Improving the Endotracheal Tube Cuff Pressure Control Management Knowledge of Intensive Care Nurses: A Quasi-Experimental Study Pre-Post Test
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 入组人数
- 88
- 试验地点
- 2
- 主要终点
- The Knowledge Level Evaluation Form-Post-test
研究概览
简要总结
This study aimed to evaluate how an educational intervention based on the existing evidence-based guidelines, using both active and passive educational implementetion strategies, could improve the knowledge of nurses regarding managing ETT cuff pressure control.
Hypothesis H1: There is a difference between the training given with the active and passive implementation strategies method in improving the endotracheal cuff pressure control knowledge of intensive care nurses.
详细描述
This study was carried out as a quasi-experimental two-group pretest-posttest research design to evaluate the effect of endotracheal tube cuff pressure control training given with the active and passive implementation strategies methods on the knowledge level of nurses. The research was carried out in the intensive care units of a Training and Research Hospital, between June and December 2022, in 6 intensive care units (General ICU 1-General ICU 2- General ICU 3, CVC ICU, 2nd Level ICU, Coronary ICU).
In the intensive care unit of the hospital where the study was conducted, the endotracheal tube cuff pressure is controlled by the pilot balloon finger palpation method in four hours. In addition, pressure measurement was not made with the cuff manometer. However, in endotracheal tube cuff control, cuff pressure should be monitored to prevent aspiration and the cuff pressure should be kept between 20-30 cmH2O. Before the data of the study started to be collected, a cuff manometer was purchased by the hospital management to be used in the intensive care units.
The universe of the research consisted of 120 nurses working in the intensive care units where the study was conducted. The necessary sample of the study was determined by using G*Power computer software program version 3.0.1 as recommended to be used in calculating the desired sample by previous studies. The sample consisted of 90 nurses scheduled for, with a power value to represent 95% of the study population at a 80% confidence interval, 0.05 error level, and 0.6 effect size according to power analysis. Research Randomizer software (http://www.randomizer.org.) was used to generate a randomized list by applying a simple randomization technique to each participant's allocation. The 90 participants were divided into two even groups (Intervention Group =45, Control Group =43 nurses).
Sociodemographic and occupational characteristics form and knowledge level evaluation form regarding endotracheal tube cuff pressure control were used to collect the data of the study.
Since the nurses working in the intensive care unit work in day and night shifts, the sociodemographic and occupational characteristics form to be applied before the training and the knowledge level evaluation form on endotracheal tube cuff pressure control (pretest) were collected by the researchers after the nurses' shift delivery hours. After applying the pre-test questionnaires (experimental /Control group), on the days determined together with the intensive care unit nurses in charge and the nursing services directorate, all nurses were given theoretical training on endotracheal tube cuff pressure management through a 4-hour presentation prepared with evidence-based guide and literature. Thus, all nurses gained equal knowledge. A PowerPoint presentation including endotracheal tube cuff pressure normal values, complications related to endotracheal tube cuff pressure, management of endotracheal tube cuff pressure, endotracheal tube cuff pressure control methods, methods affecting endotracheal tube cuff pressure, how to measure endotracheal tube cuff pressure was made.
研究设计
- 研究类型
- Interventional
- 分配方式
- Randomized
- 干预模型
- Parallel
- 主要目的
- Other
- 盲法
- None
入排标准
- 年龄范围
- 18 Years 至 47 Years(Adult)
- 性别
- All
- 接受健康志愿者
- 是
入选标准
- •Working as a nurse in intensive care units
- •Nurses who participated in the theoretical training and visited for follow-up
- •Volunteer to participate in the study
排除标准
- •Not willing to participate in the study
- •Forms with missing answers were not included in the evaluation
结局指标
主要结局
The Knowledge Level Evaluation Form-Post-test
时间窗: 3 months after theoretical training
Knowledge level evaluation form on endotracheal tube cuff pressure control consists of 20 questions about the safe limits of endotracheal tube cuff pressure, complications of endotracheal tube cuff pressure that is not within safe limits, the factors affecting endotracheal cuff pressure, and the level of knowledge about endotracheal tube cuff pressure control methods and was prepared by researchers in line with the literature. While creating the survey, expert opinion was obtained. The 20-item knowledge level form was developed to assess the knowledge of nurses on ETT cuff pressure control by researchers. Only one item (part 1) had four answers options the range of ETT cuff pressure, "10-20cmH2O", "20-30 cmH2O", "30-40 cmH2O" and "above 40cmH2 O". Another items had two answers options, "correct" and "incorrect". While scoring, correct answers scored one point each, when incorrect answers options scored zero
The Knowledge Level Evaluation Form- Pre- test
时间窗: before theoretical training
Knowledge level evaluation form on endotracheal tube cuff pressure control consists of 20 questions about the safe limits of endotracheal tube cuff pressure, complications of endotracheal tube cuff pressure that is not within safe limits, the factors affecting endotracheal cuff pressure, and the level of knowledge about endotracheal tube cuff pressure control methods and was prepared by researchers in line with the literature. While creating the survey, expert opinion was obtained. The 20-item knowledge level form was developed to assess the knowledge of nurses on ETT cuff pressure control by researchers. Only one item (part 1) had four answers options the range of ETT cuff pressure, "10-20cmH2O", "20-30 cmH2O", "30-40 cmH2O" and "above 40cmH2 O". Another items had two answers options, "correct" and "incorrect". While scoring, correct answers scored one point each, when incorrect answers options scored zero
次要结局
未报告次要终点
研究者
Selda Karaveli Çakır
Assistant professor
Kastamonu University