跳至主要内容
临床试验/NCT00675038
NCT00675038已完成不适用

Pilot Study of Non-Invasive Assessment of Hepatic And Myocardial Iron Through T2* MRI In Patients With Iron Overload

St. Jude Children's Research Hospital1 个研究点 分布在 1 个国家目标入组 52 人开始时间: 2005年10月最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
入组人数
52
试验地点
1

研究概览

简要总结

Many hematological disorders are treated by giving red blood cells. Over a long period of time iron from the red blood cell will accumulate in the tissues of the heart, liver, and endocrine glands. This condition is referred to as iron overload and may become life threatening due to the effects of the iron on these tissues. The normal method for evaluation of iron overload is a liver biopsy. This procedure is invasive and has potential risks, such as bleeding and infection.

It is very desirable to establish a method for assessing iron overload which is not invasive. New magnet resonance imaging (MRI) relaxation techniques (T2*MRI) can be used to indirectly assess the liver iron content and iron in the heart. Results of T2*MRIs show excellent correlation with liver iron content and heart function. The use of this method of assessment will minimize the risk and inconvenience of liver biopsy and possibly allow more frequent evaluations for iron overload, thus better treatment for these patients.

Participants in this study will undergo both liver biopsy for liver iron content and T2* MRI of the liver and the heart. Results from the procedures performed in this study will be compared, with the end result being the possible elimination of invasive procedures to diagnose iron overload.

详细描述

Quantitative measurements of hepatic and cardiac iron by single-breath-hold MRI T2* will allow us to determine the value of this technique as a non-invasive method of monitoring liver and cardiac iron content. By obtaining T2 measurements, we will be able to compare two different techniques for non-invasive iron assessment. With regard to the liver, we will correlate T2* measurements with the gold standard, LIC on liver biopsy. Because it is not feasible to perform cardiac biopsies to evaluate the degree of cardiac hemosiderosis, we will evaluate the relationships between cardiac T2* values and left and right diastolic function, left ventricular ejection fraction, left ventricular end-systolic volume and left ventricular mass index obtained by echocardiography and MUGA scans that are performed as part of the routine clinical care of these patients. In order to estimate whether cardiac T2* values are clinically relevant, we will also investigate the relationship between T2* values and the need for cardiac medication due to cardiac hemosiderosis. Cardiac and hepatic T2* measurements will also be compared to their visual appearances on T2* MR images in order to investigate the relationship between these two assessments. Cardiac and hepatic T2* and their respective visual appearances on T2* MR images will be compared with serum ferritin to evaluate the potential relationships among these measurements of iron overload.

Amen T2* and T2 phantoms are devices that allow calibration of the MR measurements for absolute iron content. Phantoms are test tubes filled with aqueous solutions or gel compounds of materials that mimic various tissue relaxation times (T1, T2 and T2*). Phantoms are commonly used in MRI when quantification is desired. Our phantom will consist of a multitude of small vials which will be visible in the imaging plane. The relaxation times vary in the different vials of the phantom and are known very accurately, especially the T2 and T2* values, which vary over the physiological relevant range. This way the phantom can be used to calibrate the T2* values obtained from the patients heart and liver and eventually be correlated to absolute iron concentrations.

If accurate, the T2* MRI technique would ultimately allow a non-invasive method of quantitatively assessing myocardial and liver iron accumulation, and could predict the degree of morbidity due to iron overload. This new technique could greatly improve the care of our iron overloaded patients by offering a practical and risk free method for evaluation of body iron load. We plan to apply this preliminary information into future studies in this area. Eventually we plan to use the T2* MRI measurements in longitudinal studies of patients with iron overload, both to assess their degree of iron burden and monitor chelation therapy treatments.

Amen Dark blood applications are state-of-the-art in cardiac MRI and commonly applied. There is no risk associated with the dark blood preparation. Comparison of dark and bright blood measurements will show whether both sequences yield similar results and whether one technique is less susceptible to cardiac motion and associated artifacts, thereby offering a higher accuracy and a smaller error in the calculation of T2* and iron concentration.

Information about the heart function can be obtained using MRI techniques, however this information needs to be validated in different populations, such as patients with iron overload. If MR data show a high correlation with echocardiography and MUGA functional data, subsequent protocols could be conducted where the functional information can be gained with an MR measurement, thereby avoid acquiring a MUGA scan and eliminating the exposure to radiation as well as streamlining the protocol by just adding a few additional measurements to an already scheduled MR iron scan. Performing cardiac measurement in a few patients using the MRI technique will allow us to expand the use of this technique for future and larger studies.

研究设计

研究类型
Observational
观察模型
Case Only
时间视角
Prospective

入排标准

年龄范围
7 Years 至 —(Child, Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Participant is greater than or equal to 7 years of age
  • Participant needs a liver biopsy for monitoring iron overload
  • Participant is willing to have magnetic resonance testing

排除标准

  • Patients with surgical clips placed in the United States after August 15th 1996 will be eligible to participate on the study.
  • Contraindication to performing magnetic resonance testing, such as the presence of ferromagnetic material in the body
  • Cannot tolerate an MRI without sedation or anesthesia.

研究者

申办方类型
Other
责任方
Sponsor

研究点 (1)

Loading locations...

相似试验

Pilot Study of Non-Invasive Assessment of Hepatic... | 临床试验