MedPath

Subjective and Objective Performance With the SONNET2EAS

Not Applicable
Withdrawn
Conditions
Hearing Disability
Hearing Loss
Interventions
Device: Automatic Sound Management 3.0
Registration Number
NCT04721990
Lead Sponsor
University of North Carolina, Chapel Hill
Brief Summary

Purpose: The purpose of this study is to demonstrate the non-inferiority and new features of an external speech processor for cochlear implant recipients.

Participants: This study seeks to enroll 15 cochlear implant recipients listening to previous technology.

Procedures (methods): Subjects will be programmed and tested with old and new technology.

Detailed Description

Candidacy criteria for cochlear implantation include adults with normal-to-moderate low-frequency hearing and severe-to-profound high-frequency sensorineural hearing loss. A cochlear implant system includes two parts: 1) the internal electrode array that is surgically implanted into the cochlea, and 2) the external audio processor that picks up the acoustic signal. The external audio processor sends the converted acoustic signal to the internal device, which is presented as electrical pulses via individual electrodes and interpreted by the brain as sound.

When acoustic hearing in the implanted ear is preserved postoperatively, cochlear implant recipients are fit with an electric-acoustic stimulation (EAS) device. An EAS device combines acoustic and cochlear implant technology into a single device to provide acoustic amplification of the aidable low-frequency hearing region and electric stimulation of the mid-to-high frequency region. Cochlear implant recipients demonstrate a significant improvement when listening with EAS as compared to listening with acoustic or electric stimulation alone on measures of speech understanding and subjective benefit. The benefit is thought to be due to the addition of acoustic low-frequency cues.

The MED-EL SONNETEAS system was approved for commercial use in 2017 for adults (MED-EL, Innsbruck, Austria). Recently, the SONNET2EAS was approved and is currently MED-EL Corporation's newest EAS audio processor. While processing with the SONNET2EAS is currently the similar to that of the SONNETEAS, updated "front-end features", including improved artificial intelligence, are available within the device but have not been approved for commercial use.

Front-end processing occurs in the external audio processor prior to the coding of the signal. This processing is intended to optimize signal perception in variable environments (e.g. complex, noisy listening conditions). Currently, the SONNETEAS and SONNET2EAS have two microphones receiving the incoming signal, which are then manipulated to allow for wind noise reduction (WNR) and directional processing. These features are included within the currently approved "Automatic Sound Management (ASM) 2.0" and primarily seek to improve speech perception in the presence of noise. ASM 3.0 may offer cochlear implant listeners an improvement in speech understanding, specifically in complex or noisy listening situations, and potentially improve ease of listening in a dynamic environment. Listeners of devices with front-end processing demonstrate similar or improved performance than with devices without this technology - dependent on the listening situation.

The aim of the present investigation is to compare objective and subjective outcomes with the new front-end features to the current generation in EAS device users, using a within subject design.

Recruitment & Eligibility

Status
WITHDRAWN
Sex
All
Target Recruitment
Not specified
Inclusion Criteria
  • Adult (≥18 years at date of enrollment/initial evaluation)
  • MED-EL Cochlear Implant System recipient
  • Unilateral cochlear implant recipient
  • Unaided threshold of ≤65 decibels (dB) Hearing Level (HL) at 125 Hz in implanted ear
  • Six months or greater of SONNETEAS listening experience
  • Consistent device user, as deemed by research team
  • Minimum of 10 enabled electrodes
  • Consonant Nucleus Consonant (CNC) word score of ≥40% with SONNETEAS processor and contralateral ear plugged/masked
  • Native English speaker (as all materials are written or spoken in English)
Read More
Exclusion Criteria
  • Unaided pure tone average (500, 1000, 2000 Hz) ≤60 dB HL in the contralateral (non-implanted) ear
  • Hearing technology other than a conventional hearing aid in the contralateral ear
  • Unwilling, unable, or geographic limitations to participate in study procedures
  • Unwilling to complete datalogging with the processor
Read More

Study & Design

Study Type
INTERVENTIONAL
Study Design
SINGLE_GROUP
Arm && Interventions
GroupInterventionDescription
Automatic Sound Management 3.0Automatic Sound Management 3.0Current SONNETEAS listeners, who meet the eligibility criteria, will be tested with their current listening configuration and also fit with a SONNET2EAS, programmed with Automatic Sound Management 3.0 (under the Investigational Device Exemption).
Primary Outcome Measures
NameTimeMethod
Difference in reported subjective benefit on the Spatial Domain of the Speech, Spatial and Qualities of Hearing (SSQ)2 Years

Participants reported subjective device benefit for the directional, distance, and movement components of spatial hearing by marking on a visual analog scale from 0 to 10, with 0 being the minimum benefit and 10 being maximal benefit. A higher score is greater subjective benefit reported by the participant. Scores obtained with the SONNETEAS will be compared to those obtained with the SONNET2EAS, programmed with Automatic Sound Management 3.0.

