Comparsion of WT and SNP Techniques of EUS-FNB in Pancreatic Solid Mass (WESP-PSM)
- Conditions
- Pancreatic NeoplasmsDiagnoses Disease
- Interventions
- Procedure: wet suctionProcedure: standard negative pressure suction
- Registration Number
- NCT04605042
- Lead Sponsor
- Ruijin Hospital
- Brief Summary
The purpose of this study is to compare the diagnosis accuracy between of wet suction (WS) technique and standard negative pressure (SNP) technique in EUS-FNB by 22G EUS Procore fine needle biopsy(FNB)device for solid pancreatic lesions.
- Detailed Description
This is a multi-center, single-blind, randomized, controlled trial. two hundred and ninety six patients with solid pancreatic lesions referred for EUS guided fine needle biopsy will be randomly assigned to two groups. For group A which will be used with 22G EUS Procore fine needle biopsy device, the pass sequence is WS-SNP-WS-SNP technique. For group B with 22G EUS Procore fine needle biopsy device, the pass sequence is SNP-WS-SNP-WS. All procedures will be performed by experienced echo-endoscopists, and the patients and assessors (cytologists and pathologists) will be blinded during the entire study. The primary outcome measure is the diagnosis yield. Secondary outcome measures are specimen quality.
Recruitment & Eligibility
- Status
- UNKNOWN
- Sex
- All
- Target Recruitment
- 296
- informed consent
- Subjects over 18 years old
- Imaging examination (ultrasound, CT or MRI) diagnosed or suspected solid pancreatic mass more than 1cm
- Unable or refused to sign informed consent
- suspended anticoagulant/antiplatelet therapy
- Being pregnant or breastfeeding
- Cystic lesions of the pancreas
- coagulation disorders (PLT <50×103/ L, INR > 1.5)
- A history of mental illness
- other medical conditions that are not suitable for FNB puncture
Study & Design
- Study Type
- INTERVENTIONAL
- Study Design
- CROSSOVER
- Arm && Interventions
Group Intervention Description STANDARD first group standard negative pressure suction COOK ECHO-HD 22-C EchoTip Procore needle in SNP-WS-SNP-WS sequence STANDARD first group wet suction COOK ECHO-HD 22-C EchoTip Procore needle in SNP-WS-SNP-WS sequence WET First group standard negative pressure suction COOK ECHO-HD 22-C EchoTip Procore needle biopsy in WS-SNP-WS-SNP sequence WET First group wet suction COOK ECHO-HD 22-C EchoTip Procore needle biopsy in WS-SNP-WS-SNP sequence
- Primary Outcome Measures
Name Time Method diagnostic sensitivity of WS technique and SNP technique by EUS-FNB 6 month Sensitivity will be calculated as the probability of actually having pancreatic diasease and being diagnosed by WS technique during EUS-FNB
diagnostic specificity of WS technique and SNP technique by EUS-FNB 6 month specificity will be calculated as the probability of actually not having the pancreatic disease and being diagnosed as being free of the disease by WS or SNP technique during EUS-FNB
- Secondary Outcome Measures
Name Time Method Sample adequacy of WS technique and SNP technique by EUS-FNB 6 month The tissue integrity assessments of specimens will be evaluated by score 0-3. Score 3, sufficient material for adequate histological interpretation; Score 2, samples allowing limited histological assessment; Score 1,samples not providing histological information.
Cell density of WS technique and SNP technique by EUS-FNB 6 month The Cell density assessments of specimens will be evaluated by score A-C. Score A:Satisfactory, more than 4 clusters of cells, each cluster more than 10 cells.
Score B:Sufficient, approximately 2-4 clusters, each with more than 10 cells Score C: :Unsatisfactory, less than 2 clusters or no cells on slide