The Reliability of a Wearable Inertial System (G-walk) on Gait and Jump Assessment in Healthy Adults.

Gazi University1 site in 1 country49 target enrollmentJune 3, 2019
ConditionsHealthyAdult

Overview

Phase
Not Applicable
Intervention
Not specified
Conditions
Healthy
Sponsor
Gazi University
Enrollment
49
Locations
1
Primary Endpoint
Jump performance
Status
Completed
Last Updated
6 years ago

Overview

Brief Summary

Gait analysis is an effective tool used for a variety of purposes, including assessing neurological diseases, risk of falling, orthopedic disability and progress during rehabilitation.The analysis of gait and jump performance must be applicable in a clinical setting. Thus; it needs to be easy to apply in a variety of life situations.The measurements should be reproducible, stable, accurate, capable of distinguishing between normal and abnormal conditions, and cost-effective. Jump measures can predict injury risks, serve as talent identification, and replicate explosive competitive activities of athletes. Furthermore, the performance in vertical jumping can be associated with neuromuscular fatigue.The purpose of this study was to confirm the test-retest reliability of the G-walk wearable sensor system for gait and jump parameters in healthy adults.

Detailed Description

The G-Walk determines spatiotemporal parameters as well as pelvic rotations during gait and allows objective and precise analysis of movements with its wearable inertial sensor. It also enables 3D kinematic analysis of the pelvis, providing a functional analysis of disorders in gait caused by neuromuscular diseases The device is placed on an elastic belt and worn on the waist of the person being evaluated, with the center of the device at the fifth lumbar vertebrae. To ensure correct placement of the device, the L4-L5 intervertebral space was palpated via the posterior superior iliac spines. After the accelerometer was placed, the participants were asked to walk calmly at normal speed, on a 10 m track, and to return to the starting position. The values and gait characteristics of acceleration in the anteroposterior and mediolateral axes were transferred to the computer software program. The tilt of the pelvis in the sagittal plane in the flexion-extension direction, the oblique displacement in the coronal plane, the angles of the rotation of movement in the transverse plane and the symmetry values of the right and left sides are obtained. While the symmetry index ranges from 0 to 100, a value closer to 100 indicates that the gait is more symmetrical Following gait assessment, Countermovement jump, static squat jump and Countermovement jump with arms thrust was measured using the device.

Registry
clinicaltrials.gov
Start Date
June 3, 2019
End Date
February 15, 2020
Last Updated
6 years ago
Study Type
Observational
Sex
All

Investigators

Responsible Party
Principal Investigator
Principal Investigator

Gokhan Yazici

Principal Investigator

Gazi University

Eligibility Criteria

Inclusion Criteria

  • Accepting to participate in the study,
  • Healthy adults,
  • Being 18-35 years old,

Exclusion Criteria

  • having any musculoskeletal, neurological or other pathology potentially affecting their gait and jump performance,
  • Refusing to participate in the study,
  • Having limited cooperation which prevents participation in the study,

Outcomes

Primary Outcomes

Jump performance

Time Frame: Reliability of the G-Walk in 7 days

The jump tests protocols included; counter movement jump , squat jump and counter movement jump with arms thrust. At the end of the jump tests, all kinematic parameters concerning the evaluated jump were provided by the software. T Each participant performed a session of three trials for each of the assessed jumps. The jump with the maximum height was accepted for analysis.

Gait Analysis

Time Frame: Reliability of the G-Walk in 7 days

Gait parameters will be assessed via the G-Walk on two separate occasions. The G-Walk is a device that is worn on the waist via an elastic belt. The G-Walk is built with a triaxial accelerometer 16 bit/axes with multiple sensitivity, a triaxial magnetometer 13 bit and a triaxial gyroscope 16 bit/axes with multiple sensitivity. This hardware is capable of acquiring and transmitting data to a computer through a Bluetooth connection and at the end of each analysis an automatic report containing the gait assessment results is ready to be analyzed. Gait symmetry values of the right and left sides are obtained within this report. While the symmetry index ranges from 0 to 100, a value closer to 100 indicates that the gait is more symmetrical.

Secondary Outcomes

  • Maximum concentric power(Reliability of the G-Walk in 7 days)
  • Peak speed(Reliability of the G-Walk in 7 days)
  • Jump height(Reliability of the G-Walk in 7 days)