MedPath

Power Injectable Versus a Non-Power Injectable, Upper Arm, TIVAD for Chemotherapy

Not Applicable
Completed
Conditions
Malignancy
Interventions
Device: Non-Power Injectable Port (Cook Vital Mini Port)
Device: Power Injectable Port (AngioDynamics Smart Port CT Mini)
Registration Number
NCT02282449
Lead Sponsor
University of Saskatchewan
Brief Summary

Patients with cancer often require intravenous chemotherapy for long periods of time.

Ensuring that these patients have safe and reliable access to the veins for chemotherapy is challenging, and sometimes a medical device is required to administer the chemotherapy into the veins.

A totally implanted venous access device, or port, is implanted under the skin of the arm and is attached to a small plastic catheter that enters into the veins. This device can be punctured with a needle when needed for treatment or testing.

Some types of these vein ports can rapidly inject fluids (power injection), and can be used for follow-up imaging studies, such as computed tomography, that are required to follow cancer treatment effectiveness. There are no publications of randomized patients discussing the impact of power injection upon TIVAD complications and device longevity for arm implantation. The investigators propose to compare the effectiveness of power injectable against non-power injectable ports to determine if they have different clinical performance and complications. Our results will impact the care provided to cancer patients.

Detailed Description

Hypothesis:

The null hypothesis envisions both devices performing similarly in regards to chemotherapy and complications. However, the power injectable population will experience the high flow, large volume injections, may experience complications of injection extravasation and port damage due to the more vigorous injection parameters.

Trial Objectives:

1. To prospectively assess the functionality and complications of a power injectable vs. a non-power injectable TIVAD in a cohort of breast cancer patients requiring intravenous chemotherapy. The TIVAD will be randomly assigned to each patient.

2. Assess quality of life for subjects who have the two different TIVADs.

3. Facilitate device selection for future cancer patients requiring chemotherapy.

We will perform a randomized, prospective clinical trial of patients with cancer to compare a non-power injectable port, Cook Vital Mini Port (Cook Canada, Mississauga, ON), with a power injectable port, the AngioDynamics Smart Port CT Mini (AngioDynamics Inc., Manchester, GA, USA).

Adverse events, such as arm swelling, skin rash, and incision dehiscence, etc., will be tracked via an online reporting system, a patient registry, and by follow-up strategies related to imaging and clinical assessments at regular time intervals.

Patient Follow-up:

From the Insertion date, a 7 day post insertion telephone interview will be performed. Subsequently the following will be obtained at 3 months and 12 months post port insertion.

Clinical examination Venous Doppler US (arm/neck) Chest and arm X-ray QLQC30 questionnaire QLAVD-PA questionnaire Adverse Event Record

Details of Follow-up:

Clinical Examination:

Visual inspection of the arm, port implantation site, neck, and anterior chest.

1. Distended arm, neck or chest veins - Y/N - details

2. Swollen or edematous arm, neck, chest - Y/N - details

3. Skin rash - Y/N - details

4. Signs of arm infection - redness, swelling, purulent discharge - Y/N - details

5. Abnormal incision site of port insertion - Y/N - details

Venous Doppler Ultrasound (arm/neck):

Ultrasound will assess for vein thrombosis or narrowing.

Chest and arm x-rays:

Standard x-rays to include the arm from at least the elbow to axilla, full chest x-ray.

QLCC30 and QLAVD-PA:

Quality of Life surveys.

Adverse Events:

7 days, 3 months, 12 months, up to 24 months if possible - The patient will be contacted by telephone to determine if they have experienced any adverse events.

Recruitment & Eligibility

Status
COMPLETED
Sex
All
Target Recruitment
209
Inclusion Criteria
  • Consecutive patients breast cancer requiring intravenous chemotherapy, referred from our local Cancer Agency for arm TIVAD, will be included.
Exclusion Criteria
  • • Those under the age of 16 years;

    • Those with uncorrectable blood clotting disorder;
    • Pregnant women, as they will not be candidates for chemotherapy;
    • Any person with an active infection or immunocompromised state;
    • Those on oral or intravenous antibiotics on the day of TIVAD implantation.

Study & Design

Study Type
INTERVENTIONAL
Study Design
PARALLEL
Arm && Interventions
GroupInterventionDescription
Non-Power Injectable PortNon-Power Injectable Port (Cook Vital Mini Port)The subjects randomized to this group will receive the older, non-power injectable port.
Power Injectable PortPower Injectable Port (AngioDynamics Smart Port CT Mini)The subjects randomized to this group will receive the newer, power injectable port.
Primary Outcome Measures
NameTimeMethod
Device Failure (Failure secondary to occlusion, leakage, catheter fracture, wound dehiscence)2 years after insertion

Failure secondary to occlusion, leakage, catheter fracture, wound dehiscence

Secondary Outcome Measures
NameTimeMethod
Venous Thrombosis2 years after implantation

Ipsilateral US of veins of arm and neck to detect venous thrombosis

Quality of Life Related to Port2 years after implantation

Surveys of quality of life will be performed for each device

Infection2 years after implantation

Detect implantation site or systemic infection related to the port.

Trial Locations

Locations (1)

Medical Imaging, Royal University Hospital, 103 Hospital Drive

🇨🇦

Saskatoon, Saskatchewan, Canada

© Copyright 2025. All Rights Reserved by MedPath