跳至主要内容
临床试验/NCT05002790
NCT05002790已完成不适用

A Magnetic Resonance Imaging Study of Changes in the Angle Between the Tracheal and Laryngeal Axes in the Sniffing, Neutral and Extended Head and Neck Positions for Videolaryngoscopy

University Hospitals Coventry and Warwickshire NHS Trust2 个研究点 分布在 1 个国家目标入组 20 人开始时间: 2021年8月5日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
入组人数
20
试验地点
2
主要终点
Angle A Measured on MRI

研究概览

简要总结

The traditional method of tracheal intubation requires the insertion of a laryngoscope into the oral cavity and directly visualisation of the glottis. The traditional head position called the sniffing the morning air position; consisting of lower cervical flexion and extension of the atlanto-occipital joint is commonly used to facilitate tracheal intubation in this manner by aligning the oral axes and providing the operator a view of the glottis.

With the advancement of technology, has seen videolaryngoscopes (VL) developed to ease tracheal intubation. With VL, the glottis is seen through a camera connected to a viewing screen either attached to the top of the laryngoscope or connected to a camera screen by cable. One of the main drawbacks with VL is that a good view of the glottis is seen on the screen, but it can be difficult to pass the tracheal tube through the glottis in comparison to the traditional intubation technique described above. One of the main factors the authors suggest is that VL-assisted intubation requires a head and neck position that is different to the sniffing the morning air position.

This study aims to assess the oral axes in three different head and neck positions under MRI to assess which positions improve axial alignment the most.

详细描述

The traditional method of tracheal intubation requires the insertion of a laryngoscope with the left hand into the oral cavity to displace the tongue and directly visualise the glottis.

The sniffing the morning air (or sniffing) position has been traditionally used for tracheal intubation using direct laryngoscopy. This comprises of flexion of the lower cervical spine, extension at the atlanto-occiptal joint and a horizontal level between the tragus of the ear and sternum. The theoretical purpose of this position is to improve the glottic visualisation by aligning the oral, pharyngeal and tracheal axes.

In recent years with the advancement of technology, videolaryngoscopy has become popular and many centres are now using only videolaryngoscopes for tracheal intubation. Visualisation occurs indirectly through fibreoptic or digital channels. Most videolaryngoscopes use two types of blades. The Macintosh type for normal airway and hyper-angulated blade for difficult airway.

Hyperangulated blades such as the Glidescope LoPro (Verathon Inc, Bothwell, WA, USA), McGrath Series 5 X blade (Medtronic, Minneapolis, MN, USA) and Storz C-Mac D-blade (Karl Storz Endoscoke, Tuttlingen, Germany) are more curved than the traditional standard geometry used with direct laryngoscopy and are thought to improve glottis visualisation without significant change in head position. However, visualisation of glottis is one of the three steps involved in videolaryngoscopy assisted tracheal intubation. The other two steps include aligning the tube with the glottic inlet and advancing the tube through the glottis into the trachea.

One of the main drawbacks in videolaryngoscopy is that despite good view of glottis on the screen, it can be difficult to successfully advance the tracheal tube into the trachea. Anterior impingement of the tracheal tube at the sub-glottic region is a recognised problem with hyperangulated and channelled videolaryngoscopes. VL directs the pre-formed tracheal tube anteriorly but the trachea descends posteriorly into the thorax creating an acute angle impeding passage of the tube. This can result in difficult intubation or a failed intubation. Manoeuvres such as tube rotation and rotation of bougie can rectify this problem to some extent.

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Basic Science
盲法
None

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Able to provide consent
  • Volunteers, UHCW staff, aged > 18 years
  • Medically able and willing undertake MRI scanning.
  • Should pass the MRI safety check list to enter the MRI suite. All participants will complete an MR safety questionnaire immediately prior to their MR scan

排除标准

  • Unable to provide consent
  • Not willing to have MRI scan or unable to undergo MRI scanning
  • Known difficult intubation, Restricted or neck extension not possible or presence of arthritis of cervical spine.
  • For MRI safety reasons all participants with a cardiac pacemaker or other electronic implants will be excluded from the study.

结局指标

主要结局

Angle A Measured on MRI

时间窗: Each subject will undergo 3 MRI scans. Angle A will be measured on each scan at the end of all the scans performed that day. The angles will be measured by 2 investigators.

To determine which patient head and neck positioning significantly improves the angle A. It is defined as the angle between the tracheal axis (TA) and laryngeal axis (LA)

次要结局

  • Angle B, C, D and E Measured Using MRI(Each subject will undergo 3 MRI scans. The angles will be measured on each scan at the end of the scanning performed that day. The angles will be measured by 2 investigators.)

研究者

申办方类型
Other
责任方
Sponsor

研究点 (2)

Loading locations...

相似试验