of 20/40 or better
Read More
Exclusion Criteria
  • Pregnancy
  • Concurrent use of topical glaucoma medications
  • Corneal scarring
  • History of LASIK or PRK
  • History of rigid gas permeable (RGP) lens wear
  • Macular or retinal pathology requiring intervention
  • Cataract surgery complications
Read More

Study & Design

Study Type
INTERVENTIONAL
Study Design
SINGLE_GROUP
Arm && Interventions
GroupInterventionDescription
DEXTENZA InsertDextenza 0.4Mg Ophthalmic InsertThis prospective study will use a self controlled design for 35 eyes. Patients scheduled to undergo routine cataract surgery in at least one of their eyes will have their pre-surgical measurements performed, IOL calculated and surgery planned. Then they will receive insertion of an intracanalicular dexamethasone insert into the inferior punctum. At 2 weeks (+/- 2 days) post-insertion, patients will return for an identical set of measurements. The IOL will be calculated and the surgery planned based on post-insert data. The insert will be removed if present (manually or via saline irrigation). This self controlled design allows for greater control of potential confounders tied to participants' systemic and ocular health.
Primary Outcome Measures
NameTimeMethod
The change in baseline data (power calculation and astigmatism management) measured by IOL Master 700 and post insert of Dextenza data (power calculation and astigmatism management) measured by IOL Master 700.at 8 weeks (Day 0) and final refractive outcome 1 month post-op visit
Secondary Outcome Measures
NameTimeMethod
Change in Tear Break-up Time6 weeks BEFORE surgery from pre-insert at 8 weeks BEFORE surgery
Change in Standard Patient Evaluation of Eye Dryness Questionnaire (SPEED)6 weeks BEFORE surgery from pre-insert at 8 weeks BEFORE surgery

The Standard Patient Evaluation of Eye Dryness Questionnaire (SPEED) evaluates both the frequency and severity of symptoms. The patient grades the severity of her symptoms on a scale of zero to four with zero being no symptoms and four being intolerable symptoms. The numeric value for each answer is simply added with scores ranging from zero to 28. 0-4 MILD dry eye symptoms, 5-7 MODERATE dry eye symptoms, + SEVERE dry eye symptoms.

The change in inflammatory markers measured by MMP96 weeks BEFORE surgery from pre-insert at 8 weeks BEFORE surgery
© Copyright 2025. All Rights Reserved by MedPath