Skip to main content
Clinical Trials/NCT07006038
NCT07006038CompletedNot Applicable

Vein Imaging Device on First-Attempt Success and Catheter Complications in Peripheral Intravenous Catheter Insertion

Dokuz Eylul University1 site in 1 country206 target enrollmentStarted: May 30, 2023Last updated:
Conditions
Interventions

Trial Snapshot

Phase
Not Applicable
Status
Completed
Enrollment
206
Locations
1
Primary Endpoint
PIC insertion success

Study Overview

Brief Summary

This study aimed to evaluate the impact of vein visualization device on catheter placement success and catheter-related complications during peripheral IV catheter insertion in pediatric emergency departments. This randomized controlled trial compares the group using a vein visualization device with the group using the standard method.

Detailed Description

There were two groups in this study: the vein imaging device and the control group.

The children to be included in this study consisted of pediatric patients who were admitted to the PED. There were two groups in this study: the vein imaging device and the control group. If the physician requested a peripheral intravenous catheter (PIC), the vein imaging device was applied to increase the first-attempt success of the PIC in one group. In addition, there was a control group in which any device was not used. One trained nurse who was a PhD student enrolled the participants who met the eligibility criteria.

The patients who were scheduled for PIC insertion were allocated to groups according to the randomization scheme. After providing information to the child and the parent, the investigator obtained consent from the parent, and the group assignment was determined. The patients in the control group did not receive any additional interventions and were observed during the PIC insertion after obtaining consent.

The PIC procedure time started when the tourniquet connected. In the vein imaging device and the control groups, communication with the child was maintained using the questions mentioned above during the procedure by the researcher nurse. When the phlebotomist nurse decided on the insertion site for the PIC, the PIC was attempted. If the PIC was inserted on the first attempt, the PIC procedure time stopped. If not, when the PIC was successfully inserted, the PIC procedure time was stopped. The PIC insertion time was recorded in minutes for successful PIC insertion. After the PIC insertion area was closed with dressing and the materials were collected, the child's pain was assessed by the PED nurse with the FLACC pain scale.

Complication signs and symptoms are monitored in the PIC area. If the PIC is to be removed for any reason, the reason and time of removal are recorded. PIC indwelling time was recorded. If it was removed due to a complication, the PIC area was followed up by grading with infiltration, extravasation, and phlebitis scales.

Study Design

Study Type
Interventional
Allocation
Randomized
Intervention Model
Parallel
Primary Purpose
Prevention
Masking
Single (Outcomes Assessor)

Masking Description

The child's pain was assessed by the other non-researcher PED nurse with the FLACC pain scale.

Eligibility Criteria

Ages
1 Month to 6 Years (Child)
Sex
All
Accepts Healthy Volunteers
No

Inclusion Criteria

  • •The physician must inform them that PIC must be inserted to administer medication and fluids
  • •The parent must voluntarily agree to participate in the study, consent form must be obtained from the parent

Exclusion Criteria

  • •The child presenting to the pediatric emergency department must be in shock or severely dehydrated, requiring urgent intervention
  • •No need for PIC
  • •Presence of a central venous catheter (since there will be no need for PIC)
  • •Selection of the lower extremities for PIC placement (since they may experience more pain and complication)
  • •Use of sedatives or analgesics before the PIC procedure (at least 4 hours before)

Arms & Interventions

Vein imaging device group

Experimental

the PIC insertion area was visualized with the help of the device by the nurse. The vein imaging device was used before the catheter insertion attempted to view the patient's veins.

Intervention: Veinlite PEDI2 (Device)

Control group

No Intervention

no vein imaging device was used before cathater insertion

Outcomes

Primary Outcomes

PIC insertion success

Time Frame: through the PIC insertion

first-attempt PIC insertion success

procedural time

Time Frame: through the PIC insertion

procedural time for successful PIC insertion

Secondary Outcomes

  • PIC insertion related pain score(FLACC score evaluated 3 minutes after the PIC insertion)
  • PIC indwelling time(through the PIC stay (If the PIC is to be removed for any reason, the reason and time of removal are recorded, PIC indwelling time was recorded as hours))

Investigators

Sponsor Class
Other
Responsible Party
Principal Investigator
Principal Investigator

Gülçin Özalp Gerçeker

Professor, Pediatric Nursing Department

Dokuz Eylul University

Study Sites (1)

Loading locations...

Similar Trials