Descriptive in Vivo Study of Evaluating the Motor Function of Recurrent Laryngeal Nerve's Extralaryngeal Branching Electromyographically.
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 发起方
- 入组人数
- 337
- 主要终点
- The evoked EMG potentials of the branches of the recurrent laryngeal nerves as microvolt, by intraoperative neuromonitoring.
研究概览
简要总结
The investigators hypothesized that, sometimes the posterior branch of the recurrent laryngeal nerve may also have motor function. The investigators aimed to evaluate motor function of the branches in the branching recurrent laryngeal nerves in this study.
详细描述
This study group consisted of consecutive patients, undergoing thyroid and parathyroid surgery with IONM. Both anterior and posterior branches of the recurrent laryngeal nerves were assessed separately by both electromyography endotracheal tube for adduction and finger palpation for detection of laryngeal twitch due to posterior cricoarytenoid abduction. The recurrent laryngeal nerves having motor function only in the anterior branches were defined as group 1, whereas the nerves having motor function both in the anterior and posterior branches were as group 2.
研究设计
- 研究类型
- Interventional
- 分配方式
- Non Randomized
- 干预模型
- Crossover
- 主要目的
- Basic Science
- 盲法
- None
入排标准
- 年龄范围
- 18 Years 至 80 Years(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •Patients who underwent parathyroid/thyroid surgery with intraoperative neuromonitoring ,
- •Patients who had normal vocal cord functions preoperatively. -
排除标准
- •Preoperative recurrent laryngeal nerve palsy,
- •Intentional nerve transection because of cancer invasion,
- •Assessment failure of recurrent laryngeal nerve function due to the deficiency of the intraoperative neuromonitoring equipment,.
- •Parathyroidectomy operations that recurrent laryngeal nerves were not fully dissected.
结局指标
主要结局
The evoked EMG potentials of the branches of the recurrent laryngeal nerves as microvolt, by intraoperative neuromonitoring.
时间窗: intraoperative
The nerves , due to having motor functions whether on their anterior or posterior branches, were divided into two groups. The amplitudes of the anterior and posterior branches within the group 2 were compared.
次要结局
- The diameters of the branches of the recurrent laryngeal nerves.(intraoperative)
- The branching distances of the recurrent laryngeal nerves.(intraoperative)
研究者
Mehmet Uludag
Associated Professor