Roller Coaster Trial: Rotational Atherectomy, Lithotripsy or LasER for the Treatment of CAlcified
试验速览
- 阶段
- 不适用
- 入组人数
- 150
- 试验地点
- 1
- 主要终点
- Percentage of stent expansion by optical coherence tomography
研究概览
简要总结
Some data exist about the efficacy and safety of rotational atherectomy, intravascular lithotripsy and excimer laser to modify calcified plaques.
However there is no direct randomized comparison between these three tools in this scenario.
The aim of this pilot randomized trial is to compare the safety and efficacy of these three techniques during PCI of moderate to severe calcified lesions.
详细描述
Some data exist about the efficacy and safety of rotational atherectomy, intravascular lithotripsy and excimer laser to modify calcified plaques.
However there is no direct randomized comparison between these three tools in this scenario.
The aim of this pilot randomized trial is to compare the safety and efficacy of these three techniques during PCI of moderate to severe calcified lesions.
The primary endpoint will be the percentage of stent expansion measured with optical coherence tomography. Between secondary endpoints we will analyze the strategy success (defined as successful stent delivery and expansion with <20% residual stenosis and TIMI 3 flow without crossover or stent failure) and presentation of clinical adverse at 1 year follow-up .
研究设计
- 研究类型
- Interventional
- 分配方式
- Randomized
- 干预模型
- Parallel
- 主要目的
- Treatment
- 盲法
- None
入排标准
- 年龄范围
- 18 Years 至 —(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •Patients >18 years.
- •Stenosis ≥70% in a coronary artery with a diameter ≥2,5 y ≤4 mm.
- •Moderate to severe angiographic calcification
- •Stable coronary artery disease or NSTEMI.
- •Native coronary vessel or bypass graft.
排除标准
- •Knwon allergies to aspirin or P2y12 inhibitors.
- •Cardiogenic shock at the time of PCI.
- •Treated lesion in a bifurcation with side branch diameter > 2mm.
- •Absence of informed consent.
- •Impossibility for 1year follow up.
研究组 & 干预措施
Rotational Atherectomy
The procedure is performed by using a Rotablator system, which consists of a spring coil shaft with a burr at the tip. The front edge of the burr is the ablating portion, oval shaped, and covered with fine diamond crystals.
The rotational atherectomy catheter is introduced into the coronary artery over a dedicated long rotational atherectomy wire, which consists of a monofilament stainless steel 0.09-inch wire.
The device is connected to a console that houses the turbine that rotates the burr with pressurized nitrogen gas. Typically the rpm is set at 150,000 to 180,000 rpm.
After the lesion is crossed with the wire, the lesion is crossed with multiple "pecking" movements of the burr, with each run lasting not more than 20 seconds. After successful rotational atherectomy with one or more burrs, the procedure is completed with balloon angioplasty and stent placement. This can be achieved by exchanging the rota wire with a workhorse wire and using standard equipment.
干预措施: Percutaneous coronary Intervention (Device)
Intravascular Lithotripsy
The procedure is perforemed with a Coronary intravascular lithotripsy (IVL) System that consists of a generator, a connector cable with a push button to allow manually controlled delivery of electric pulses, and semi-compliant balloon catheter.
The balloon integrates two radiopaque lithotripsy emitters 6 mm that receive electrical pulses from the generator vaporising the fluid within the balloon and creating a rapidly expanding and collapsing bubble. This bubble can transmit unfocused circumferential pulsatile mechanical energy into the vessel wall, in the form of sonic pressure waves equivalent to approximately 50 atmospheres (atm). The IVL therapy consists on a maximun of 8 runs of 10 pulses (80 pulses). The number of therapies needed per lesion will depend on lesion resistance; however, a mínimum of 20 pulses is recommended.
Alter IVL, an optional additional post-dilatation with non-compliant balloons, a stent is implanted
干预措施: Percutaneous coronary Intervention (Device)
Excimer Laser
Excimer laser is pulsed gas laser that use Xenon chloride (XeCl) as the active medium to generate pulses of short wavelength, high-energy ultraviolet (UV) light.
Excimer laser tissue ablation is mediated through three distinct mechanisms: photochemical, photo-thermal and photomechanical. UV laser light is absorbed by intra-vascular material and breaks carbon-carbon bonds (photochemical). It elevates the temperature of intra-cellular water, causing cellular rupture and generates a vapor bubble at the catheter tip (photo-thermal). Expansion and implosion of these bubbles disrupts the obstructive intra-vascular material (photomechanical). The laser catheter is advanced slowly over a conventional wire while the therapy is aplied and saline is inffused. After laser, balloon dilatation is usually performed finishing the procedure with stent implantation
干预措施: Percutaneous coronary Intervention (Device)
结局指标
主要结局
Percentage of stent expansion by optical coherence tomography
时间窗: At the end of percutaneous coronary intervention
We will analyze with optical coherence tomography the percentage of stent expansion (defined as the minimal stent area divided by the mean of the proximal and distal reference lumen areas).
次要结局
- Strategy success rate(At the end of percutaneous coronary intervention)
研究者
Alfonso Jurado, MD, PhD
Principal Investigator
Hospital Universitario La Paz
