Occlusal Relationship Assesment of Monolithic Zirconia Fixed Dental Prosthesis
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 发起方
- 入组人数
- 14
- 试验地点
- 2
- 主要终点
- The evaluation of effectiveness of workflows by assesing the occlusal registration accuracy of 3-unit FDPs that were fabricated with two different work-flows
研究概览
简要总结
To analyze in vivo occlusal accuracy and occlusal adjustment requirement, a cross-over clinical trial was designed. Two 3-unit tooth-supported posterior FDPs were planned to be made for each patient's single missing tooth gap, one with complete analog workflow (control group) and the other complete digital workflow (test group). The analog workflow aims for a porcelain fused to metal (PFM) FDP whereas the digital workflow aims for 3-unit monolithic Zr FDP. PFor half of the restorations, digital impression was planned to be taken first and to be followed by analog impression. As for the occlusal adjustment, in half of the study sites monolithic Zr FDPs were planned to be tried-in first, followed by metal-ceramic FDP and vice versa.
One investigator (DK) was assigned to prepare the restoration sites and deliver the FDPs. All monolithic Zr and all metal-ceramic FDPs were designed and fabricated by the same experienced dental technician. One investigator (HL), that was not involved in the treatment intervention was assigned to make the 3D analysis of the volumetric occlusal adjustment amount.
详细描述
All teeth preparations will be carried out ensuring the minimum material thickness for monolithic FDPs (0.8-1 mm margin thickness, 1 mm occlusal thickness) by one experienced investigator (DK). To prevent any possible carry-over effect, the impression acquisition order will be randomized.
The control group FDPs (metal-ceramic) will be fabricated with a complete analog workflow. Accordingly, a polyether dual-phase impression (Impregum Penta Soft Quick and Soft Quick, 3M) will be taken from the restoration arch and a Polyvinylsiloxane (PVS) impression material will be used for the impression of the antagonist arch. Face bow transfer (Whip Mix Face bow0 will be done. Following the stone master model (Type IV dental rock, Fuji) obtention, the maxillary models will be mounted to a semi-adjustable articulator based on the face bow record and mandibular models will be then mounted with the aid of laterotrusive and MI records. The MI and laterotrusive records will be taken with a PVS bite registration material. The Cr-Ni frameworks will be fabricated with lost-wax technique (Brand?), manually layered with feldspathic veneering porcelain (Vita), and glazed by one experienced dental technician.
The test group FDPs (high translucent monolithic Zr) (Aidite Multilayer 3D) will be fabricated by a complete/model-free digital workflow. The digital quadrant impressions of the preparation, antagonist as well as bite registration will be obtained by the use of an IOS (Trios 3, 3Shape). The files will be sent to a CAD software (Dental System, 3Shape) directly via the communication tool (3 Shape Communicate, 3Shape). Following CAD, the high translucent monolithic Zr 3-unit FDPs will be computer-aided manufactured (CORITEC 350i Loader, imes-icore GmbH). FDPs will be high-gloss polished, glazed, and sent to the dental clinic for the try-in session. Monolithic Zr design and manufacturing process will be completed by one dental technician that is highly experienced in CAD/CAM.
Clinical occlusal adjustment:
A standardized occlusal adjustment strategy will be adopted and executed by one investigator for both control and test group FDPs. In half of the restoration sites, monolithic Zr restorations will be the ones to have been tried first whereas in the other half metal-ceramic FDPs were the first. Initially, distal and mesial approximal contact areas, then the internal fit will be checked and adjusted to eliminate any interferences in order to ensure the optimal fitting of the restorations. For the occlusal adjustment amount calculation, the FDPs will be fixed on the prepared teeth provisionally and scanned by an IOS (Trios 3, 3Shape) to record the pre-adjustment FDP volume. The occlusal contacts and adjustment needs were assessed while still the restorations are fixed. The occlusal adjustment strategy will be as follows: Under normal occlusal forces, 40-micron articulation paper (Arti-Check micro-thin, Bausch, Cologne, Germany) will be used and followed by 12-micron articulation foil (Shimstock-foil, Bausch, Cologne, Germany) under strong occlusal force. The FDPs' occlusal contact design will be ensured to hold the articulation foil under strong occlusal force. Thereafter, once ensuring the FDPs to remain fixed, intraoral digital quadrant impressions (Trios 3, 3 Shape) will be taken by the same investigator in order to record the post-adjustment volume of the FDPs. After chairside finishing and polishing of the adjustment areas, Monolithiz Zr FDPs will be adhesively luted by a composite cement as the definitive restoration.
研究设计
- 研究类型
- Interventional
- 分配方式
- Non Randomized
- 干预模型
- Parallel
- 主要目的
- Treatment
- 盲法
- Double (Participant, Outcomes Assessor)
入排标准
- 年龄范围
- 20 Years 至 75 Years(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 是
入选标准
- 未提供
排除标准
- •Patients and teeth that are not fulfilling the inclusion criteria
结局指标
主要结局
The evaluation of effectiveness of workflows by assesing the occlusal registration accuracy of 3-unit FDPs that were fabricated with two different work-flows
时间窗: At the baseline, the same day of delivery
The occlusal registration accuracy and effectiveness of both analog and digital workflows by means of comparing quantitatively the occlusal adjustment requirement of 3-unit tooth supported metal-ceramic and Zr FDPs produced by analog work-flow use of semi-adjustable articulators with face-bow transfer and complete digital workflow, respectively
次要结局
- Operator and Patient reported outcomes(Impression visit and baseline visit (restoration delivery))
研究者
Duygu Karasan
Research Asistant, DDS, PhD
Hacettepe University