Study to Assess Clearances and Bio-compatibility of ELISIO Dialyzer

Phase 4
Completed
Conditions
Chronic Kidney Disease
Interventions
Device: ELISIO dialyzer
Device: Fresenius FX100 dialyzer
Registration Number
NCT01042327
Lead Sponsor
Royal Free Hampstead NHS Trust
Brief Summary

Today, haemodialysis is a recognized standard treatment for patients with chronic kidney disease stage 5. During the haemodialysis treatment session, blood passes from the patient through the extracorporeal circuit and is then returned. The dialyzer represents the greatest surface are of the extracorporeal circuit, as dialysis treatment is essentially based on the removal of small molecular weight solutes down along a concentration gradient, and this depends upon surface area. The ELISIO-H dialyzer differs in design to our current standard dialyzer, the FX100, by having fibers of a greater internal diameter, which potentially allows more internal haemofiltration, leading to an improved clearance of larger molecular weight solutes. It is now thought that these so called "middle molecular weight" solutes are more important in contributing to the clinical condition termed azotaemia, rather than smaller solutes such as urea.

The investigators therefore wish to study the clearance of middle sized molecules between the different dialyzers.

Detailed Description

Stable chronic kidney dialysis patients, currently dialyzing on the main Royal Free hospital dialysis unit will be asked to participate in the study. It is aimed to recruit 15 patients currently dialysing using the Fresenius FX100 dialyzer, who have used Fresenius polysulphone membranes for \> 3 months.

During a mid week dialysis session, dialysis adequacy will be assessed by on line clearance, and samples of both blood and dialysate taken to assess, both clearances and bio-compatibility.

Thereafter patients would be switched to dialyse using the ELISIOTM-H dialyzer, but continue with the same dialysis prescription, and after 3 months, measurements repeated

Assessments Primary Clearances : on-line Kt/V, dual pool Kt/V, phosphate, b2microglobulin, cystatin C Secondary Serum :isoprostane generation complement activation platelet activation - coagulation activation - thrombophilic markers - Other Anticoagulation requirements \& clotted circuits erythropoietin requirements, phosphate control therapy CRP

Recruitment & Eligibility

Status
COMPLETED
Sex
All
Target Recruitment
15
Inclusion Criteria
  • 15 adult patients currently dialysing using the Fresenius FX100 dialyzer, who have used Fresenius polysulphone membranes for > 3 months, who are stable and able to provide informed consent.
Exclusion Criteria
  • using other dialyzers, unable to provide informed consent, unstable on dialysis or have problematical vascular access

Study & Design

Study Type
INTERVENTIONAL
Study Design
SINGLE_GROUP
Arm && Interventions
GroupInterventionDescription
dialyzer comparisonFresenius FX100 dialyzerStable chronic kidney dialysis patients, currently dialyzing on the main Royal Free hospital dialysis unit will be asked to participate in the study. It is aimed to recruit 15 patients currently dialysing using the Fresenius FX100 dialyzer, who have used Fresenius polysulphone membranes for \> 3 months. During a mid week dialysis session, dialysis adequacy will be assessed by on line clearance, and samples of both blood and dialysate taken to assess, both clearances and bio-compatibility. Thereafter patients would be switched to dialyse using the ELISIOTM-H dialyzer, but continue with the same dialysis prescription, and after 3 months, measurements repeated
dialyzer comparisonELISIO dialyzerStable chronic kidney dialysis patients, currently dialyzing on the main Royal Free hospital dialysis unit will be asked to participate in the study. It is aimed to recruit 15 patients currently dialysing using the Fresenius FX100 dialyzer, who have used Fresenius polysulphone membranes for \> 3 months. During a mid week dialysis session, dialysis adequacy will be assessed by on line clearance, and samples of both blood and dialysate taken to assess, both clearances and bio-compatibility. Thereafter patients would be switched to dialyse using the ELISIOTM-H dialyzer, but continue with the same dialysis prescription, and after 3 months, measurements repeated
Primary Outcome Measures
NameTimeMethod
solute clearances9 months
Secondary Outcome Measures
NameTimeMethod
erythropoietin requirements9 months
effect on inflammatory markers9 months
clotting potential9 months