跳至主要内容
临床试验/NCT04855084
NCT04855084已完成不适用

Occlusal Relationship Assesment of Monolithic Zirconia Fixed Dental Prosthesis

Duygu Karasan1 个研究点 分布在 1 个国家目标入组 14 人开始时间: 2018年5月24日最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
14
试验地点
1
主要终点
The evaluation of effectiveness of workflows by assesing the occlusal registration accuracy of 3-unit FDPs that were fabricated with two different work-flows

研究概览

简要总结

To analyze in vivo occlusal accuracy and occlusal adjustment requirement, a cross-over clinical trial was designed. Two 3-unit tooth-supported posterior FDPs were planned to be made for each patient's single missing tooth gap, one with complete analog workflow (control group) and the other complete digital workflow (test group). The analog workflow aims for a porcelain fused to metal (PFM) FDP whereas the digital workflow aims for 3-unit monolithic Zr FDP. PFor half of the restorations, digital impression was planned to be taken first and to be followed by analog impression. As for the occlusal adjustment, in half of the study sites monolithic Zr FDPs were planned to be tried-in first, followed by metal-ceramic FDP and vice versa.

One investigator (DK) was assigned to prepare the restoration sites and deliver the FDPs. All monolithic Zr and all metal-ceramic FDPs were designed and fabricated by the same experienced dental technician. One investigator (HL), that was not involved in the treatment intervention was assigned to make the 3D analysis of the volumetric occlusal adjustment amount.

详细描述

All teeth preparations will be carried out ensuring the minimum material thickness for monolithic FDPs (0.8-1 mm margin thickness, 1 mm occlusal thickness) by one experienced investigator (DK). To prevent any possible carry-over effect, the impression acquisition order will be randomized.

The control group FDPs (metal-ceramic) will be fabricated with a complete analog workflow. Accordingly, a polyether dual-phase impression (Impregum Penta Soft Quick and Soft Quick, 3M) will be taken from the restoration arch and a Polyvinylsiloxane (PVS) impression material will be used for the impression of the antagonist arch. Face bow transfer (Whip Mix Face bow0 will be done. Following the stone master model (Type IV dental rock, Fuji) obtention, the maxillary models will be mounted to a semi-adjustable articulator based on the face bow record and mandibular models will be then mounted with the aid of laterotrusive and MI records. The MI and laterotrusive records will be taken with a PVS bite registration material. The Cr-Ni frameworks will be fabricated with lost-wax technique (Brand?), manually layered with feldspathic veneering porcelain (Vita), and glazed by one experienced dental technician.

The test group FDPs (high translucent monolithic Zr) (Aidite Multilayer 3D) will be fabricated by a complete/model-free digital workflow. The digital quadrant impressions of the preparation, antagonist as well as bite registration will be obtained by the use of an IOS (Trios 3, 3Shape). The files will be sent to a CAD software (Dental System, 3Shape) directly via the communication tool (3 Shape Communicate, 3Shape). Following CAD, the high translucent monolithic Zr 3-unit FDPs will be computer-aided manufactured (CORITEC 350i Loader, imes-icore GmbH). FDPs will be high-gloss polished, glazed, and sent to the dental clinic for the try-in session. Monolithic Zr design and manufacturing process will be completed by one dental technician that is highly experienced in CAD/CAM.

Clinical occlusal adjustment:

A standardized occlusal adjustment strategy will be adopted and executed by one investigator for both control and test group FDPs. In half of the restoration sites, monolithic Zr restorations will be the ones to have been tried first whereas in the other half metal-ceramic FDPs were the first. Initially, distal and mesial approximal contact areas, then the internal fit will be checked and adjusted to eliminate any interferences in order to ensure the optimal fitting of the restorations. For the occlusal adjustment amount calculation, the FDPs will be fixed on the prepared teeth provisionally and scanned by an IOS (Trios 3, 3Shape) to record the pre-adjustment FDP volume. The occlusal contacts and adjustment needs were assessed while still the restorations are fixed. The occlusal adjustment strategy will be as follows: Under normal occlusal forces, 40-micron articulation paper (Arti-Check micro-thin, Bausch, Cologne, Germany) will be used and followed by 12-micron articulation foil (Shimstock-foil, Bausch, Cologne, Germany) under strong occlusal force. The FDPs' occlusal contact design will be ensured to hold the articulation foil under strong occlusal force. Thereafter, once ensuring the FDPs to remain fixed, intraoral digital quadrant impressions (Trios 3, 3 Shape) will be taken by the same investigator in order to record the post-adjustment volume of the FDPs. After chairside finishing and polishing of the adjustment areas, Monolithiz Zr FDPs will be adhesively luted by a composite cement as the definitive restoration.

研究设计

研究类型
Interventional
分配方式
Non Randomized
干预模型
Parallel
主要目的
Treatment
盲法
Double (Participant, Outcomes Assessor)

入排标准

年龄范围
20 Years 至 75 Years(Adult, Older Adult)
性别
All
接受健康志愿者
是

入选标准

  • •for the participants:
  • •The individuals with the mandibular or maxillary single missing occlusal unit (2nd premolar, 1st molar) adjacent to a premolar and/or molar tooth
  • •Participants over 20 years old with no contradiction of dental treatment.
  • •Good oral hygiene habits, healthy periodontal status, no sign of bruxism (e.g. attrition score >2 according to Wigdorowicz-Makowerowa, and/or muscle pain), and no self-reported grinding and/or clenching.
  • •Inclusion criteria for the abutment teeth included:
  • •No visible periapical lesion
  • •Presence of minimum 1:1 crown/root ratio
  • •Class I mobility (Nyman & Lindhe 2003)
  • •No probing depth more than 4mm
  • •Presence of natural opposing teeth with no restorative treatment.
  • •Presence of a stable maximum intercuspation (MI) relationship

排除标准

  • •Patients and teeth that are not fulfilling the inclusion criteria

研究组 & 干预措施

Complete Digital Fixed Dental Prosthesis

Experimental

Following the Digital Impression using 3 Shape Trios Intraoral scanner, digital design, and manufacturing of the Monolithic Zirconia FDPs.

