跳至主要内容
临床试验/NCT01832818
NCT01832818终止不适用

A Prospective, Feasibility, Multi-Center Nonrandomized Clinical Trial Evaluating the Safety and Effectiveness of NuNec® Cervical Arthroplasty System

Pioneer Surgical Technology, Inc.1 个研究点 分布在 1 个国家目标入组 14 人开始时间: 2012年3月最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
终止
入组人数
14
试验地点
1
主要终点
Neck Disability Index (NDI) Score Improvement of at Least 15 Points

研究概览

简要总结

The objective of this study is to evaluate long-term safety and effectiveness of the NuNec® Cervical Arthroplasty System in a small patient population. The NuNec device is currently CE marked and commercially available in Europe.

详细描述

The NuNec® feasibility study is a prospective, multi-centered, non-randomized clinical trial. Only patients who have been diagnosed with single level, C3 to C7, symptomatic cervical degenerative disc disease and have failed at least 6 weeks of conservative treatment or present signs of progression of spinal cord/nerve root compression with continued non-operative care will be enrolled.

Patients will be evaluated preoperatively and postoperatively at discharge, 6 weeks, 3, 6, 12 and 24 months.

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Treatment
盲法
None

入排标准

年龄范围
21 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • is at least 21 years of age and skeletally mature
  • must have symptomatic degenerative disc disease at one level in the cervical spine, C3 to C7, demonstrated by herniated disc and/or spondylosis;
  • must have completed a minimum of six weeks of unsuccessful conservative, non-operative care or has the presence of progressive symptoms or signs of nerve root/spinal cord compression in the face of conservative treatment
  • must score at least 15/50 (30%) on the Neck Disability Index
  • is willing and able to follow the post-operative management program
  • must understand and sign the informed consent document

排除标准

  • symptomatic cervical DDD at more than one level
  • axial neck pain as the primary diagnosis without evidence of neural compression
  • neck or arm pain of unknown etiology
  • any significant anatomical consideration which would make the anterior cervical approach excessively risky or impossible
  • severe spondylosis at the target level
  • prior surgery at the target level
  • fused level adjacent to the target level
  • osteoporosis, osteopenia, osteomalacia, Paget's disease or metabolic bone disease
  • active infection or surgical site infection
  • is using any medication known to interfere with bone/soft tissue healing
  • diabetes mellitus requiring daily insulin management
  • any terminal, systemic, or autoimmune disease
  • medical conditions or mental incompetence which may interfere with study requirements
  • BMI >40 or a weight more than 100 lbs over ideal body weight
  • chemical dependency problem that may interfere with study requirements
  • current smokers
  • history of any invasive malignancy unless treated and in remission for at least two years
  • documented allergies to metal or plastic
  • currently pregnant, or interested in becoming pregnant during the study follow-up

研究组 & 干预措施

NuNec Cervical Disc

Experimental

Each patient will be implanted with the NuNec Cervical Disc in a single level from C3 to C7. Postoperatively, patient evaluated at discharge, 6 weeks, 3, 6, 12 and 24 months.

干预措施: NuNec Cervical Disc (Device)

结局指标

主要结局

Neck Disability Index (NDI) Score Improvement of at Least 15 Points

时间窗: At 24 months

The Neck Disability Index is a patient reported outcome measure for self-rated disability due to neck pain. Each of the 10 items is scored from 0 - 5. The maximum score is therefore 50. The obtained score can be multiplied by 2 to produce a percentage score. A higher score would indicate that the patient did not improve.

Visual Analog Scale (VAS) Improvement of 2.0 cm for Neck Pain

时间窗: At 24 months

The pain Visual Analog Scale is a uni-dimensional measure of pain intensity, represented by a 100 mm line, anchored by "no pain" (score of 0) and "pain as bad as it could be" or "worst imaginable pain" (score of 100 \[100-mm scale\]). A higher score would indicate that the patient had a worse outcome.

Serious Adverse Events Related to the Device

时间窗: Up to 24 months

The number of serious adverse events have been recorded

Device Failures or Removals, Revisions, Re-operations

时间窗: Up to 24 months

The failures or re-operations or supplemental fixation at the treated level

次要结局

  • Patient Satisfaction(At 24 months)
  • Absence of Device Migration or Subsidence(Up to 24 months)

研究者

申办方类型
Industry
责任方
Sponsor

研究点 (1)

Loading locations...