跳至主要内容
临床试验/NCT04668742
NCT04668742已完成不适用

A Clinical, Controlled, Randomized Trial to Evaluate the Efficacy and Safety of the New Dynatraq Invention Device to Prevent Complications Associated With Tracheostomy Tubes in Mechanically Ventilated Patients: " Dynatraq-2 Study "

Fundación Cardiovascular de Colombia2 个研究点 分布在 1 个国家目标入组 74 人开始时间: 2019年11月25日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
74
试验地点
2
主要终点
Presence of mis-alignment of tracheostomy tube

研究概览

简要总结

Although tracheostomy is a common technique in Intensive Care Units (ICU), its complications can be frequent (between 5% to 40%). Inadequate fixation could favor decannulation, as well as incorrect alignment of the tracheostomy with respect to the tracheal axis could favor the appearance of tissue alterations such as ulcers, bleeding or fistulas, as well as obstruction of the ventilatory obstruction. Having a device that is effective in fixation and alignment could help in reducing tracheostomy complications, so this study aims to evaluate the effect and safety of a fixation device for tracheostomy through a randomized clinical trial.

详细描述

Introduction

Tracheostomy is one of the most frequently required surgical techniques for the management of hospitalized patients in Intensive Care Units (ICU). This procedure is justified to facilitate the improvement of the patient, facilitate early rehabilitation, reduce sedation and analgesia requirements, and reduce the length of stay in the ICU and the days of mechanical ventilation (MV). However, tracheostomy is associated with various complications, from mispositioning and accidental decannulation, to hemoptysis, tracheal fistulas, air leaks, and ventilatory difficulties. In a pre-post quasi-experimental study where the effect of the DYNAtraq technological innovation device on tracheostomy fixation and alignment was evaluated, it was found that it can correct 83% of cases, which contrasts with only 2% when they did not have the device. (p <0.01). This previous study allowed us to conclude that technological innovation through DYNAtraq is pertinent, relevant and effective to correct the position of tracheostomy tubes in patients hospitalized in the ICU and under mechanical ventilation.

Objective

To evaluate the efficacy and safety of the DYNAtraq medical device to keep tracheostomy tubes in correct alignment and fixation in adult patients with tracheostomy hospitalized in the ICU and under invasive mechanical ventilation.

Methodology: Randomized, controlled clinical trial (two-parallel arm), assigned in a 1: 1 ratio, in a sample of 74 patients mechanically ventilated in intensive care unit (37 in intervention group and 37 patients in control group). This study is conducted in two centers for intensive care patients in two Colombian cities and

The patients randomized to the intervention group will have the external fixation system for the tracheostomy installed, which is a non-invasive plastic device, from the start of the tracheostomy to ventilatory weaning. Patients in the control group will receive the usual management of the tracheostomy given in ICU. To evaluate alignment , the cephalo-caudal (C-C) and lateral-lateral (L-L) angles will be evaluated through photographs and analyzed with the SAPO application. The mean values of the angles were obtained in degrees and their 95% confidence intervals. Angular means were compared using the paired Student's t test.

Expected Results: The DYNAtraq device is expected to be effective in improving the proper fixation, orientation, and alignment of the tracheostomy tube in mechanically ventilated patients, reducing the complications of lacerations, bleeding, decannulation, and respiratory infectious complications.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Supportive Care
盲法
Single (Investigator)

盲法说明

masking of the intervention and control groups in the statistical analysis of the data, which will be represented as group 0 and 1, without identifying whether they are control or intervention

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • 18 years of age
  • Indication for a tracheostomy
  • Signature of informed consent

排除标准

  • Mediastinitis
  • Open chest
  • Chest skin infection /burns anterior region of the thorax
  • Patients requiring reanimation
  • Active phase of COVID-19

结局指标

主要结局

Presence of mis-alignment of tracheostomy tube

时间窗: 72 hours after tracheostomy installation

Deviation from 95° angle of tracheostomy tube (cephalo-caudal (C-C) and lateral-lateral (L-L) angles) No evidence of alignment of tube though bronchoscopy

次要结局

  • Presence of complications of tracheostomy(72 hours after tracheostomy installation)