Transcatheter Aortic Valve Implantation With Sapien 3 Transcatheter Heart Valve for Pure Aortic Regurgitation. The S3AR Study TAVI With Sapien 3 for Pure AR.
试验速览
- 阶段
- 不适用
- 入组人数
- 50
- 试验地点
- 1
- 主要终点
- Feasibility and 30-day safety of TAVI with the SAPIEN 3 THV in patients with pure AR
研究概览
简要总结
The hypothesis is that TAVI using a SAPIEN 3 THV is feasible and safe for the treatment of pure AR.
详细描述
Up to now, the balloon-expandable valves have been considered contraindicated for patients with pure AR due to the absence of calcium which is considered necessary for the anchoring of the prosthesis. Nonetheless, several cases report have suggested the feasibility of TAVI using the SAPIEN XT THV, in patients with no calcified valves suggesting that an appropriate degree of oversizing might compensate the lack of calcium for the anchoring of these prostheses.
The new generation balloon-expandable SAPIEN 3 THV has incorporated changes in the stent frame geometry, leaflets configuration and an external sealing skirt resulting in an increased stability and outstanding control during its implantation, a greater radial force, a reduced rate of paravalvular leaks and a covering of a wider range of annulus dimensions. These characteristics of the SAPIEN 3 THV might translate into a safer use of this device in patients with pure AR and non-calcified valves.
Significant AR occurs in 2.0% of individuals of >75 years, 13.3% of patients referred for intervention, being severe in 5% of these patients. As for aortic stenosis, its prevalence increases with age and the most frequent cause is degenerative although rheumatic and endocarditis are present. Although patients with severe AR have an excess risk of mortality and aortic valve replacement reduces mortality, only 1/3 of patients with significant AR finally undergo intervention. Reasons for no intervention are unknown.
Even if it has been suggested that AR might be underestimated and the prevalence of this disease might be higher than previously reported, and a percent of patients with indication for aortic valve replacement are denied for surgery, pure AR is a small niche of patients for TAVI. In terms of cost-effectiveness, both the development of a dedicated device and the investment in the training of operators in the implantation technique might lack of interest. However, performing TAVI with a device used in the routine practice might be appealing and, importantly, safer. A preliminary case series including 3 patients have suggested the feasibility of TAVI with the SAPIEN 3 device for pure AR (Urena M, Himbert D. JACC, 2016 ). In this study we aim to evaluate the feasibility and long-term safety of the SAPIEN 3 THV in patients with pure AR.
研究设计
- 研究类型
- Observational
- 观察模型
- Cohort
- 时间视角
- Other
入排标准
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •Patients with symptomatic (at least dyspnoea NYHA class III or acute heart failure requiring hospitalisation) and pure AR
- •Contraindication or high risk for surgical aortic valve replacement
- •Echocardiography and computed tomography findings suitable for TAVI using a SAPIEN 3 THV
排除标准
- •Contraindication for TAVI (active endocarditis, aortic dissection, annuloectasia..)
- •Patients' refusal
结局指标
主要结局
Feasibility and 30-day safety of TAVI with the SAPIEN 3 THV in patients with pure AR
时间窗: 30 days
1/ Device success at 1 month follow up according to the Valve Academic Research Consortium (VARC)-2. 2-Rate of moderate or severe AR at 1-month follow-up
次要结局
- Long-term performance of TAVI with the SAPIEN 3 THV in patients with pure AR(1 year)
- Long-term safety of TAVI with the SAPIEN 3 THV in patients with pure AR(1 year)