Monolithic FDPs: before adjustment

Using Intraoral Scanner, occlusal relationship assessment of the Monolithic FDPs before the occlusal adjustment.

Monolithic FDPs: after adjustment

Using Intraoral Scanner, occlusal relationship assessment of the Monolithic FDPs after the occlusal adjustment.

干预措施: Monolithic FDPs: before adjustment (Other)

Complete Digital Fixed Dental Prosthesis

Experimental

Following the Digital Impression using 3 Shape Trios Intraoral scanner, digital design, and manufacturing of the Monolithic Zirconia FDPs.

Monolithic FDPs: before adjustment

Using Intraoral Scanner, occlusal relationship assessment of the Monolithic FDPs before the occlusal adjustment.

Monolithic FDPs: after adjustment

Using Intraoral Scanner, occlusal relationship assessment of the Monolithic FDPs after the occlusal adjustment.

干预措施: Monolithic FDPs: after adjustment (Other)

Complete Digital Fixed Dental Prosthesis

Experimental

Following the Digital Impression using 3 Shape Trios Intraoral scanner, digital design, and manufacturing of the Monolithic Zirconia FDPs.

Monolithic FDPs: before adjustment

Using Intraoral Scanner, occlusal relationship assessment of the Monolithic FDPs before the occlusal adjustment.

Monolithic FDPs: after adjustment

Using Intraoral Scanner, occlusal relationship assessment of the Monolithic FDPs after the occlusal adjustment.

干预措施: Metal fused porcelain FDPs: before adjustment (Other)

Complete Digital Fixed Dental Prosthesis

Experimental

Following the Digital Impression using 3 Shape Trios Intraoral scanner, digital design, and manufacturing of the Monolithic Zirconia FDPs.

Monolithic FDPs: before adjustment

Using Intraoral Scanner, occlusal relationship assessment of the Monolithic FDPs before the occlusal adjustment.

Monolithic FDPs: after adjustment

Using Intraoral Scanner, occlusal relationship assessment of the Monolithic FDPs after the occlusal adjustment.

干预措施: Metal fused porcelain FDPs: after adjustment (Other)

Analog Fixed Dental Prosthesis

Active Comparator

Following the Conventional Impression, transfer to the articulator with Face bow. Manufacturing of the FDPs with lost wax technique and veneering.

Metal fused porcelain FDPs: before adjustment

Using Intraoral Scanner, occlusal relationship assessment of the metal fused to porcelain FDPs before the occlusal adjustment.

Metal fused porcelain FDPs: after adjustment

Using Intraoral Scanner, occlusal relationship assessment of the metal fused to porcelain FDPs after the occlusal adjustment.

干预措施: Monolithic FDPs: before adjustment (Other)

Analog Fixed Dental Prosthesis

Active Comparator

Following the Conventional Impression, transfer to the articulator with Face bow. Manufacturing of the FDPs with lost wax technique and veneering.

Metal fused porcelain FDPs: before adjustment

Using Intraoral Scanner, occlusal relationship assessment of the metal fused to porcelain FDPs before the occlusal adjustment.

Metal fused porcelain FDPs: after adjustment

Using Intraoral Scanner, occlusal relationship assessment of the metal fused to porcelain FDPs after the occlusal adjustment.

干预措施: Monolithic FDPs: after adjustment (Other)

Analog Fixed Dental Prosthesis

Active Comparator

Following the Conventional Impression, transfer to the articulator with Face bow. Manufacturing of the FDPs with lost wax technique and veneering.

Metal fused porcelain FDPs: before adjustment

Using Intraoral Scanner, occlusal relationship assessment of the metal fused to porcelain FDPs before the occlusal adjustment.

Metal fused porcelain FDPs: after adjustment

Using Intraoral Scanner, occlusal relationship assessment of the metal fused to porcelain FDPs after the occlusal adjustment.

干预措施: Metal fused porcelain FDPs: before adjustment (Other)

Analog Fixed Dental Prosthesis

Active Comparator

Following the Conventional Impression, transfer to the articulator with Face bow. Manufacturing of the FDPs with lost wax technique and veneering.

Metal fused porcelain FDPs: before adjustment

Using Intraoral Scanner, occlusal relationship assessment of the metal fused to porcelain FDPs before the occlusal adjustment.

Metal fused porcelain FDPs: after adjustment

Using Intraoral Scanner, occlusal relationship assessment of the metal fused to porcelain FDPs after the occlusal adjustment.

干预措施: Metal fused porcelain FDPs: after adjustment (Other)

结局指标

主要结局

The evaluation of effectiveness of workflows by assesing the occlusal registration accuracy of 3-unit FDPs that were fabricated with two different work-flows

时间窗: At the baseline, the same day of delivery

The occlusal registration accuracy and effectiveness of both analog and digital workflows by means of comparing quantitatively the occlusal adjustment requirement of 3-unit tooth supported metal-ceramic and Zr FDPs produced by analog work-flow use of semi-adjustable articulators with face-bow transfer and complete digital workflow, respectively

次要结局

  • Operator and Patient reported outcomes(Impression visit and baseline visit (restoration delivery))

研究者

发起方
Duygu Karasan
申办方类型
Other
责任方
Sponsor Investigator
主要研究者

Duygu Karasan

Research Asistant, DDS, PhD

Hacettepe University

研究点 (1)

Loading locations...

相似试验