跳至主要内容
临床试验/NCT04068545
NCT04068545已完成不适用

Experiences With New Digital Surgical Drainage System in Thoracic Surgery

Centese, Inc.1 个研究点 分布在 1 个国家目标入组 30 人开始时间: 2019年9月2日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
发起方
Centese, Inc.
入组人数
30
试验地点
1
主要终点
Device User Experience Survey

研究概览

简要总结

The purpose of this study is to evaluate the Thoraguard Surgical Drainage System in a real-world clinical environment. It is believed that this system will offer functional and clinical benefits over the current standard of care system for the removal of surgical fluids and air following thoracic surgery. Observations, experiences, and outcomes in a single hospital setting will be collected for the Thoraguard Surgical Drainage System.

详细描述

The Thoraguard System is intended for use for drainage of blood, fluids, and gases following cardiac and thoracic surgery. The system consists of an electronic control module and drainage kit (fluid collection canister and drainage line) which connect to a proprietary chest tube but may also connect to other thoracic drainage catheters. The system continuously monitors line patency, automatically clears the chest tube (when used with Thoraguard Chest Tube) and drainage line from build-up, and provides digital readings of fluid output trends. The system is battery powered with integrated suction for ease of ambulation.

Additionally, the system has patient safety alarms to notify clinical staff of unexpected events associated with postoperative drainage. These functions offer significant improvements over the current standard of care. Reliable post-operative drainage, reduced workload, and decreased variability in chest tube maintenance procedures have the potential to increase patient safety, reduce complications, and improve the patient experience.

研究设计

研究类型
Observational
观察模型
Cohort
时间视角
Prospective

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Adult (age ≥ 18)
  • Patient undergoing non-emergent thoracic surgery (Sternotomy, Video-Assisted Thoracoscopic Surgery (VATS), Thoracotomy, or Robotic)
  • Expected requirement for chest drain monitoring of air leak for at least 24h post-operation
  • A requirement for a surgical drainage system

排除标准

  • Emergency surgery
  • Re-do surgery
  • Prior thoracic surgery
  • Transplant Surgery
  • In the opinion of the investigator, the patient is unsuitable for the study for any other legitimate reason including incarceration, pre-existing medical or psychiatric condition, or interfering medications
  • Known previous or concurrent enrollment in a clinical trial that, in the opinion of the investigator, might interfere with the objectives of this clinical trial
  • Pregnancy

结局指标

主要结局

Device User Experience Survey

时间窗: At study completion - approximate 6 months.

The Device User Experience Survey is an unvalidated, Sponsor-generated questionnaire aimed to increase the Sponsor's understanding of the usability of the Thoraguard Surgical Drainage System. The questionnaire asks approximately 15 questions (includes yes/no responses, rating scales, and fill-in-the-blank sections) and is to be completed by the treating clinicians at the completion of the study. A summary of all treating clinician responses will be generated at the completion of the study to summarize the overall user experience with the device.

次要结局

未报告次要终点

研究者

发起方
Centese, Inc.
申办方类型
Industry
责任方
Sponsor

研究点 (1)

Loading locations...

相似试验

Experiences With New Digital Surgical Drainage... | 临床试验