跳至主要内容
临床试验/NCT04233827
NCT04233827已完成不适用

Mobile Biosensor for Measuring Vital Signs in Healthcare and Home Settings

University of California, San Diego1 个研究点 分布在 1 个国家目标入组 361 人开始时间: 2016年10月20日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
入组人数
361
试验地点
1
主要终点
Accuracy of vital signs (HR and SpO2)

研究概览

简要总结

This study will record vital signs (heart rate and blood oxygen levels) using a new cell phone integrated biosensor and compare it to routine measurements carried out in the clinics and hospital at UCSD. Cell phones will be given to a selected group of subjects for use at home and data collected.

详细描述

Maxim Vital Sign study is a 2 part, investigator initiated observational study with Maxim Integrated aimed to compare vital sign readings using 2 prototype versions of new cell phone based mobile biosensors with standard of care (SOC). Adult subjects will be recruited from UCSD outpatient clinics, AVRC clinic, emergency department (ED), and hospitals. Vital signs will be measured using cell phone based mobile biosensors and SOC.

For Phase 1, up to 800 subjects will be recruited (700 adults and up to 100 adolescents). 250 subjects (200 adults and up to 50 adolescents) will participate in phase 1a and 550 subjects (500 adults and up to 50 adolescents) will participate in phase 1b. An additional group of 30 adult subjects will be recruited from outpatient clinics for participation in phase 2.

Phase 1a:

Two identical copies of the device will be tested during the first part of phase 1 with a total of 125 subjects (100 adults and up to 25 adolescents). Each prototype version will be tested on up to 125 subjects (100 adults and 25 adolescents) and compared to readings obtained by Welch-Allyn Spot Vital Signs monitor. Data will be obtained on the usability and accuracy of the measurements with each initial prototype. Measurement particularly of SpO2 depends on accurate finger position. Current SpO2 monitors encase the finger and immobilize it in order to obtain an accurate measurement. Maxim Integrated, in collaboration with DD Studios, Carlsbad CA, and Specialists in Global Health, Encinitas CA, have developed prototypes, which will be tested to inform design flaws in future prototypes.

Phase 1b:

研究设计

研究类型
Observational
观察模型
Cohort
时间视角
Prospective

入排标准

年龄范围
13 Years 至 —(Child, Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Children (≥ 13 years old) and adult male and female subjects who provide written informed consent and assent.
  • Subjects must be willing to use the mobile device and answer questions regarding their experience.

排除标准

  • Individuals with prior or recent injury to one or both of their index fingers that would prevent or interfere with the use of Maxim biosensor.

结局指标

主要结局

Accuracy of vital signs (HR and SpO2)

时间窗: 20 minutes

The accuracy of the vital sign (HR and SpO2) readings collected by Maxim biosensor compared to standard of care Welch-Allyn Spot Vital Sign monitor.

次要结局

未报告次要终点

研究者

申办方类型
Other
责任方
Principal Investigator
主要研究者

Sara H. Browne, MD, MPH

Professor

University of California, San Diego

研究点 (1)

Loading locations...

相似试验