Light-induced Effects on Dental Implant Stability

Not Applicable
Completed
Conditions
Missing Teeth
Interventions
Procedure: photofunctionalization
Registration Number
NCT05467488
Lead Sponsor
Prof. Abdul Mueed Zaigham
Brief Summary

Until now, limited research has observed the stability of photo functionalized sandblasted acid-etched (SLA) titanium implants. The study includes a sample size of sixty otherwise healthy patients with implant replacement, comparing nonirradiated, irradiated UVA and UVC titanium implants. It was an interventional study with a sample size divided into three groups using simple randomization. Patients with nonirradiated dental implants make the control group A with UVA and UVC dental implants forming groups B and C, respectively. Before functional loading, implant stability was measured on days zero and eight weeks. SPSS 26.0 is used for data analysis. The data for implant stability quotient (ISQ) levels and osseointegration speed index (OSI) were presented as mean ± SD for each group. The effect of UVA and UVC on ISQ2 compared with the baseline ISQ was done by applying multiple simple regression analysis models, whereas the distinction between UVA and UVC was made through a t-test. p ≤ 0.05 was kept statistically significant. The implants irradiated with UVA significantly affected ISQ levels compared to other groups.

Detailed Description

Not available

Recruitment & Eligibility

Status
COMPLETED
Sex
All
Target Recruitment
66
Inclusion Criteria
  • systemically healthy patients with age > 20 with at least one tooth or more missing
Exclusion Criteria

Study & Design

Study Type
INTERVENTIONAL
Study Design
PARALLEL
Arm && Interventions
GroupInterventionDescription
UVC irradiated group (group C)photofunctionalization-
UVA irradiated group (group B)photofunctionalization-
Primary Outcome Measures
NameTimeMethod
ISQ measurement through Ostelltm Mentor deviceeight months

The Ostelltm device was initially calibrated using a test peg called the ISQ. A smart peg was used for assessment. The smart peg tightened with 5 Ncm torque is then mounted on implant fixture and the transducer connected perpendicular to the implant . The measuring probe is brought closer to the smart peg without touching it. A beeping sound displays the reading on the monitor. Two successive readings are taken mesiodistally along the jaw and buccolingually perpendicular to the jaw .The RFA measurements taken twice during implant treatment are recorded. All the ISQ values were recorded from one to hundred and a mean was taken.

Secondary Outcome Measures
NameTimeMethod

Trial Locations

Locations (1)

Institute of Dentistry; CMH Lahore Medical College

🇵🇰

Lahore, Punjab, Pakistan