Skip to main content
Clinical Trials/NCT00548132
NCT00548132CompletedPhase 4

Reducing Catheter-Related Bloodstream Infections in the ICU With a Chlorhexidine-Impregnated Sponge (BIOPATCH)

Washington University School of Medicine1 site in 1 country1,088 target enrollmentStarted: February 1, 2006Last updated:
Conditions
Interventions

Trial Snapshot

Phase
Phase 4
Status
Completed
Enrollment
1,088
Locations
1
Primary Endpoint
The Number of Catheter Related Bloodstream Infections (BSI) /1000 Catheter Days in Both Arms

Study Overview

Brief Summary

We proposed to perform a prospective randomized controlled trial to study the effect of the use of a commercially-available chlorhexidine-impregnated sponge (Biopatch) as part of central venous catheter care on catheter-related bloodstream infections among patients in two Barnes-Jewish Hospital ICUs.

Detailed Description

At the time of the inception of this study, there were no published randomized controlled trial on the efficacy of the Biopatch in reducing bloodstream infections. Preliminary data has shown that the Biopatch decreases colonization of the catheter exit site and thereby decrease bloodstream infections but this was at that time only theoretical.

Study Design

Study Type
Interventional
Allocation
Randomized
Intervention Model
Parallel
Primary Purpose
Treatment
Masking
None

Eligibility Criteria

Ages
18 Years to — (Adult, Older Adult)
Sex
All
Accepts Healthy Volunteers
No

Inclusion Criteria

  • •patients who are admitted to the ICU with a central venous catheter (i.e. triple lumen catheters, quadruple lumen catheters, percutaneously inserted central catheters, arterial catheters, intraaortic balloon pumps, Swan-Ganz catheters).

Exclusion Criteria

  • •patients who are not enrolled into the trial within 7 days of having the catheter being placed and patients who are allergic to chlorhexidine.

Arms & Interventions

1

No Intervention

Patients in this arm will continue to get routine care

Chlorhexidine-impregnated foam dressing

Experimental

Patient's catheters were cleaned with chlorhexidine-alcohol solution at least weekly before application of the Biopatch. These were evaluated daily and if the dressing was bloody, soiled or damaged, the dressing and the Biopatch were replaced prior to the 7-day period.

Intervention: Chlorhexidine-impregnated foam dressing (Device)

Outcomes

Primary Outcomes

The Number of Catheter Related Bloodstream Infections (BSI) /1000 Catheter Days in Both Arms

Time Frame: 2 years

The outcome measure is the number of episodes of bloodstream infections (BSI) divided by the catheter days at risk multiplied by 1000 for standardization

Secondary Outcomes

  • Clinical Sepsis Episodes/Per 1000 Catheter Days(2 years)

Investigators

Sponsor Class
Other
Responsible Party
Sponsor

Study Sites (1)

Loading locations...

Similar Trials