跳至主要内容
临床试验/NCT05797350
NCT05797350招募中不适用

Paul Glaucoma Implant Versus Ahmed Glaucoma Valve in Childhood Glaucoma

Al Watany Eye Hospital1 个研究点 分布在 1 个国家目标入组 24 人开始时间: 2022年9月1日最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
招募中
入组人数
24
试验地点
1
主要终点
IOP Reduction

研究概览

简要总结

A randomized controlled trial comparing the efficacy and safety of Paul glaucoma implant and Ahmed glaucoma valve in refractory childhood glaucoma patients

详细描述

A prospective randomized controlled trial was conducted at Al Watany Eye Hospital in Egypt. Patients with refractory primary or secondary childhood glaucoma who glaucoma specialist has decided to perform a tube implant to control their intraocular pressure are randomized to receive either Paul or Ahmed glaucoma drainage devices.

Patients will be followed up for at least one year during which the following data are collected.

Age, sex, laterality, preoperative and postoperative intraocular pressure and glaucoma medications at 1,3,6, 9, and 12 months visits. Any intraoperative or postoperative complications will be recorded

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Treatment
盲法
None

入排标准

年龄范围
0 Years 至 18 Years(Child, Adult)
性别
All
接受健康志愿者
否

入选标准

  • •Childhood glaucoma patients (whether primary or secondary) including Juvenile open angle glaucoma if the age at the time of surgery was ≤18 years.
  • •The included patients are those with refractory glaucoma who require a tube to control their intraocular pressure.

排除标准

  • •Any patient with incomplete data or has a follow-up less than 1 year will be excluded from the study.

研究组 & 干预措施

Paul Glaucoma Implant

Active Comparator

The Paul glaucoma implant (PGI) will be used as an active comparator group to compare its effectiveness and safety with the Ahmed glaucoma valve in the treatment of childhood glaucoma. The PGI works by diverting excess fluid from the eye to a plate placed under the conjunctiva, which allows the fluid to drain away from the eye and be absorbed. This helps to lower the pressure inside the eye, which is important for preventing vision loss and other complications associated with glaucoma.

The PGI has a smaller internal and external tube diameter than the Ahmed glaucoma valve, which reduces the contact area between the tube and the corneal endothelium. This theoretically reduces the rate of endothelial cell loss, which can be a complication of GDDs. Additionally, the extraocular portion of the PGI is smaller, which may reduce the long-term risk of tube erosion and exposure.

The smaller lumen may theoretically reduce the risk of postoperative hypotony as well.

干预措施: Glaucoma Drainage Device (Device)

Ahmed Glaucoma valve

Active Comparator

The Ahmed glaucoma valve (AGV) arm of the study is the active comparator group and is intended to be directly compared to the Paul glaucoma implant (PGI) in treating childhood glaucoma. The AGV is a type of glaucoma drainage device that is designed to lower intraocular pressure in patients with refractory glaucoma. It is made of a rigid plastic material and consists of a small drainage tube that is inserted into the eye and a valve mechanism that helps regulate the flow of aqueous humor from the eye to the external drainage tube.

The AGV is implanted during a surgical procedure, and its design allows it to be placed in a variety of locations in the eye. The valve mechanism helps to regulate the flow of aqueous humor, and the device is designed to be long-lasting with a low risk of complications. The AGV is a well-established treatment option for patients with refractory glaucoma and has been used for many years in clinical practice.

干预措施: Glaucoma Drainage Device (Device)

结局指标

主要结局

IOP Reduction

时间窗: 1 year

More than 20% change from baseline without development of vision threatening complications

次要结局

  • Post-operative complications(1 year)
  • Glaucoma Medication Alterations(1 year)

研究者

申办方类型
Other
责任方
Principal Investigator
主要研究者

Mohamed El Baharwy

Clinical Professor

Al Watany Eye Hospital

研究点 (1)

Loading locations...

相似试验