跳至主要内容
临床试验/NCT06451718
NCT06451718招募中不适用

First in Human Study to Assess the Safety and Efficacy of an Implantable Nitinol Device in the Treatment of Stage 3 and 4 Keratoconus (KC)

Fundacio De Recerca Del Instituto De Microcirugia Ocular2 个研究点 分布在 1 个国家目标入组 12 人开始时间: 2024年5月7日最近更新:
适应症

试验速览

阶段
不适用
状态
招募中
发起方
入组人数
12
试验地点
2
主要终点
Best Distance Spectacle Corrected Visual Acuity (BDSCVA)

研究概览

简要总结

This Study is a first in human clinical study addressed to evaluate the safety and efficacy of a novel intra-corneal nitinol device (Investigational Device; GROSSO® implant) for the treatment of advanced keratoconus disease of the eye.

详细描述

The medical device under investigation is a sterile thin 8-mm diameter circular scaffold made of a nickel-titanium alloy (nitinol) that is intended as a permanent implant that is surgically inserted into the cornea in order to modify force by inducing a change in corneal shape and consequently improving vision. This Study is aimed at adults with a stage 3-4 keratoconus, a central K reading > 53.00 D and RMS of coma aberration > 3.5, which are not eligible for Intrastromal Corneal Ring Segments (ICRS) and are recommended for keratoplasty.

Therefore, this study represents a salvage route to preserve the cornea. Envisaged worst case scenario of failure of the experimental device patients would be redirected to keratoplasty.

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Treatment
盲法
None

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Male and female ≥ 18 years old
  • Not suitable for ICRS and are recommended for keratoplasty
  • Best distance spectacle corrected visual acuity (BDCSVA) 1.30 - 0.40 logMAR (0.05-0,40 decimal notation)
  • Have stable or stabilized disease for 12 months (in case of cross-linking, it must have been done 12 months prior to intervention)
  • Have a KC stage 3-4 (Amsler-Krumeich) with a Central K readings > 53.00 D and RMS of coma aberration > 3.
  • Signed and dated informed consent form

排除标准

  • Inability of patient and/or relatives to understand the clinical investigation procedures and thus inability to give informed consent
  • Untreated progressive KC
  • Single functioning eye
  • Minimum Corneal thickness < 400 μm
  • Other ocular diseases (eyelids malposition, uveitis, ocular hypertension, glaucoma, cataract, retinal disorders) or corneal surgeries (refractive corneal surgery, keratoplasty), except corneal crosslinking
  • Systemic collagenopathies and/or vasculitis, and other diseases that in the opinion of the principal investigator may be contraindicated

结局指标

主要结局

Best Distance Spectacle Corrected Visual Acuity (BDSCVA)

时间窗: 6 month follow up

Changes in BDSCVA

Corrected IOP (bIOP) assessments

时间窗: 6 months follow up

Changes in bIOP

Macular central thickness assessments

时间窗: 6 months follow up

Changes in macular central thickness

Incidence of Treatment-Emergent adverse events , classification and related severity

时间窗: 6 months follow up

Assessments, classification and related severity of Serious Adverse Device Effects (SADE), Adverse Events (AE) and Serious Adverse Events (SAE) and

Slit lamp corneal assessment. Observations will be graded as follows:0- Absence 1- Mild 2- Moderate 3- Severe

时间窗: 6 months follow up

Corneal inflammation Corneal infection Corneal neovascularization Corneal stromal lysis Corneal melting Corneal stromal infiltration Corneal neo vessels Persistent corneal epithelial defects

Epithelial corneal thickness assessments

时间窗: 6 months follow up

Changes in total and epithelial corneal thickness (central and minimum)

Intraocular pressure (IOP) assessments

时间窗: 6 months follow up

Changes in IOP

Subjective numeric scale related to several ocular symptoms, graded from 0 to 10. lower scores reflect better symptomatology outcome

时间窗: 6 month follow up

Subjective numeric scale elated to pain, foreign body sensation, tearing, photophobia, glare and halos.

Corneal endothelium assessments

时间窗: 6 months follow up

Change in the number of cells/mm\^2 in the corneal endothelium

次要结局

  • Measurement of topographic keratometry values(6 month follow up)
  • Measurement of topographic astigmatism(6 month follow up)
  • Measurement of refractive astigmatism(6 month follow up)
  • Assessment of the centration of the intracorneal implant(6 month follow up)
  • Best Corrected Visual Acuity(BCVA) with rigid gas permeable(RGP) contact lens (RGP-BCVA)(6 month follow up)
  • Measurement of manifest refraction sphere equivalent (MRSE)(6 month follow up)
  • Measurement of irregularity index (IR)(6 month follow up)
  • Measurement of Uncorrected Visual Acuity (UCVA)(6 month follow up)
  • Measurement of Optical surface index (OSI) related to Optical Quality(6 month follow up)
  • Measurement of Root Mean Square (RMS) related to Optical Quality(6 month follow up)
  • Assessment of the corneal applanation(6 month follow up)
  • Measurement of biomechanical properties and characterization of the cornea by measuring Deflection Amplitude Ratio (DAR: Deflection Amplitude Ratio)(6 month follow up)
  • Measurement of biomechanical properties and characterization of the cornea by measuring Stiffness Parameter-A1 (SP-A1) and Stress-Strain Index (SSI)(6 month follow up)
  • Measurement of vision Related Quality of Life (VRQoL)(6 month follow up)
  • Measurement of biomechanical properties and characterization of the cornea by measuring ,Integrated Radius(6 month follow up)
  • Measurement of biomechanical properties and characterization of the cornea by measuring, Ambrósio Relational Thickness horizontal (ARTh)(6 month follow up)
  • Measurement of biomechanical properties and characterization of the cornea by measuring Stress-Strain Index (SSI)(6 month follow up)

研究者

发起方
Fundacio De Recerca Del Instituto De Microcirugia Ocular
申办方类型
Other
责任方
Sponsor

研究点 (2)