Comparison of Hemodynamic Changes of Tracheal Intubation With McCoy and Macintosh Laryngoscopes
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 发起方
- 入组人数
- 272
- 试验地点
- 2
- 主要终点
- Effect on the pulse of intubation with Macintosh and McCoy laryngoscope
研究概览
简要总结
A total of 272 patients were randomly allocated into two groups, Patients in group A were treated with Macintosh laryngoscope and in groups B with McCoy laryngoscope was used for endotracheal intubation. Pulse and systolic blood pressure was recorded by non-invasive measures before laryngoscopy and at 30 seconds, 2 and 3minutes after intubation. All this information was recorded on a Pro forma.
详细描述
After taking approval from hospital ethical committee, 272 patients who reported to Operation Theatre of CMH, Jhelum were selected for the study. Informed consent was obtained and patient demographic information (name, age, contact) was recorded. Patients were randomly divided in two equal groups by using lottery method. GROUP A: Where Macintosh laryngoscope was used for endotracheal intubation. GROUP B: Where McCoy laryngoscope was used for endotracheal intubation.
Before reporting to Operation theatre a detailed pre anesthesia assessment was done in all patients, all necessary laboratory investigations were collected. On OT table pulse and systolic blood pressure was checked by non-invasive method. 18G cannula was passed and ECG was attached. A pillow was placed under the head to obtain classical sniffing position for intubation. All the patients were pre medicated with injection midazolam 0.08mg/kg, injection nalbuphine 0.1 mg/kg, injection dexamethasone 0.08mg/kg and injection metoclopramide 0.1 mg/kg. Pre oxygenation was done with 100% oxygen for 3 mins. Induction was done with injection propofol2 mg/kg, muscle relaxation achieved with injection atracurium 0.5mg/kg. Laryngoscopy was started after 3 minutes by a qualified anesthetist. Pulse and systolic blood pressure was recorded by non-invasive measures before laryngoscopy and at 30 seconds, 2 and 3minutes after intubation. All this information was recorded on a Proforma.
研究设计
- 研究类型
- Interventional
- 分配方式
- Randomized
- 干预模型
- Parallel
- 主要目的
- Other
- 盲法
- None
入排标准
- 年龄范围
- 18 Years 至 70 Years(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •Both Male and Female
- •Age between 18 to 70
- •ASA I and II males and females.
- •Malampatti I and II.
- •Hemodynamically stable, no known ischemic heart disease and no history of hypertension.
- •Nil per oral for at least 6 hours.
排除标准
- •Non consenting patient.
- •ASA III, IV or V patient.
- •Malampati III or IV.
- •Cervical instability
- •Thyromental distance of less than 6cm, inter incisor distance of less than 3cm.
- •Known case of hypertension and ischemic heart disease.
- •Pregnant female.
- •Body mass index of more than
- •Patients of oropharyngeal surgery.
- •Unable to Intubate in less than 1 minute.
结局指标
主要结局
Effect on the pulse of intubation with Macintosh and McCoy laryngoscope
时间窗: After Laryngoscopy, pulse was recorded by non-invasive measures before laryngoscopy and at 30 seconds, 2 and 3 minutes after intubation.
To measure hemodynamic changes (i.e. pulse) of intubation with Macintosh and McCoy laryngoscope
Effect on the systolic blood pressure of intubation with Macintosh and McCoy laryngoscope
时间窗: After Laryngoscopy, systolic blood pressure was recorded by non-invasive measures before laryngoscopy and at 30 seconds, 2 and 3 minutes after intubation
To measure hemodynamic changes (i.e. systolic blood pressure) of intubation with Macintosh and McCoy
次要结局
未报告次要终点
研究者
M. Awais Qarni
Anesthesiologist
CMH Jhelum