Objective Assessment of Orbital Implant and Ocular Prosthesis Motility Using a Digital Imaging
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 入组人数
- 57
- 试验地点
- 2
- 主要终点
- Measurements of orbital implant and ocular prosthesis motility via the mediGrid app
研究概览
简要总结
This study will evaluate the degree of translational movement loss from orbital implant to ocular prosthesis. This will be measured using two software applications - Image J as well as the mediGrid smartphone app in measuring prosthesis motility by comparing it to the ruler as a "gold" standard.
详细描述
The fit and function of an ocular prosthetic determines the effective motility (movement) within the patient's eye socket. A poor fitting ocular prosthesis will lead to poor motility, patient discomfort and increased mucus discharge, and can risk the integrity of the anterior surface of the implanted orbit. Currently the method to determine best fit of the ocular prosthesis is dependent upon the ocularist's skill in adding or subtracting material from the wax model that is replicated from an initial alginate impression of the patient's eye socket.
The proposal of this study is to utilise digital imaging to capture images to measure the motility of both the orbital implant and the ocular prosthesis. Two methods will be compared: excursion measurements on a photograph using digital software (Image J) versus use of a smart phone app (an iOS app known as mediGrid (IRISS Medical Technologies, UK; CE Marked, HIPAA compliant). This study will evaluate the degree of translational movement loss from orbital implant to ocular prosthesis and analysis will include comparisons between hydroxyapatite and acrylic implants and in patients without an orbital implant, also known as post-enucleation socket syndrome (PESS). A part of this study will also evaluate the accuracy of the two softwares Image J as well as the mediGrid smartphone app in measuring prosthesis motility by comparing it to the ruler as a "gold" standard.
研究设计
- 研究类型
- Interventional
- 分配方式
- Na
- 干预模型
- Single Group
- 主要目的
- Other
- 盲法
- None
盲法说明
Non-masked study.
入排标准
- 年龄范围
- 18 Years 至 —(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •Adults with surgery to remove one eye
- •Able to give consent and understand the study
- •Able to cooperate by following instructions (keeping head still, perform gaze movements)
- •Enucleation was performed with the integrated implant technique (recti muscles sutured directly to the scleral cap or the mesh around the implant in a location corresponding to muscle insertion.
排除标准
- •Radiotherapy to socket
- •Chemotherapy
- •Implant exposure repair
- •Secondary orbital implant
- •Concurrent socket pathology:
- •Socket infection
- •Socket exposure
- •Giant papillary conjunctivitis
- •Presence of ocular motility disorders on either side of the face, such as nystagmus, known muscle restrictive disorders (thyroid eye disease, previous trauma, idiopathic orbital inflammatory disease) and neurological disorders (cranial neuropathies, multiple sclerosis).
结局指标
主要结局
Measurements of orbital implant and ocular prosthesis motility via the mediGrid app
时间窗: 1 Month
Orbital implant motility in patient with enucleated sockets will be measured with a mediGrid app. The app will evaluate the degree of translational movement loss from orbital implant to ocular prosthesis.