Use of Mellitor Sensor for Continuous Glucose Monitoring - An Ex-Vivo Study

Mellitor2 个研究点 分布在 1 个国家目标入组 20 人开始时间: 2009年10月1日最近更新:
适应症

试验速览

阶段
不适用
发起方
入组人数
20
试验地点
2
主要终点
Mellitor technology feasibility will be established by comparing Mellitor glucose measurements results to "gold standard, Yellow Springs" glucose analyzer, or a comparable. Interdevice variability should be within 10%.

研究概览

简要总结

Most patients with diabetes mellitus have to measure their blood glucose levels quite often, in order to maintain a proper glycemic control. Current methods of self-monitoring of blood glucose are invasive, painful, uncomfortable, and only allow occasional, from time-to-time, measurements. Real-time continuous monitoring would provide a helpful tool for improvement of glycemic control, thus decreasing the incidence of hypoglycemia and improving glucose control. The Mellitor sensor is a new concept of continue glucose monitoring device. The Mellitor device is an implantable continuous glucose monitoring sensor that is intended for detection episodes of hyperglycemia and hypoglycemia in diabetic patients, and facilitates both acute and long-term therapy adjustments. This study was design in order to evaluate glucose measurement capabilities by the Mellitor sensor that is being developed. Transudate liquid samples, withdrawn in a clinical procedure and normally immediately disposed, will be used for glucose measurement by the Mellitor sensor.

Study Design

This study is an ex-vivo comparative study. 20 patients will be recruited for the study, according to patients' inflow and meeting eligibility criteria.

Study Goal

Study objective is to evaluate the feasibility of the Mellitor Sensor technology for glucose level measurement.

Study Endpoint

Mellitor technology feasibility will be established by comparing Mellitor glucose measurements results, based on transudate/exudates liquid withdrawal for other medical reasons, to "gold standard, Yellow Springs" glucose analyzer, or a comparable, calibrated and approved device using the same transudate/exudates liquid. Interdevice variability should be within 10%.

研究设计

研究类型
Interventional
分配方式
Non Randomized
干预模型
Parallel
主要目的
Diagnostic
盲法
None

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Male/Female aged 18 and up.
  • Subject was scheduled for transudate/exudate liquid withdrawal.
  • Subject able to comprehend and give informed consent for participation in this study.
  • Signed Informed Consent Form

排除标准

  • Known cognitive or psychiatric disorder.
  • Subjects with HIV.
  • Subject refuses to sign inform consent form.

结局指标

主要结局

Mellitor technology feasibility will be established by comparing Mellitor glucose measurements results to "gold standard, Yellow Springs" glucose analyzer, or a comparable. Interdevice variability should be within 10%.