Skip to main content
Clinical Trials/NCT05290675
NCT05290675CompletedNot Applicable

Impact of Sample Type and Assay Time on the Performance of the Quantra QPlus System

HemoSonics LLC1 site in 1 country50 target enrollmentStarted: November 4, 2021Last updated:
Conditions

Trial Snapshot

Phase
Not Applicable
Status
Completed
Enrollment
50
Locations
1
Primary Endpoint
Comparison of QPlus Platelet Contribution to Clot stiffness (PCS) in arterial and venous samples

Study Overview

Brief Summary

This is a single center prospective observational study to compare QPlus parameter measurements in arterial and venous blood samples collected in parallel from patients undergoing cardiac surgery.

Detailed Description

In this single center prospective observational study, 40 cardiac surgery subjects will enrolled, each with parallel artrial and venous samples collected at 3 time points to yield 120 matched samples for analysis on the Quantra System with the QPlus Cartridge.

Study Design

Study Type
Observational
Observational Model
Cohort
Time Perspective
Prospective

Eligibility Criteria

Ages
18 Years to — (Adult, Older Adult)
Sex
All
Accepts Healthy Volunteers
No

Inclusion Criteria

  • Subject is scheduled for cardiac surgery, utilizing cardiopulmonary bypass, or including placement of a ventricular assist device
  • Subject is ≥18 years
  • Subject or subject's legally authorized representative is willing to participate and he/she has signed a consent formr.

Exclusion Criteria

  • Subject is younger than 18 years
  • Subject is pregnant
  • Subject is incarcerated at the time of the study
  • Subject is affected by a condition that, in the opinion of the surgical team, may pose additional risks
  • Subject, or subject's legally aurthorized representative is able to provide written informed consent

Outcomes

Primary Outcomes

Comparison of QPlus Platelet Contribution to Clot stiffness (PCS) in arterial and venous samples

Time Frame: During cardiac surgery

Measure of the shear modulus or strength/quality of the clot contributed by platelets determined using SEER sonorheometry assessed in two sample types

Comparison of QPlus Clot time (CT) in arterial and venous samples

Time Frame: During cardiac surgery

Coagulation function assessed in two sample types

Comparison of Clot stiffness (CS) determined with Quantra QPlus Cartridge in arterial and venous samples

Time Frame: During cardiac surgery

Measure of the overall shear modulus or strength/quality of the clot determined using SEER sonorheometry assessed in two sample types

Comparison of QPlus Fibrinogen Contribution to Clot stiffness (FCS) in arterial and venous samples

Time Frame: During cardiac surgery

Measure of the shear modulus or strength/quality of the clot contributed by fibrinogen determined using SEER sonorheometry assessed in two sample types

Comparison of QPlus Clot time with Heparinase (CTH) in arterial and venous samples

Time Frame: During cardiac surgery

Coagulation function assessed in two sample types

Secondary Outcomes

No secondary outcomes reported