跳至主要内容
临床试验/NCT02300454
NCT02300454Unknown4 期

Effect of Combination of Non-sLip Element Balloon (NSE) and druG-coated bAlloon (DCB) for In-steNT Restenosis Lesions

Mitsui Memorial Hospital2 个研究点 分布在 1 个国家目标入组 210 人开始时间: 2015年6月1日最近更新:
适应症
干预措施

试验速览

阶段
4 期
入组人数
210
试验地点
2
主要终点
Angiographic in-segment late loss

研究概览

简要总结

Use of SeQuent® Please drug coated balloon (DCB) is effective to treat patients with in-stent restenosis (ISR). However, whether the type of pre-dilatation balloon prior to DCB dilatation impacts on clinical and angiographic outcomes or not is unknown. Lacrosse® Non-slip element balloon (NSE) is a balloon catheter with 3 longitudinal plastic elements which are attached to proximal and distal balloon edges. NSE is developed to incise neointimal tissue and avoid balloon slippage without vitiating balloon derivability and crossability. We investigated angiographic and clinical outcomes following normal non-compliant balloon or NSE dilatation prior to DCB dilatation in ISR lesions.This study is a single blinded, multicenter, randomized trial. Total 200 patients with ISR are randomly assigned to treat with non-compliant balloon or NSE before DCB dilatation. Optical coherence tomographic (OCT) analysis are performed before pre-dilatation and after DCB dilatation Follow-up angiography analysis are planned at 8 months in all patients. Clinical follow-up is planned at 8 and 24 months.Primary endpoint is angiographic in-segment late loss at 8 months.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Treatment
盲法
Single (Participant)

入排标准

年龄范围
20 Years 至 85 Years(Adult, Older Adult)
性别
All
接受健康志愿者
是

入选标准

  • •patients with in-stent restenosis lesions who are planned to be treated with drug coating balloon

排除标准

  • •ST elevation myocardial infarction
  • •stent thrombosis
  • •severe renal dysfunction (eGFR <30 ml/min) except dialysis
  • •pregnancy
  • •planned surgery within 3 months
  • •shock vital

研究组 & 干预措施

Non-slip element balloon (NSE)

Active Comparator

Lacrosse® NSE dilatation before use of SeQuent® Please drug coated balloon (DCB)

干预措施: Non-slip element balloon (NSE) (Device)

Balloon

Placebo Comparator

Non-compliant balloon dilatation before use of SeQuent® Please drug coated balloon (DCB)

干预措施: Balloon (Device)

结局指标

主要结局

Angiographic in-segment late loss

时间窗: 8 months

次要结局

  • DCB length(within one day)
  • the prevalence of balloon slipping(within one day)
  • angiographic minimal lumen diameter(8 months)
  • minimal lumen area (OCT analysis)(within one day)
  • mean neointimal area (OCT analysis)(within one day)
  • angiographic acute gain(within one day)
  • Target vessel failure(8 months and 24 months)
  • the prevalence of stent implantation(within one day)

研究者

申办方类型
Other
责任方
Principal Investigator
主要研究者

Jiro Aoki

Associate Director, Division of Cardiology

Mitsui Memorial Hospital

研究点 (2)

Loading locations...