跳至主要内容
临床试验/NCT04698837
NCT04698837已完成不适用

AeroCOVID 1: Understanding Potential Airborne Transmission and the Protective Value of Type II Surgical Masks in SARS-CoV-2 Using Patient Proximity Environmental Sampling With a Highly Efficient Bioaerosol and Droplet Collection Dummy

Insel Gruppe AG, University Hospital Bern1 个研究点 分布在 1 个国家目标入组 30 人开始时间: 2021年2月2日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
入组人数
30
试验地点
1
主要终点
Total amount of dummy-inhaled virus copies per 30 minutes sampling per size fraction (>10 µm, <10 µm)

研究概览

简要总结

Modes of transmission of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) and specifically the proportion of airborne transmission in this infection is unknown. In the aeroCOVID study, a highly efficient bioaerosol and droplet sampling dummy is used to emulate a susceptible healthcare worker (HCW) and to perform patient proximity sampling. The dummy will measure the dummy-inhaled dose of SARS-CoV-2 in two particle size fractions in a standardized interaction with hospitalized coronavirus disease 2019 (COVID-19) patients. All measurements are performed in a masked and unmasked dummy setup in parallel, in order to gain further information on the protection of type II masks against the respective particle size exposure.

详细描述

Modes of interpersonal transmission in SARS-CoV-2 are to date only incompletely understood and require further investigation in order to define best preventive measures. Although a dichotomization of inhaled particles by particle size is an oversimplification and a large particle size does not exclude shortterm airborne behavior, the suspension time of virus containing particles and the probability of particles to accumulate in room air is primarily defined by particle size distribution. Particles with a size below 10 µm have a high probability of accumulation due to their mean suspension time of minutes to hours.

The study aims to measure the total amount of virus copies per particle size fraction inhaled by a highly efficient sampling dummy emulating a susceptible HCW in a standardized interaction with hospitalized COVID-19 patients. As a secondary endpoint, the proportion of culturable virus in each setup is measured as well.

Sampling is done in using two parallel bioaerosol and droplet sampling dummies - one type II masked and one with an unmasked dummy head as inlet - in order to gain additional information on the protective effect of type II surgical masks in a real-life exhaled particle size distribution in hospitalized COVID patients. The sampling dummy consists of a real size face relief connected to an 60° inlet cone, a cyclone for collection of particles >10 µm and a laminar flow water-based condensation bioaerosol collector for particle collection below 10 µm particle size.

After patient proximity sampling, a nasopharyngeal swab for SARS-CoV-2 polymerase chain reaction (PCR) assay is performed. Relevant indoor climate parameters like temperature, humidity and carbon dioxide (CO2) as well as room characteristics as air change rate are recorded as well.

研究设计

研究类型
Observational
观察模型
Other
时间视角
Other

入排标准

年龄范围
18 Years 至 110 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • positive SARS-CoV-2 PCR or antigen test from a nasopharyngeal or oropharyngeal swab
  • ≥18 years of age
  • ability to give consent
  • ability to follow simple instructions

排除标准

  • symptom onset more than 10 days prior to inclusion
  • pregnancy
  • lack of written informed consent

结局指标

主要结局

Total amount of dummy-inhaled virus copies per 30 minutes sampling per size fraction (>10 µm, <10 µm)

时间窗: 30 minutes sampling

次要结局

  • Reduction of dummy-inhaled virus copies per 30 minutes sampling in a type II-masked setup, as compared to unmasked, per size fraction (>10 µm, <10 µm)(30 minutes sampling)
  • Viability of dummy-inhaled viable virus per size fraction (>10 µm, and <10 µm)(30 minutes sampling)

研究者

申办方类型
Other
责任方
Sponsor

研究点 (1)

Loading locations...