Breaking Disparities in Access to Advanced Diabetes Technologies in Children With Type 1 Diabetes

Recruiting
Conditions
Child
Delivery of Health Care
Equipment and Supplies
Diabetes Mellitus, Type 1
Interventions
Device: Advanced artificial pancreas closed-loop technology
Registration Number
NCT05849753
Lead Sponsor
Nemours Children's Clinic
Brief Summary

50 children/adolescents (ages 6 to \<18yrs) with T1D in suboptimal control (HbA1c≥8.0%) and lower SES (below 200% poverty line) on insulin therapy (either injections or open-loop pumps) will be recruited at Nemours \~ 1/3 each AA, Hispanic/Latino, non-Hispanic whites. All families that qualify and agree to transition to closed-loop technologies will be recruited to allow data to be gathered before and after use of devices. They will go through the process of approval with the assistance of an insurance navigator in clinic. Those not a CGM will be prescribed one as well. Diabetes care will be 'real life', devices will be prescribed, and care per clinic routine with periodic device downloads. Principal outcome, time-in-range, will be analyzed at 3-months compared to baseline, each participant their own control. Secondary outcomes including HbA1c, other glucose metrics and questionnaires related to use of technology and diabetes distress will be also analyzed. All outcomes will also be collected at 6-months. Results could have important and fast applicability to the field and help better inform decision makers, including payers, clinicians, and patients and families and could serve to decrease health care disparities in this needy population.

Detailed Description

Type 1 diabetes (T1D) has serious complications, yet only \~17% of children achieve an HbA1C goal of \<7.5% and in adolescents mean HbA1c remains persistently high at 9.3%. Technology use in children has increased, both insulin pump use and continuous glucose monitors (CGM), offering hope to improve diabetes control and outcomes. There are however, striking socio-economic (SES) and racial/ethnic disparities in these outcomes, with worse metabolic control and much lower use of technology in those of lower SES and racial/ethnic minorities. Reasons are multifactorial, including more limited access to care, insurance challenges, and providers' biases in prescribing these devices, but also related to implicit bias and structural racism towards minority groups. Rates of diabetes complications and ketoacidosis are higher in Black and Latino youth, yet these children are largely under-represented in clinical trials and in the clinical use of FDA-approved modern diabetes technologies. Closed-loop artificial pancreas now allows for the semi-automatic or fully automatic delivery of insulin based on CGM glucose, with potential to further improve glycemic control. The investigators' recent data suggest that patients in ethnic minority groups provided devices through a clinical trial may indeed benefit from this technology with improved time-in-range and HbA1c. Insurance companies, including Medicaid now include these FDA-approved devices in their formulary, yet they continue to be underutilized by these needy families. The investigators believe the overwhelming amount of data support the routine use of closed-loop insulin delivery technology in children. The proposed study will be first to compare use of advanced closed-loop insulin delivery systems specifically focused on children with T1D of lower SES, including racial/ethnic minorities, using patient-centered outcomes while understanding clinical markers of diabetic control. The principal study question is whether these children can benefit from a closed-loop insulin delivery treatment option and improve health care disparities in a 'real life' setting.

Specific Aims:

To investigate in children with type 1 diabetes of lower SES, including AA and Latino racial/ethnic minorities, who are in suboptimal diabetes control, if when they are consistently offered advanced artificial pancreas closed-loop technology, and are better assisted in getting approval and starting these devices clinically:

1. can health care disparities decrease by improving overall diabetes control including time-in-range sensor glucose(70-180mg/dl) (principal) and other metrics of glycemic control including HbA1c at 3 months;

2. can any clinical benefit be sustained for 6 months in a real life setting;

3. can the above treatments improve patient/family reported perceptions of quality of life, including diabetes distress and psychosocial aspects of closed-loop technology? (secondary)

Recruitment & Eligibility

Status
RECRUITING
Sex
All
Target Recruitment
50
Inclusion Criteria

Diagnosis of T1D for at least 1 year based on clinical presentation (polyuria, polydipsia, weight loss, and/or ketoacidosis, or with positive diabetes autoantibodies) on insulin, including injections or open-loop pumps

  • HbA1C ≥ 8.0% at least twice within the last 12 months before study initiation, upper limit of HbA1C <14%
  • Be of lower SES, defined based on < 200% above published US levels of poverty by family size and income, or based on exceptional circumstantial needs in the opinion of the investigators
  • Approximately 1/3 AA, 1/3 Hispanic/Latinos, 1/3 non-Hispanic whites. Asians, Pacific Islanders and other ethnic groups however will not be excluded from participation if other criteria met
  • History of hypothyroidism on adequate replacement therapy with normal thyroid function will be allowed
Read More
Exclusion Criteria
  • Severe eczema or any other skin condition that would limit availability of healthy skin to wear devices
  • Chronic medications/medical conditions that could interfere with diabetes management (ADHD medications allowed)
  • Chronic seizures, or severe neurodevelopmental delay
  • Current use of hybrid closed-loop, automated insulin delivery system
  • Significant mental health disorder that in opinion of the investigator would hinder device use
Read More

Study & Design

Study Type
OBSERVATIONAL
Study Design
Not specified
Arm && Interventions
GroupInterventionDescription
T1DM lower SESAdvanced artificial pancreas closed-loop technologyType 1 diabetes of lower SES, including AA and Latino racial/ethnic minorities, who are in suboptimal diabetes control.
Primary Outcome Measures
NameTimeMethod
Percent sensor glucose time-in-range3 months

70-180mg/dL

Secondary Outcome Measures
NameTimeMethod
HbA1C6 months

percent

Percent sensor glucose time in hypoglycemic range6 months

less than 54 mg/dL

Problem Areas in Diabetes6 months

Psychosocial questionnaire (Scale: 0-80); lower score reflects better outcome

Percent sensor glucose time-in-range6 months

70-180mg/dL

Perceptions of Benefits & Burden of Closed-Loop Systems6 months

Psychosocial questionnaire (Scale: 35-175); higher score reflects better outcome

Technology Attitudes6 months

Psychosocial questionnaire relating to diabetes technology (Scale: 5-25); higher score reflects better outcome