跳至主要内容
临床试验/NCT02656537
NCT02656537已完成不适用

EnSite™ HD Grid Catheter Mapping System for Advanced High Density Three-Dimensional Mapping in Non-Paroxysmal Atrial Fibrillation and Atrial Tachycardia

Abbott Medical Devices11 个研究点 分布在 5 个国家目标入组 82 人开始时间: 2015年8月最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
已完成
入组人数
82
试验地点
11
主要终点
Number of subjects with adverse events associated with the use of the EnSite™ HD (High-Density)Grid Catheter mapping system.

研究概览

简要总结

In this clinical investigation, the safety, feasibility and performance of the novel EnSite™ HD Grid Catheter mapping system for advanced high-density three-dimensional mapping will be studied in patients undergoing catheter ablation procedures for the treatment of non-paroxysmal atrial fibrillation (AF) or left atrial tachycardia (AT).

详细描述

Catheter ablation for non-paroxysmal AF is more complex as triggers, if present at all, are not immediately apparent, but the abnormal atrial substrates are the likely predominant mechanisms. Additional catheter ablation strategies targeting for atrial substrate modification have been introduced. The common strategies involve either application of empirical linear lesion sets in the atrial areas or ablation of atrial areas with complex fractionated atrial electrograms in addition to pulmonary vein isolation. Nevertheless, the corresponding success rates in long-term sinus rhythm maintenance are modest.

Non-paroxysmal AF and left AT are characterized by fast and regular atrial activities, complex fractionated atrial electrograms, consistent direction of wave front propagation, and low peak-to-peak voltage. Advanced high-density three-dimensional catheter mapping strategies to target the evaluation of these characteristics and mechanisms responsible for the AF and left AT, identification of atrial areas with low peak-to-peak voltages and determination of the "critical" atrial targets for catheter ablation during the procedures would be essential.

In this clinical investigation, the safety, feasibility and performance of the novel EnSite™ HD Grid Catheter mapping system for advanced high-density three-dimensional mapping will be studied in patients undergoing catheter ablation procedures for the treatment of non-paroxysmal AF or left AT.

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Diagnostic
盲法
None

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Presence of non-paroxysmal atrial fibrillation (AF) or left atrial tachycardia (AT) referred for catheter ablation
  • Age of 18 years of age or older at time of Enrollment
  • On continuous anticoagulation (INR 2-3) for >4 weeks prior to the ablation
  • Able and willing to provide written informed consent to participate in this clinical investigation

排除标准

  • Secondary atrial fibrillation (AF)
  • Presence of a prosthetic valve(s) or hemodynamically significant valvular heart disease as determined by Study Investigator
  • Active systemic infection (e.g. sepsis)
  • Presence of left atrial thrombus (i.e., positive TEE) or myxoma, or interatrial baffle or patch via the transseptal approach
  • Contraindication to systemic anticoagulation (i.e., heparin, warfarin, or a direct thrombin inhibitor)
  • History of cerebrovascular accidents (Stroke, TIA)
  • Previous myocardial infarction, unstable angina pectoris or coronary artery by-pass <180 days at Enrollment or cardiovascular intervention expected in the 180 days post-Enrollment
  • Left atrial size >55mm
  • NYHA (New York Heart Association Classification) functional class III or IV heart failure
  • Left ventricular ejection fraction <35%
  • Uncontrolled Hyperthyroidism
  • Pregnant or of childbearing potential and not using adequate contraceptive methods or nursing
  • Participating in another clinical investigation that may confound the results of this clinical investigation
  • Life expectancy less than 12 months, as determined by Study Investigator
  • Severe clinical condition (e.g. active carcinoma) that, in the opinion of the Study Investigator, excludes the participation in the study

研究组 & 干预措施

EnSite™ HD Grid Catheter AF/AT Mapping

Experimental

干预措施: EnSite™ HD Grid Catheter mapping system (Device)

结局指标

主要结局

Number of subjects with adverse events associated with the use of the EnSite™ HD (High-Density)Grid Catheter mapping system.

时间窗: Within 48 hours from Procedure

To evaluate the safety of the novel EnSite™ HD Grid Catheter mapping system by collecting intra- and post-Procedure (within 48 hours from Procedure) adverse events.

Catheter performance during the mapping portion of the procedure

时间窗: During Procedure

To assess the HD Grid Catheter mapping system for acceptable geometry creation, map repeatability and electrogram signal quality.

Number of subjects with the electrophysiological characteristics of non-paroxysmal AF and left AT pre-catheter ablation studied using the EnSite™ HD Grid Catheter mapping system.

时间窗: During Procedure

To identify and study the electrophysiological characteristics of non-paroxysmal AF and left AT pre-catheter ablation using a novel EnSite™ HD Grid Catheter mapping system.

次要结局

未报告次要终点

研究者

申办方类型
Industry
责任方
Sponsor

研究点 (11)

Loading locations...