Evaluation of Three Hard Relining Materials in Complete Dentures

Not Applicable
Completed
Conditions
Complete Mandibular Dentures With Poor Retention
Interventions
Other: Rebase II Fast
Other: Flexacryl
Other: Vertex
Registration Number
NCT02203279
Lead Sponsor
Damascus University
Brief Summary

Purpose: The purpose of this study is to evaluate three hard relining materials after 3 and 6 months of use with mandibular complete dentures. The effect of hard relining materials on supporting tissues and patients' satisfaction will also be assessed.

Materials and Methods: 36 complete edentulous patients who already have maxillary dentures and complaining of instable mandibular dentures will be invited to participate in this study. Mandibular dentures will be relined randomly by one of three relining materials: two chairside relining materials (Tokuyama Rebase II Fast, Tokuyama Dental Co, Japan), and (Flexacryl Hard, Lang Co, USA) and one heat cured acrylic resin (Vertex, Dental technology Co, Holland).

The color stability of relining material, peeling, and the effect on supporting tissue will be assessed by two separate prosthodontists after 3 and 6 months of follow up. In addition, patients will be asked to grade there overall satisfaction on a Visual Analogue Scale (VAS) ranging from 0 to 100.

Detailed Description

Relining denture is a process of resurfacing the tissue side of a denture to make it fit more accurately Direct relining of removable dentures with hard chair-side reline materials is suitable for improving the fit of the denture bases to the supporting tissues. Chairside reline materials are more convenient than those processed in a laboratory because the direct method is faster and does not cause clinically significant dimensional changes of the reline resin. However, when autopolymerized reline resins are used with a direct method, several problems can occur as burning sensation caused by monomers, an exothermic heat reaction and an unpleasant odor.

There are three types of hard relining chair-side materials: Dual-polymerized Visible light-polymerized as Triad DuaLine, Light Liner (Hard), Astron LC (Hard).Visible light-polymerized as Lightdon-U, Triad Hi-Flow Reline Material, Triad VLC Reline Material. Finally, autopolymerized as New Truline, Tokuyama Rebase II (Fast) , GC Reline. Other concerns related to direct reline materials include patient tolerance (taste, temperature, odor), color stability, durability and ease of handling and polishing.

Few studies evaluated the effect of disinfection solutions on relining materials properties as roughness and hardness. In one study, disinfectant solutions caused a decrease in hardness, whereas with roughness, the materials tested showed a statistically significant increase, except for Tokuyama. Depending on the examined relining materials, some materials have increased and the others have decreased surface roughness after immersion in disinfecting solutions or microwave disinfection.

All previous laboratory studies concentrated on the effects of disinfection on relining materials properties as roughness, hardness, color change. However, the clinical studies did not compare chemically cured and heat cured relining materials and their effects on supporting tissue. The aim of this study is to evaluate the clinical performance of two -chemically cured- and heat cured denture relining material after 3 and 6 months of use. In addition, the effect of hard relining materials on supporting tissues, and patients' satisfaction has not been evaluated yet.

Recruitment & Eligibility

Status
COMPLETED
Sex
Male
Target Recruitment
36
Inclusion Criteria
  • Age between 45-80 year,
  • complete maxillary and lower dentures
  • Mandibular dentures with poor retention
Exclusion Criteria
  • Patients with good stability of mandibular dentures.
  • Partial maxillary edentulous patients

Study & Design

Study Type
INTERVENTIONAL
Study Design
PARALLEL
Arm && Interventions
GroupInterventionDescription
Rebase II FastRebase II FastThe direct chair-side relining materiel 'Rebase II Fast' will be used.
FlexacrylFlexacrylThe direct chair-side relining material Flexacryl will be used
VertexVertexVertex is a heat-cured resin material which is going to be used for indirect relining
Primary Outcome Measures
NameTimeMethod
Supporting Alveolar Mucosa Status_6This variable will be assessed at six months following relining

According to a clinical examination by two prosthodontists, the supporting alveolar mucosa will be given one of the following levels:

Class I: The presence of reddish soft tissues extending to more than half of the area of the supporting mucosa or the presence of large areas of movable tissues.

Class II: The presence of irritated soft tissues extending to about third of the area of the supporting mucose or the presence of some areas of movable tissues at the top of the alveolar ridge.

Class III: The soft tissues appear in general as normal and fixed except for small isolated areas.

Class IV: The soft tissues appear normal and fixed without any signs of irritation or denture-induced injuries.

Color Stability_3This will be assessed at three moths following relining

The color stability variable has four degrees on clinical examination:

1. no change

2. simple

3. medium

4. large

Supporting Alveolar Mucosa Status_3This will be measured at three months following relining

According to a clinical examination by two prosthodontists, the supporting alveolar mucosa will be given one of the following levels:

Class I: The presence of reddish soft tissues extending to more than half of the area of the supporting mucosa or the presence of large areas of movable tissues.

Class II: The presence of irritated soft tissues extending to about third of the area of the supporting mucose or the presence of some areas of movable tissues at the top of the alveolar ridge.

Class III: The soft tissues appear in general as normal and fixed except for small isolated areas.

Class IV: The soft tissues appear normal and fixed without any signs of irritation or denture-induced injuries.

Secondary Outcome Measures
NameTimeMethod
Satisfaction_3This is going to be measured at three months following relining

Patient's satisfaction: patients will be asked to grade there overall satisfaction on a visual analogue scale (VAS) ranging from 0 to 100.

Peeling_3This variable is going to be assessed at three months following relining

This variable is going to be inspected clinically and it has two categories:

1. peeling more than 4 mm

2. peeling less than 4 mm

Peeling_6This variable is going to be assessed at six months following relining

This variable is going to be inspected clinically and it has two categories:

1. peeling more than 4 mm

2. peeling less than 4 mm

Satisfaction_6This is going to be measured at six months following relining

Patient's satisfaction: patients will be asked to grade there overall satisfaction on a visual analogue scale (VAS) ranging from 0 to 100.

Color Stability_6This be assessed at six months following relining

The color stability variable has four degrees on clinical examination:

no change simple medium large

Trial Locations

Locations (1)

Department of Removable Prosthodontics, University of Damascus Dental School

🇸🇾

Damascus, Syrian Arab Republic