A Prospective, Randomized, Multicenter Clinical Study in Elderly Chinese Subjects to Compare the Safety and Efficacy of the SS Bipolar Head and SL-TWIN Stem With Bipolar Head and SL-PLUS Stem in Hemiarthroplasty of the Hip

Smith & Nephew Orthopaedics (Beijing) Limited5 个研究点 分布在 1 个国家目标入组 134 人开始时间: 2015年4月29日最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
134
试验地点
5
主要终点
Harris Hip Score

研究概览

简要总结

This is a prospective, randomized, multicenter clinical study in elderly Chinese subjects to compare the safety and efficacy of the SS Bipolar Head and SL-TWIN Stem with Bipolar Head and SL-PLUS Stem in hemiarthroplasty of the hip

详细描述

Elderly patients, especially post-menopausal women, often suffer a femoral neck fracture due to osteoporosis, even with very little trauma. Femoral neck fracture is a common disease in elderly patients, it accounts for 3.6% of total body fractures. In China, as the population continues to age and life expectancy increases, the incidence of femoral neck fracture has significantly increased.

Hip replacement surgery includes total hip arthroplasty (THA) and hemiarthroplasty (HAP). Hemiarthroplasty of the hip involves replacement of the diseased, affected, or broken femoral head and/or neck with a prosthetic component. Hemiarthroplasty does not involve resurfacing of the acetabulum, and therefore a bipolar or unipolar prosthetic head articulates against the host acetabular articular cartilage. Avoiding the need, when appropriate, to resurface the acetabulum helps to minimize surgical trauma, operative time and dislocation risk, while preserving acetabular bone stock. These also result in shorter bed stay and faster recovery comparing with the THA.

There has been an increase in imported hip prostheses during the past decade, so that surgeons now have more choices of implants. However, the high cost of imported prostheses has become a barrier to the development of hip replacement in China and caused many patients requiring immediate hip replacement to have to delay or miss their surgery. The development and promotion of high-quality domestic joint implants and surgical instruments is the key to the development of joint replacement technique in China.

The primary objective of this study is to demonstrate non-inferiority of subjects implanted with the SS Bipolar Head + SL-TWIN Stem compared to a randomized concurrent control group of subjects implanted with the Bipolar Head + SL-PLUS Stem in terms of mean Harris Hip Score (HHS) at 1 year.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Treatment
盲法
Single (Outcomes Assessor)

入排标准

年龄范围
65 Years 至 90 Years(Older Adult)
性别
All
接受健康志愿者

入选标准

  • Male or female subjects, aged between 65 and 90 years inclusive of Chinese ethnicity.
  • Subject presents with femoral neck fracture (Garden Type II, III, or IV) requiring hemiarthroplasty of the hip.
  • Subject is able to move independently before the fracture, with or without the use of walking aids .
  • Subject who is able to give voluntary, written informed consent to participate in the study and from whom consent has been obtained by signing and dating an EC-approved consent form.
  • Subject who is able to understand this clinical study, co-operates with the investigational procedures and is willing to return to the hospital for all the required post-operative follow-ups for up to 12 months.
  • Life expectancy of subject is over 2 years.

排除标准

  • Bilateral hip disease with the anticipated need for bilateral hip implant during study participation (i.e., within the next 12 months).
  • Subject experienced prior joint replacement surgery on any major joint (hip, knee) in lower limb within the last 12 months.
  • Subject has known or suspected metal sensitivity.
  • Subject is known to have insufficient bone stock resulting from conditions such as cancer, significant osteoporosis or metabolic bone disorders, which cannot provide adequate support and/or fixation to the prosthesis.
  • Subject is severely obese (BMI>35).
  • Subject is not suitable for hemiarthroplasty (i.e., inflammatory arthritis, pathological fractures, etc.)
  • Subject had an active infection or sepsis (treated or untreated)
  • Subject has conditions that may compromise implant stability or postoperative recovery (i.e., Paget's or Charcot's disease, vascular insufficiency, muscular atrophy, uncontrolled diabetes, moderate to severe renal insufficiency, hip abduction muscle strength less than grade IV or complete loss, or neuromuscular disease).
  • Subject has an emotional or neurological condition that would affect their ability or willingness to participate in the study (e.g. cognitive disorder, mental illness, mental retardation).
  • Subject is immunosuppressed, has an autoimmune disorder, or an immunosuppressive disorder. For examples, subject is on immunosuppressive therapy (corticosteroid hormones in large amounts, cytotoxic drugs, antilymphocytic serum or irradiation in large doses) or has acquired immunodeficiency syndrome (AIDS).
  • Subject is known to be at risk for lost to follow-up, or failure to return for scheduled visits.
  • Subject was enrolled in another investigational drug, biologic, or device study in the last 12 months.
  • Known alcohol and/or drug abuse

研究组 & 干预措施

SS Bipolar Head + SL-TWIN Stem

Experimental

Subject will be implanted with the SS Bipolar Head & SL-TWIN Stem

干预措施: SS Bipolar Head + SL-TWIN Stem (Device)

Bipolar Head + SL-PLUS Stem

Active Comparator

Subject will be implanted with the Bipolar Head & SL-PLUS Stem

干预措施: Bipolar Head + SL-PLUS Stem (Device)

结局指标

主要结局

Harris Hip Score

时间窗: 1 year post-operative

次要结局

  • Composite Clinical Success, as indicated by A) No revision of any device component; and B) Total Harris Hip Score greater than or equal to 80 (excellent to good score); and C) Radiologic success.(1 year post-operative)

研究者