Factors Influencing Inadequacy in Rapid Onsite Evaluation of Ultrasound Guided Fine Needle Aspiration (FNA) Samples of Thyroid Nodules
试验速览
- 阶段
- 不适用
- 状态
- 招募中
- 入组人数
- 160
- 试验地点
- 1
- 主要终点
- rate of sample adequacy
研究概览
简要总结
Thyroid nodules are a common clinical finding with a prevalence of around 50-67% in the general population using ultrasound examinations. Of these, malignancies account for 5-15% including the treatable papillary and follicular thyroid carcinomas and the rarer but more aggressive medullary and undifferentiated thyroid cancers.
Fine Needle Aspiration (FNA) is a relatively simple, cost-effective recommended standard diagnostic procedure with high sensitivity and specificity for the preoperative evaluation of benign and malignant thyroid nodules.
Cytopathology reports of thyroid FNA are categorized using a universal grading system, which helps to standardize reporting of diagnostic thyroid cytology results. In the non-diagnostic/unsatisfactory category (Bethesda I), ranging from 1% to 20% of samples, pathologists are unable to make a clinical diagnosis based on these samples due to an inadequate number of cells or difficulty in identifying cells. The estimated risk of malignancy in this category is 1-4 %, which usually managed by repeating FNA with increase in patient discomfort, procedural complications and medical costs.
There are few other prospective studies investigated the effect of needle size, and sampling technique on sample adequacy.
详细描述
Thyroid nodules are a common clinical finding with a prevalence of around 50-67% in the general population using ultrasound examinations. Of these, malignancies account for 5-15% including the treatable papillary and follicular thyroid carcinomas and the rarer but more aggressive medullary and undifferentiated thyroid cancers.
The American Thyroid Association has devised an algorithm "Thyroid Imaging Reporting and Data System (TI-RADS) for evaluation and management of thyroid nodules based on US pattern and size to recommend fine needle aspiration (FNA) cytology to minimize unnecessary FNAs/thyroid surgeries for nodules that are most likely benign and to avoid over-treating micropapillary thyroid carcinoma which is indolent. Fine Needle Aspiration (FNA) is a relatively simple, cost-effective recommended standard diagnostic procedure with high sensitivity and specificity for the preoperative evaluation of benign and malignant thyroid nodules.
Cytopathology reports of thyroid FNA are categorized using a universal grading system called The Bethesda System for Reporting Thyroid Cytopathology, which helps to standardize reporting of diagnostic thyroid cytology results [3]. In the non-diagnostic/unsatisfactory category (Bethesda I), ranging from 1% to 20% of samples, pathologists are unable to make a clinical diagnosis based on these samples due to an inadequate number of cells or difficulty in identifying cells. The estimated risk of malignancy in this category is 1-4 %, which usually managed by repeating FNA with increase in patient discomfort, procedural complications and medical costs.
Several retrospective and prospective studies investigated the factors associated with non-diagnostic samples rates, most of which focused on ultrasound guidance, the rapid on-site cytological evaluation and cystic components of the nodule. However, there are few other prospective studies investigated the other nodule characteristics, needle size, and sampling technique.
研究设计
- 研究类型
- Interventional
- 分配方式
- Na
- 干预模型
- Single Group
- 主要目的
- Diagnostic
- 盲法
- None
入排标准
- 年龄范围
- 18 Years 至 —(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •Patients referred for FNA of thyroid nodules (TIRAD-3, 4 and 5 nodules).
排除标准
- •History of thyroid ablation before FNA
研究组 & 干预措施
thyroid FNA
All FNAs will be performed by experienced radiologists (of 5-year experience in thyroid FNA procedures). Patients will be positioned comfortably, typically in a supine position with neck extension after putting a pillow under shoulders to fully expose the patient's neck to allow optimal access to the nodule. Ultrasound guidance using Logic E9 machine (GE Healthcare, Chicago, IL, USA) or Sonoscape X5 Portable Ultrasound machine with high-frequency linear array probes (3-12 MHz) will be used to visualize the nodule accurately and guide needle placement. 5ml syringe with 21G needle, 3ml syringe with 23G needle or 22G Quincke tip spinal needle will be used for FNA. Needle insertion will be directed either trans-isthmic or lateral cervical approach. Aspirations will be conducted at different angles and within different nodule regions using a to-and-fro motion till getting blood stain in the needle hub to obtain representative samples. Maximum number of four passes will be performed .
干预措施: fine needle aspiration (Diagnostic Test)
结局指标
主要结局
rate of sample adequacy
时间窗: Day 1
Aspirated material will be expelled onto glass slides, which will be immediately fixed and stained for cytological analysis. Rapid On-Site Evaluation (ROSE) will be utilized to assess the sample adequacy during the procedure using the diff-quik (air-dried) slides, allowing for additional passes if necessary. In this situation, ROSE is not used for bedside diagnosis. An experienced pathologist reported the ical diagnosis/reporfinal cytologt only once the entire case (i.e. all of the slides) are reviewed according to the Bethesda criteria.: (I) nondiagnostic (ND) (fewer than six groups of well-visualized follicular cells, each group containing less than 10 well-preserved epithelial cells); (II) benign lesion; (III) atypia of undetermined significance/follicular lesion of undetermined significance (AUS/FLUS); (IV) follicular neoplasm/suspicious for follicular neoplasm (FN/SFN); (V) suspicious for malignancy; and (VI) malignancy.
次要结局
未报告次要终点
研究者
Ramy Mohammed Ahmed
lecturer and consultant of radiology