Skip to main content
Clinical Trials/NCT06091514
NCT06091514
Not yet recruiting
Not Applicable

Connected Cardiology to Control Cardiac Rythm

Assistance Publique - Hôpitaux de Paris0 sites400 target enrollmentStarted: September 2024Last updated:

Overview

Phase
Not Applicable
Status
Not yet recruiting
Enrollment
400
Primary Endpoint
The total number of episodes AF that lasts 5 min or more recorded on long-term monitoring

Overview

Brief Summary

New-onset of atrial fibrillation (AF) and atrial arrythmia (AA) in general, is important as it exposes patients to stroke or other embolic complications not to mention the risk of heart failure. AF detection in high risk populations such as patients with a recent stroke or TIA or, symptomatic patients with multiple risk factors for AF, is performed with long-term electrocardiography monitoring using frequently implantable loop recorders (ILR). These recorders have their own limitations related to the invasive nature of the device implanted under the skin of the chest with limited acceptation by the patients. Smart watches appear as useful alternatives, but they need to be evaluated in an all-comer population of patients highly exposed to AF, different from the large population studies conducted in healthy young adults with a low incidence of AF. The unique features of CardiacSense Medical System suggest that we could have an accurate noninvasive detection of AF in a selected population very much exposed to the risk of atrial fibrillation, the most frequent atrial arrhythmia.

Detailed Description

Study design :

This clinical investigation is a comparative, non-randomised, one group, controlled study.

Each patient represents its own control. The study will envolve 400 participants

Hypothesis

Our hypothesis is that CardiacSense Medical System is an effective, safe, and better accepted alternative for detecting atrial fibrillation (AF) in a high-risk population than implantable loop recorders (ILRs).

Population :

Any patient aged 18 years or more, with an ILR implanted for the detection of AF will be eligible. The time of implantation will not matter as long as the batteries work. Each patient will be proposed a CS Medical Watch for a period corresponding to the period at risk of AF.

Main objective :

To compare the performance of the CardiacSense Medical Watch by pulse plethysmography (PPG) only to the gold standard method of ILR monitoring, to detect AF that lasts 5 minutes or more, in a population of patients at high risk of paroxysmal AF.

Study Design

Study Type
Interventional
Allocation
Na
Intervention Model
Single Group
Primary Purpose
Diagnostic
Masking
None

Eligibility Criteria

Ages
18 Years to — (Adult, Older Adult)
Sex
All
Accepts Healthy Volunteers
No

Inclusion Criteria

  • Patient aged 18 years or more
  • Patient having signed free, informed, and written consent
  • Patient presenting one of the following situations :
  • Post-stroke or TIA patient with an already in place ILR
  • Patient with symptoms evocative of AF (e.g. increased heart rate, chest pain) with an already in place ILR
  • Post-PFO closure patient with an already in place ILR
  • Patient in sinus rhythm treated for the prevention of paroxysmal AF with an already in place ILR
  • Patient at high risk of AF (at the discretion of the investigator) with an already in place ILR
  • Patient with a period of risk of AF ≥ 3 months.

Exclusion Criteria

  • Patient under legal protection
  • Pregnant and/or breastfeeding women
  • Patient with pacemakers, or ICD
  • Patient with blood flow deficiency-related conditions
  • Patient with tattoo or injured skin on the wrist
  • Patient with tremors or otherwise unable to remain still for 15 minutes
  • Patient without two hands and sufficient fingers to complete the study.

Outcomes

Primary Outcomes

The total number of episodes AF that lasts 5 min or more recorded on long-term monitoring

Time Frame: between 3 and 12 months according to the period at risk of AF

The total number of episodes AF that lasts 5 min or more recorded on long-term monitoring using the CardiacSense Medical Watch by pulse plethysmography (PPG) only vs the gold standard method of ILR ECG recording, over the same period of monitoring by the two devices for each patient.

Secondary Outcomes

  • Degree of invasiveness, comfort, and ease of use of both devices(between 3 and 12 months according to the period at risk of AF)
  • Incidence and severity of CS device vs ILR devices(between 3 and 12 months according to the period at risk of AF)
  • The total number of AA episodes that lasts 5 min or more recorded on long-term monitoring(between 3 and 12 months according to the period at risk of AF)
  • The total number of episodes AF that lasts 5 min or more recorded on long-term monitoring(between 3 and 12 months according to the period at risk of AF)
  • The total duration of AF episodes that lasts 5 min or more(between 3 and 12 months according to the period at risk of AF)
  • Medico-economic evaluation according to the AP-HP hospital costs(between 3 and 12 months according to the period at risk of AF)

Investigators

Sponsor Class
Other
Responsible Party
Sponsor

Similar Trials