跳至主要内容
临床试验/NCT00258596
NCT00258596已完成3 期

Sirolimus-Eluting Stents for Chronic Total Coronary Occlusions: A Randomized Comparison of Bare Metal Stent Implantation With Sirolimus-Eluting Stent Implantation for the Treatment of Chronic Total Coronary Occlusions (PRISON II)

R&D Cardiologie4 个研究点 分布在 1 个国家目标入组 200 人开始时间: 2003年1月1日最近更新:
适应症

试验速览

阶段
3 期
状态
已完成
发起方
入组人数
200
试验地点
4
主要终点
The binary restenosis rate (defined as restenosis >50% on follow-up angiography) at six-month angiography

研究概览

简要总结

Primary intracoronary stent placement after successfully crossing chronic total occlusions (CTO) decreases the high restenosis rate at long-term follow-up compared with conventional balloon angioplasty. Several studies have shown the efficacy of sirolimus-eluting stents in selected groups of patients. Whether sirolimus-eluting stents are superior to bare metal stents in CTO is unknown. In this prospective randomized trial, bare metal stent implantation will be compared with sirolimus-eluting stent implantation for the treatment of chronic total coronary occlusions. A total of 200 patients will be followed up for 6, 12, and 24 months with angiographic follow-up at 6 months. Quantitative coronary analysis will be performed by an independent core laboratory. The primary end point is the binary angiographic restenosis and reocclusion rate at 6 month follow-up.

详细描述

Since data from the 2 landmark studies, the BENESTENT and STRESS studies, showed that coronary stenting significantly decreases restenosis as compared with conventional balloon angioplasty, this treatment modality has shown to be superior in an increasing number of indications. Percutaneous coronary intervention of chronic total occlusions (CTO), however, is still limited by high restenosis rates. Although coronary stenting using bare metal stents significantly decreases restenosis in CTO, restenosis rates still reach 32% to 55%.

In 200 patients with CTO randomized in the PRISON I study, we demonstrated a restenosis rate of 22% after bare metal stent implantation as compared with 33% after conventional balloon angioplasty. During the past few years, sirolimus (rapamycin), a cytostatic macrocyclic lactone with anti-inflammatory and antiproliferative properties, delivered from a polymer-encapsulated stent was shown to almost eliminate the risk of restenosis in selected groups of patients.

In this prospective, randomized, single-blind trial we enrolled 200 patients with chronic total occlusions: 100 were randomly assigned to receive bare metal BxVelocity™ stents, and 100 to receive sirolimus-eluting Cypher™ stents. The primary endpoint was angiographic binary restenosis rate at six months follow-up. Secondary endpoints were a composite of major adverse cardiac events, target vessel failure, in-stent and in-segment minimal lumen diameter, percentage diameter stenosis, and late luminal loss at six months follow-up. Clinical long-term follow-up will performed up till 24 months

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Treatment
盲法
Single

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Estimated duration of the chronic total coronary occlusion of at least two weeks
  • Evidence of ischemia related to the target vessel (signs of ischemia during an abnormal exercise test, defined as ST depression of at least 1.0 mm that is horizontal or down-sloping or up-sloping ST depression of at least 2.0 mm or signs of ischemia found during nuclear imaging with exercise, dobutamine or adenosine).

排除标准

  • The lesion could not be crossed
  • The use of heparin, aspirin and clopidogrel was prohibited
  • Severe renal failure (creatinine>250µmol/L)
  • Patients were unwilling or unable to complete follow-up.

结局指标

主要结局

The binary restenosis rate (defined as restenosis >50% on follow-up angiography) at six-month angiography

次要结局

  • A composite of: Major adverse cardiac events (death, myocardial infarction, and ischemia driven target lesion revascularization)
  • Target vessel failure (defined as a composite of death from cardiac causes, myocardial infarction, and ischemia-driven target-vessel revascularization) at 6 month
  • In-stent and in-segment minimal lumen diameter
  • Percentage in-stent and in-segment diameter stenosis
  • In-stent and in-segment late luminal loss at six months follow-up

研究者

发起方
R&D Cardiologie
申办方类型
Other

研究点 (4)

Loading locations...

相似试验