跳至主要内容
临床试验/NCT01205802
NCT01205802Unknown2 期

Prospective Study on Usability of Ringed Polytetrafluoroethylene Graft for Venous Vascular Reconstruction of Living Donor Liver Transplantation

Asan Medical Center1 个研究点 分布在 1 个国家目标入组 200 人开始时间: 2010年8月1日最近更新:
适应症
干预措施

试验速览

阶段
2 期
入组人数
200
试验地点
1
主要终点
Patency of the reconstructed MHV

研究概览

简要总结

Middle hepatic vein (MHV) reconstruction with an interposition vessel graft has been settled as a standard procedure for living donor liver transplantation (LDLT) using a right lobe graft. Increasing demand of vessel graft in the situation of limited resources of allograft led the investigators to search for new vessel substitutes. Since the use of thin-walled expanded polytetrafluoroethylene (PTFE) graft showed poor long-term patency, a prospective study is going to be performed to enhance the clinical usability of expanded PTFE graft. A clinical study intends to know how to maintain its luminal flow effectively by using ringed PTFE graft. During 12 months of study period, ringed PTFE graft will be used for reconstruction of MHV reconstruction. The investigators expect that ringed PTFE graft seems to be a more useful alternative than usual PTFE graft when adequate autologous or allogenic vessel graft is not available.

详细描述

Since late 2009, the relative supply of vessel allograft over the increasing demand on LDLT became seriously shortened in the investigators' institution. Thus the investigators decide to use prosthetic vascular grafts more frequently than before. After a preliminary study from January 2010 to July 2010, a prospective case-controlled study will be performed for 12 months from August 2010 to July 2011.

The case number of patients requiring MHV reconstruction is expected as being 200 during the study period. Of them, currently using homologous or autologous vessel grafts will be used for 150. Due to expected shortage of such human vessels, other 50 will undergo MHV reconstruction using ringed PTFE graft in addition to available autologous or homologous vessel segments.

According to the implications from precedent animal and preliminary studies, the investigators set up the institutional guidelines for use of prosthetic vascular graft during MHV reconstruction of LDLT as follows: use only ringed PTFE graft; choose graft of a larger-caliber (≥1 cm); apply an intervening patch when making an end-to-side anastomosis for MHV branch of the segment 8 (V8); provide a slight redundancy in length; make the IVC-side orifice much larger than the usual; perform flow surveillance more frequently with dynamic CT scan and Doppler ultrasonography; place a stent as soon as any significant luminal narrowing is detected; and keep hypocoagulable state for at least 2 weeks and anti-platelet therapy for 6 months.

Technical knacks for secure suture include minimal removal of the rings attached at the surface of the ringed PTFE, use of PTFE suture material (GORE-TEX SUTURE; GORE-TEX, W.L. Gore & Associated, Inc., USA) - a non-absorbable monofilament made of expanded PTFE enabling 1:1 needle to thread ratio to minimize needle hole bleeding at anastomoses, making a redundant patch plasty for end-to-side branch anastomosis especially for V8, and spray application of fibrin glues for suture-point minute bleedings and for stable fixation of PTFE graft at the liver cut surface.

The primary goal for this clinical study is set to keep up the rate of luminal patency as 100% for at least 1 month after MHV reconstruction for LDLT. Any occurrence of flow disturbance at luminal narrowing greater than 50% of the original cross-sectional area at 1 month should make the guidelines revise extensively. This protocol is designed as being a prospective case-controlled study for 1 year.

研究设计

研究类型
Interventional
分配方式
Non Randomized
干预模型
Parallel
主要目的
Treatment
盲法
None

入排标准

性别
All
接受健康志愿者
否

入选标准

  • •Living donor liver transplantation requiring MHV reconstruction

排除标准

  • •Living donor liver transplantation not requiring MHV reconstruction

研究组 & 干预措施

PTFE group

Active Comparator

MHV reconstruction with ringed Goretex

干预措施: MHV reconstruction (Procedure)

Homograft group

Placebo Comparator

MHV reconstruction with homograft

干预措施: MHV reconstruction (Procedure)

结局指标

主要结局

Patency of the reconstructed MHV

时间窗: Follow-up for 1 year

Patency rate up to 1 year

次要结局

未报告次要终点

研究者

申办方类型
Other

研究点 (1)

Loading locations...

相似试验