跳至主要内容
临床试验/NCT07421752
NCT07421752招募中不适用

Evaluation of the Accuracy of the eCential Robotics Robot in Spinal Surgery at Amiens Picardie University Hospital

Centre Hospitalier Universitaire, Amiens1 个研究点 分布在 1 个国家目标入组 45 人开始时间: 2025年11月21日最近更新:
适应症

试验速览

阶段
不适用
状态
招募中
入组人数
45
试验地点
1
主要终点
Pedicle Screw accuracy using the traditional Gertzbein-Robbins Scale

研究概览

简要总结

Spinal surgery has evolved considerably over the years, and the introduction of advanced technologies has played a crucial role in improving clinical outcomes. The use of surgical robots, such as the eCential Robotic system, has emerged as an innovative solution for optimizing the precision and safety of procedures, particularly the placement of pedicle screws in the spine.

The eCential Robotics surgical robot offers several advantages for the placement of pedicle screws in the spine. Various studies have demonstrated a significant improvement in screw accuracy and stability, reducing revision surgery rates with surgical robots. The system enables advanced preoperative planning based on three-dimensional imaging, improving understanding of the patient's specific anatomy. This study will also provide a clinical basis for the CE marking process.

The objective of this prospective study is to collect data confirming safety, performance and clinical benefits of the eCential Robotics robot when used during spine and pelvic surgeries.

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Other
盲法
None

入排标准

年龄范围
5 Years 至 —(Child, Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Patients aged 5 years or older.
  • Treated at CHU Amiens Picardie for spinal surgery requiring implantation of pedicle screws.
  • Informed consent signed by patient or legal representative and child.
  • Membership of a social security scheme.
  • Negative pregnancy test for adolescent women of childbearing age

排除标准

  • Patient managed by a practitioner with no experience of the eCential Robotics robot.
  • Patient requiring a technique without implantation of pedicle screws.
  • Patients already suffering from deterministic radiation effects
  • Pregnant, parturient or breast-feeding women.
  • Patients under guardianship or curators, under safeguard of justice or deprived under public law.

结局指标

主要结局

Pedicle Screw accuracy using the traditional Gertzbein-Robbins Scale

时间窗: 12 months

Pedicle Screw accuracy using the traditional Gertzbein-Robbins Scale. perfect intra-pedicular localization without any cortical breach (Grade A) * \< 2 mm pedicle breach (Grade B) * \< 4 mm pedicle breach (Grade C) * \< 6 mm pedicle breach (Grade D) * ≥ 6 mm pedicle breach (Grade E) Screws graded A and B are clinically acceptable, screws graded C, D, E have a significant deviation from the intended trajectory.

次要结局

  • Per-operative Complication(day 0)
  • Immediate post-operative Discharge time (days)(up to 12 months)
  • Immediate post-operative Length of hospital stay (days)(up to 12 months)
  • Per-operative Hardware or software malfunction(day 0)
  • Per-operative Intraoperative complication(day 0)
  • Immediate post-operative Adverse events(up to 12 months)
  • 9-month follow-up Adverse events(at 9 months)
  • Per-operative Blood loss (ml)(day 0)
  • Per-operative Operative time (min)(day 0)
  • Per-operative X-ray exposure dose (mGy.cm2)(day 0)

研究者

申办方类型
Other
责任方
Sponsor

研究点 (1)

Loading locations...

相似试验