Safety and Feasibility of ActivSightTM Laser Speckle Imaging in Visualization of Tissue Perfusion and Vasculature in Human
试验速览
- 阶段
- 不适用
- 状态
- Enrolling By Invitation
- 入组人数
- 67
- 试验地点
- 6
- 主要终点
- Preparation time of ActivSightTM.
研究概览
简要总结
ActivSightTM combines an innovative form factor and proprietary software to deliver precise, objective, real-time visualization of blood flow and tissue perfusion intraoperatively for laparoscope-based surgery. A small adaptor that fits between any existing laparoscope and camera systems and a separate light source placed along any current commercial system will deliver objective real-time tissue perfusion and blood flow information intraoperatively.
Primary Objective: To determine safety and feasibility of ActivSightTM in displaying tissue perfusion in intestinal anastomoses including colorectal and bariatric surgery.
Secondary Objective: To determine the efficacy of ActivSightTM in; (1) displaying tissue vascularity and perfusion in comparison to indocyanine green (ICG) during gastrointestinal anastomoses; and (2) displaying biliary tree during laparoscopic cholecystectomy using ICG-based intraoperative cholangiography (IOC).
详细描述
Design:
- This is a feasibility study designed to evaluate safety and feasibility of ActivSightTM in gastrointestinal anastomoses and cholecystectomy.
- Safety will be determined through clinical assessments and evaluation of any adverse event.
- Feasibility will be determined through technically successful completion of intended visualization.
- Assessment of preliminary efficacy will be performed through analysis of any intraoperative decisions made based on visual display as compared to standard endoscopic approach, or non-inferiority to ICG-based visualization and usability.
- Patients outcome and follow up to Postoperative day 28 will be monitored for clinical outcome.
- Target enrollment for the assessment of 80 patients; 52 evaluating intestinal anastomoses cases (including bariatric and colorectal cases); and 28 evaluating laparoscopic cholecystectomy. Stopping rules are triggered following the first 6 patients and a comparison group 6 patients in ICG-based treatment.
研究设计
- 研究类型
- Interventional
- 分配方式
- Na
- 干预模型
- Single Group
- 主要目的
- Device Feasibility
- 盲法
- None
入排标准
- 年龄范围
- 18 Years 至 —(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 是
入选标准
- •All patients age >= 18 years old undergoing laparoscopic or robot assisted intestinal anastomoses, or all patients age >= 18 years old who are planned for laparoscopic cholecystectomy; spoken command and literacy in the native language spoken at each participating center; ability to understand and follow study procedures; and having provided signed consent.
- •Diagnosis:
- •All patients with a clinical suspicion and diagnosis of benign or malignant, small or large bowel lesions requiring surgical resection.
- •All patients with clinical suspicion and diagnosis of symptomatic cholelithiasis or cholecystitis planned for cholecystectomy.
- •Typical imaging as per standard workup findings including US, CT and/or MRI. Plain radiographs and contrast imaging may be obtained by referring physicians and are helpful for confirming the clinical diagnosis.
- •Any bariatric patients undergoing gastric sleeve or bypass.
- •Any pediatric patient undergoing laparotomy for necrotizing enterocolitis
- •Location of pathology or resected segment:
- •Target lesions can be located in any fore-, mid- or hindgut segments requiring reconstruction and anastomoses.
- •Prior therapy:
- •Patients with prior surgery are eligible for enrollment.
- •Laboratory:
- •Hemoglobin > 9 g/dL
- •Platelet count ≥75,000/μL (may receive transfusions)
- •Normal prothrombin time, tested prothrombin, and international normalized ratio < 1.5 x upper limit of normal (ULN) (including patients on prophylactic anticoagulation)
- •Renal function: Age-adjusted normal serum creatinine derived from Schwartz formula for estimating glomerular filtration rate by the Centers for Disease Control (CDC) or a creatinine clearance ≥60 mL/min/1.73 m2 for safe
- •Adequate pulmonary function: Defined as no dyspnea at rest, and a pulse oximetry >94% on room air if there is clinical indication for determination.
排除标准
- •There is no exclusion criteria for ActivSightTM for gastrointestinal resection.
- •Patients assigned to FDA cleared ICG-based visualization are contraindicated for any chronic renal dysfunction, potential drug interaction, history of allergy to ICG or anaphylaxis, and pregnancy.
- •Patients eligible for cholecystectomy, exclusion criteria include known allergy to iodides; known history of cholangitis, pancreatitis, prior common bile duct injury, coagulopathy or known, preexisting liver disease; pregnancy or breast-feeding; or being of reproductive age with pregnancy possible and not ruled out.
- •Patients currently in any investigational agents.
研究组 & 干预措施
ActivSight Group
Patients undergoing intestinal anastomoses (colorectal and bariatric) with ActivSight (n=52) Patients undergoing cholecystectomy with ActivSight (n=28)
干预措施: ActivSight (Device)
结局指标
主要结局
Preparation time of ActivSightTM.
时间窗: 1 day
Rate on a scale of 1-5 (1 = Difficult to use or Unsatisfied - 5 = no training required or very satisfied): How easy was ActivSight to set up?
Support personnel satisfaction with ActivSightTM, as quantified by Likert scale.
时间窗: 1 day
Likert scale ratings will serve as an outcome for feasibility. Scale 1-5 question (1=strongly disagree, 2=slightly disagree, 3=neutral, 4=slightly agree, 5=strongly agree): "ActivSightTM was easy to set up for the procedure."
Latency of display of ActivSightTM.
时间窗: 1 day
Rate on a scale of 1-5 (1 = Difficult to use or Unsatisfied - 5 = no training required or very satisfied): How specifically did ActivSight display the intended field and the target tissue of interest?
Incidence of Adverse Events in 28 days following use of ActivSightTM
时间窗: 28 days
To determine safety of ActivSightTM in patients undergoing intestinal anastomoses, as defined through clinical assessments and evaluation of use related adverse events intraoperatively and a routine follow up at 28 days following surgery. ActivSightTM will be deemed safe if hardware (adaptor or light source)-related major (serious) adverse event is encountered in the treated patients and if less than 2 hardware-related minor adverse events are encountered. Adverse events will be summarized descriptively and tabulations on the type, severity, and relationship to application will be performed and any changes of outcomes from baseline on follow up will be examined using the nonparametric Wilcoxon rank test.
Resolution of display of ActivSightTM.
时间窗: 1 day
Rate on a scale of 1-5 (1 = Difficult to use or Unsatisfied - 5 = no training required or very satisfied): How was the display quality of ActivSight on the intended field and target tissue of interest?
Specificity of display of ActivSightTM.
时间窗: 1 day
Specificity of display will serve as an outcome for feasibility. Yes/No question for surgeon: "Does the perfusion information displayed by ActivSightTM reflect the expected pattern of blood flow interruption?"
Usability of ActivSightTM by surgeon, as quantified by Likert scale.
时间窗: 1 day
Likert scale ratings will serve as an outcome for feasibility. Scale 1-5 question (1=strongly disagree, 2=slightly disagree, 3=neutral, 4=slightly agree, 5=strongly agree): "ActivSightTM was easy to use while operating."
次要结局
- Ability of ActivSightTM to display biliary tree.(1 day)
- Ability of ActivSightTM to display perfusion.(1 day)
- Ability of ActivSightTM to display blood vessels.(1 day)