Evaluation of a Novel Scheimpflug Device for Detection of Early Keratoconus

Tianjin Eye Hospital1 个研究点 分布在 1 个国家目标入组 200 人开始时间: 2023年5月4日最近更新:
适应症

试验速览

阶段
不适用
状态
进行中(未招募)
入组人数
200
试验地点
1
主要终点
screening and diagnosis ability

研究概览

简要总结

Comparison of the screening and diagnosis ability of the novel Scheimpflug-based tomography device (Scansys) with Pentacam and the Scheimpflug-based biomechanics device (Corvis ST) for keratoconus.

研究设计

研究类型
Observational
观察模型
Case Control
时间视角
Prospective

入排标准

性别
All
接受健康志愿者

入选标准

  • 未提供

排除标准

  • The presence of ocular diseases other than myopia and keratoconus;
  • Ocular trauma;
  • Previous ocular surgery;
  • Patients were required to stop wearing soft contact lenses for at least 2 weeks and rigid contact lenses for at least 4 weeks before examination;
  • Pregnant and lactating women;

结局指标

主要结局

screening and diagnosis ability

时间窗: one year

Calculate the cut-off values, sensitivity and specificity of parameters measured by Pentacam, Corvis ST and Scansys in diagnosing keratoconus. Use Receiver operating characteristic curves (ROC) to analyze the optimal parameters to distinguish between the three groups.

次要结局

未报告次要终点

研究者

申办方类型
Other
责任方
Sponsor

研究点 (1)