Difference in reported subjective benefit on the Qualities Domain of the Speech, Spatial and Qualities of Hearing (SSQ)Up to 2 months after enrollment

Participants reported subjective device benefit in qualities of hearing (including ease of listening and the naturalness, clarity, and identifiability of different sounds) by marking on a visual analog scale from 0 to 10, with 0 being the minimum benefit and 10 being maximal benefit. A higher score is greater subjective benefit reported by the participant. Scores obtained with the SONNETEAS will be compared to those obtained with the SONNET2EAS, programmed with Automatic Sound Management 3.0.

Difference in Hearing-in-Noise-Test (HINT) Sentences in Diffuse NoiseUp to 2 months after enrollment

Testing open-set sentence understanding with background noise present. Recorded Hearing-in-Noise-Test (HINT) sentences in diffuse noise will be presented to participant. Resultant score is a percentage of words correct with a range of 0% to 100%. A higher score is better. Scores obtained with the SONNETEAS will be compared to those obtained with the SONNET2EAS, programmed with Automatic Sound Management 3.0.

Difference in Consonant-Nucleus-Consonant (CNC) Words ScoresUp to 2 months after enrollment

Testing open-set word understanding. Recorded CNC Words lists will be presented to the participant. Resultant score is a percentage of words correct with a range of 0% to 100%. A higher score is better. Scores obtained with the SONNETEAS will be compared to those obtained with the SONNET2EAS, programmed with Automatic Sound Management 3.0.

Difference in reported device satisfaction on the Audio Processor Satisfaction Questionnaire (APSQ)Up to 2 months after enrollment

Participants report subjective device satisfaction by marking on a visual analog scale from 0 to 10, with 0 being the minimum benefit and 10 being maximal benefit. A higher score is greater subjective satisfaction reported by the participant. Scores obtained with the SONNETEAS will be compared to those obtained with the SONNET2EAS, programmed with Automatic Sound Management 3.0.

Difference in reported subjective benefit on the Speech Domain of the Speech, Spatial and Qualities of Hearing (SSQ)Up to 2 months after enrollment

Participants report subjective device benefit when hearing speech in a variety of competing contexts by marking on a visual analog scale from 0 to 10, with 0 being the minimum benefit and 10 being maximal benefit. A higher score is greater subjective benefit reported by the participant. Scores obtained with the SONNETEAS will be compared to those obtained with the SONNET2EAS, programmed with Automatic Sound Management 3.0.

Secondary Outcome Measures
NameTimeMethod
Difference in Consonant-Nucleus-Consonant (CNC) Words Scores between listening with SONNET2EAS and contralateral ear plugged/masked with Artificial Intelligence (AI) Mild and AI Off.Up to 2 months after enrollment

Testing open-set word understanding. Recorded CNC Words lists will be presented to the participant. Resultant score is a percentage of words correct with a range of 0% to 100%. A higher score is better. Scores obtained with the SONNET2EAS AI Mild will be compared to those obtained with the SONNET2EAS AI Off, programmed with Automatic Sound Management 3.0.

Difference in Hearing-in-Noise-Test (HINT) sentences in diffuse noise Scores between listening with SONNET2EAS and contralateral ear with Artificial Intelligence (AI) Mild and AI Off.Up to 2 months after enrollment

Testing open-set sentence understanding with background noise present. Recorded HINT Sentences will be presented to the participant. Resultant score is a percentage of words correct with a range of 0% to 100%. A higher score is better. Scores obtained with the SONNET2EAS AI Mild will be compared to those obtained with the SONNET2EAS AI Off, programmed with Automatic Sound Management 3.0.

Difference in Consonant-Nucleus-Consonant (CNC) Words Scores between listening with SONNET2EAS and contralateral ear with Artificial Intelligence (AI) Mild and AI Off.Up to 2 months after enrollment

Testing open-set word understanding. Recorded CNC Words lists will be presented to the participant. Resultant score is a percentage of words correct with a range of 0% to 100%. A higher score is better. Scores obtained with the SONNET2EAS AI Mild will be compared to those obtained with the SONNET2EAS AI Off, programmed with Automatic Sound Management 3.0.

Difference in Hearing-in-Noise-Test (HINT) sentences in diffuse noise Scores between listening with SONNET2EAS and contralateral ear plugged/masked with Artificial Intelligence (AI) Mild and AI Off.Up to 2 months after enrollment

Testing open-set sentence understanding with background noise present. Recorded HINT Sentences will be presented to the participant. Resultant score is a percentage of words correct with a range of 0% to 100%. A higher score is better. Scores obtained with the SONNET2EAS AI Mild will be compared to those obtained with the SONNET2EAS AI Off, programmed with Automatic Sound Management 3.0.

Trial Locations

Locations (1)

University of North Carolina at Chapel Hill

🇺🇸

Chapel Hill, North Carolina, United States

© Copyright 2025. All Rights Reserved by MedPath