Management of Patients Suspected of COVID 19 With Ultra Low Dose Thoracic Scanner

Centre Hospitalier Universitaire de Nīmes1 个研究点 分布在 1 个国家目标入组 400 人开始时间: 2020年3月5日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
400
试验地点
1
主要终点
reading of LD and ULD acquisitions

研究概览

简要总结

The year 2020 was marked by the emergence of a new respiratory disease: COVID19 related to an infection with the coronavirus SARS-CoV-2 (name given by the WHO on February 11, 2020). Initially appearing in China, in the province of Hubei, this epidemic has rapidly spread to be declared a global pandemic on March 12, 2020 by the WHO.Given the current context of the COVID-19 epidemic, strict hygiene measures have been taken in scanning rooms with systematic bio-cleaning. Strategies have been modified as a matter of urgency, with changes in the practices of electro radiology manipulators who work in "isolation" to avoid contamination. The number of scanners has increased exponentially following the curve of the epidemic, making it more and more difficult to systematically check the images before the patient leaves the room. To ensure sufficient image quality for interpretation of all scans, a complementary acquisition in ULD, with very low exposure, was systematically added to the acquisition protocol. The standard acquisition in LD, associated with this acquisition in ULD remain well below the diagnostic reference thresholds dictated by the nuclear safety authority (NRD: 350 mGy.cm. In Nîmes: LD: 100 to 150 mGy.cm and ULD: < 15 mGy.cm). These two acquisitions allow us to avoid breathing and movement artifacts, etc., without having to have the patients return for a new scan in case of a bad acquisition. This avoids an overexposure of the staff to the risk of infection by the SARS-CoV-2 virus.

The main objective of this retrospective study is to evaluate the diagnostic performance of ULD vs. LD for the accurate diagnosis of COVID-19 pneumopathy which presents a particular ground glass pattern

Our study will demonstrate that the ULD scanner can be used in the search for COVID-19 pneumopathy and thus limit the exposure of patients to X-rays, especially since thoracic scans are often repeated.

详细描述

Main objective To evaluate the diagnostic performance of ULD vs. LD scanning for the diagnosis of COVID-19 lung disease.

Primary endpoint LD and ULD acquisitions will be anonymized and randomized in a read list. Double reading of scans in a randomized and blinded manner of the results of LD and ULD acquisitions of chest scans performed for suspected COVID-19 by 2 radiologists (one junior and one senior). Scans will be classified as non-COVID and COVID. The reference will be the LD scan. In case of discrepancy, a third senior radiologist will be asked and the decision will be made by consensus.

Secondary objectives

  • Objective evaluation of image quality (signal, noise, contrast to noise ratio)
  • Subjective evaluation of image quality and confidence in interpretation.
  • Specific study of ground glass signal in ULD

Secondary evaluation criteria

研究设计

研究类型
Observational
观察模型
Case Only
时间视角
Retrospective

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Patients having had the LD and ULD acquisitions

排除标准

  • scanner not passed through the COVID circuit, no ULD acquisition performed

结局指标

主要结局

reading of LD and ULD acquisitions

时间窗: day 1

Diagnostic performance of ULD vs LD scanner for the diagnosis of COVID-19 pneumopathy

次要结局

未报告次要终点

研究者

发起方
Centre Hospitalier Universitaire de Nīmes
申办方类型
Other
责任方
Sponsor

研究点 (1)

Loading locations...

相似试验