跳至主要内容
临床试验/NCT04381234
NCT04381234已完成2 期

Strategies for Asymmetrical Triacetate Dialyzer

Universitaire Ziekenhuizen KU Leuven2 个研究点 分布在 1 个国家目标入组 20 人开始时间: 2018年1月6日最近更新:
适应症

试验速览

阶段
2 期
状态
已完成
入组人数
20
试验地点
2
主要终点
clinical patency of the hemodialysis extracorporeal circuit

研究概览

简要总结

Not all dialysis patients tolerate heparin anticoagulation. Heparin should be avoided in patients at high risk of bleeding. Strategies include saline infusion, citrate-containing dialysate, regional citrate anticoagulation and heparin-coated membranes. We recently studied the combination of a heparin-coated membrane and citrate-containing dialysate, with a success rate of 94% . Although this combination resulted in low rates of clotting, heparin-coated membranes are not ubiquitously available. The quest for easy to perform, safe and affordable heparin-free dialysis is on. Asymmetric cellulose triacetate (ATA) dialyzers have a low degree of platelet contact activation and might be an alternative to heparin-coated dialyzers.

This is a phase II pilot study in maintenance dialysis patients. Study design is a two-arm open-label cross-over study. In Arm 1, patients were dialyzed using a 1.9 m2 ATA membrane (Solacea™-19H, Nipro Corp., Japan) in combination with citrate (1 mM) containing dialysate. In Arm 2, patients were dialyzed with the same 1.9 m2 ATA membrane, in combination with high volume predilution hemodiafiltration. The primary endpoint was the success rate to complete 4 hours of hemodialysis without preterm clotting.

详细描述

Anticoagulation is one of the supporting pillars of chronic hemodialysis (HD). The optimal anticoagulant regimen provides full anticoagulation of the extracorporeal circuit with minimal systemic effects and comes at an affordable cost. Unfractionated heparin (UFH) has been the standard of care for many years. In several countries, UFH has gradually been replaced by low molecular weight heparins (LMWH). LMWH are easy to use as they can be administered as a bolus injection and reduce membrane fibrin and platelet deposition. Both UFH and LMWH provide adequate anticoagulation of the extracorporeal circuit, at the price of systemic anticoagulation. Apart from bleeding, the administration of unfractionated heparins has also been associated with dyslipidemia, hypoaldosteronism and hyperkalemia, thrombopenia, osteoporosis, pruritus, and hypersensitivity reactions.

Several alternative anticoagulation regimens have been proposed including saline infusion, heparin coating of the dialyzer membrane as well as regional citrate anticoagulation. Regional citrate anticoagulation is performed by infusing citrate into the arterial line of the dialysis tubing to reduce ionized calcium concentrations in order to minimize propagation of the coagulation cascade. Ionized calcium concentrations are restored by calcium supplementation prior to reinfusion of the blood into the patient. The HepZero study suggested that regional citrate anticoagulation is superior to heparin-coated polyacrylonitrile dialyzers (AN69ST; Nephral 300ST, Gambro) and resulted in in significantly greater instantaneous urea nitrogen clearance. While generally safe and adequate, regional citrate anticoagulation requires additional actions during preparatory phase (preparation of citrate and calcium infusion pumps) as well as during the treatment (measurement of ionized calcium).

Recently, acetate-free citrate-containing dialysate concentrates were introduced into clinical practice. Besides the advantages of acetate-free dialysate, this provides a modest local anticoagulant effect inside the dialyzer. Citrate-containing dialysate allowed to reduce heparin dose while maintaining extracorporeal circuit patency and dialyzer clearance. Recently, citrate-containing dialysate and a heparin-coated dialyzer were combined. In one study, non-inferiority to regional citrate anticoagulation was demonstrated

The abovementioned studies demonstrate that hemodialysis without systemic heparinization is feasible. However, such procedures are more cumbersome, require more manpower, additional biochemical testing and/ or more expensive consumables. The aim of the current study is to test two different strategies for systemic heparin-free dialysis with an asymmetrical tri-acetate hemodialyzer.

Trial objectives To evaluate the feasability, safety and adequacy of systemic heparin-free dialysis using an asymmetrical tri-acetate dialyzer membrane, with or without the combination with citrate containing dialysate.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Crossover
主要目的
Treatment
盲法
None

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Patients age 18 years, or over. No maximum age is defined.
  • Providing signed and dated informed consent (ICF)
  • Maintenance dialysis (> 3 months of hemodialysis)
  • 'Standard' dialysis regimen (three dialysis sessions / week, dialysis duration 4 hours)
  • Hemodynamic stability during 4 weeks preceding study period. Hemodynamic instability is defined as any episode of low blood pressure (asymptomatic or symptomatic requiring intervention (bolus fluid infusion, temporarily withholding or reducing ultrafiltration, preterm termination of dialysis session, resuscitation)
  • Hemoglobin 9 - 12 g/dl.

排除标准

  • Any known medical disorder favoring either bleeding or clotting (e.g. atypical hemolytic uremic syndrome (aHUS), antiphospholipid syndrome, idiopathic thrombocytopenic purpura (ITP), paroxysmal nocturnal hemoglobinuria (PNH))
  • Treatment with a vitamin K antagonist
  • Treatment with any one of the NOACs (apixaban, rivaroxaban, edoxaban, dabigatran)
  • High risk of bleeding according to the criteria of Swartz (12).
  • Patients with a known allergic reaction to asymmetric triacetate
  • Pregnancy

结局指标

主要结局

clinical patency of the hemodialysis extracorporeal circuit

时间窗: 4 hours

clotting of the extracorporeal circuit

次要结局

  • Clotting of dialyser(4 hours)
  • dialysis adequacy(4hours)
  • Reduction ratio uremic retention solutes(4 hours)

研究者

申办方类型
Other
责任方
Sponsor

研究点 (2)

Loading locations...