Technology Assisted Rehabilitation for Upper Limb Function in Myotonic Dystrophy Type 1
- Conditions
- Myotonic Dystrophy Type 1 (DM1)
- Interventions
- Device: Tyromotion Amadeo and Armeo Senso
- Registration Number
- NCT05560438
- Lead Sponsor
- University of Oslo
- Brief Summary
Myotonic Dystrophy type 1 (DM1) is a genetic multisystem disease causing muscle weakness and myotonia. As a result, upper limb function might become impaired. There are little research regarding rehabilitation and exercise for upper limb function in DM1. It is known from research on lower limb function in DM1 and other muscular dystrophies, that there are possibilities to improve function also in these deteriorating diseases. In this single subject experimental design study, 6-10 adults with DM1, who are at an inpatient rehabilitation center, will get intensive, but personally adapted senso- and robot assisted rehabilitation for arm- and hand function with Tyromotion Amadeo and Armeo Senso. These devices have previously been used in rehabilitation research for other neurological conditions. The participants will be followed up, and evaluated at a weekly basis, using video consultations. Fine motor skill dexterity test (9HPT) and the Nut and Bolt test will be used, and active range of motion (ROM) and muscle strenght and movement of upper limb will be measured. Furthermore, patient reported outcome measures (PROMS) on hand impairment and myotonia will be used, all with purpose to evaluate upper limb function.
- Detailed Description
Not available
Recruitment & Eligibility
- Status
- COMPLETED
- Sex
- All
- Target Recruitment
- 6
- Granted rehabilitation at Vikersund Rehabilitation center Genetical confirmed myotonic dystrophy diagnosis MIRS score between 2-5
- MIRS score on 1 Reduced Cognitive function and unable to participate in technological rehabilitation and digital evaluation
Study & Design
- Study Type
- INTERVENTIONAL
- Study Design
- SINGLE_GROUP
- Arm && Interventions
Group Intervention Description Technorehab Tyromotion Amadeo and Armeo Senso Rehabilitation using Tyromotion Amadeo and Armeo Senso
- Primary Outcome Measures
Name Time Method Fine motor skill dexterity test, 9 hole peg test (9HPT) 1-3 minutes Motor skill test
- Secondary Outcome Measures
Name Time Method Nut and Bolt test 5 minutes Motor skill test
Pinch Gauge 5 minutes Finger strength measures by Jamar digital pinch gauge
Hand strength 5 minutes Measured by Jamar digital dynamometer
Range of motion (ROM) 5-10 minutes Measure of ROM in upper limb joints
Trial Locations
- Locations (1)
Vikersund Rehabilitation Center
🇳🇴Vikersund, Viken, Norway