MedPath

The Influence of Fasting on Selected Hemodynamic Parameters Measured in a Non-invasive Way

Not Applicable
Completed
Conditions
Perioperative Complication
Hemodynamic Instability
Interventions
Dietary Supplement: Nutricia Pre-op, 400 milliliters, per os
Registration Number
NCT04972500
Lead Sponsor
Medical University of Gdansk
Brief Summary

Preoperative fasting is considered to be refraining from taking meals for at least 6 hours and clear fluids for at least 2 hours before anesthesia. On the one hand, it is a procedure that reduces the risk of aspiration of chyme and the occurrence of Mendelson's syndrome, and on the other hand, it is one of the causes of water and carbohydrate disturbances in patients undergoing general anesthesia. Most of them experience some degree of dehydration in the preoperative period. It is associated with a worse prognosis. Due to the negative impact of fasting on homeostasis, as well as significant changes in heart rate in participants in the previous study, we decided to measure the hemodynamic parameters during fasting. The development of impedance cardiography techniques enables the measurement of these parameters by a non-invasive method.

After obtaining the participant's written consent to participate in the study, the first measurement of body weight, blood pressure using a non-invasive method and hemodynamic parameters using a non-invasive impedance cardiography method using the Niccomo ™ device (Medizinische Messtechnik GmbH) will be performed in the evening. The subject will then be asked to refrain from food for at least 10 hours and fluid for 6 hours before the next measurement. The next morning, another measurement will be made and the participant will be randomly assigned to one of two groups: subjects in the first group will be asked to refrain from eating and drinking for another 2 hours, while subjects in the second group per os will receive 400 milliliters of PreOp® (Nutricia ™ preparation intended for preoperative dietary management in surgical patients, containing carbohydrates and electrolytes). After another two hours, the third measurement of the tested parameters will be performed. The obtained results will be subjected to statistical analysis consisting in comparing the values of hemodynamic parameters between the studied groups at appropriate measurement points.

Detailed Description

Not available

Recruitment & Eligibility

Status
COMPLETED
Sex
All
Target Recruitment
100
Inclusion Criteria
  • American Society of Anesthesiology (ASA) general condition assessment 1 or 2
Exclusion Criteria
  • Chronic kidney disease
  • Circulatory failure
  • Lung diseases
  • Diseases of the heart valves
  • History of hypoglycaemic episodes or any carbohydrate disturbance.
  • Height less than 120 cm or greater than 230 cm
  • Body weight less than 30 kg or greater than 155 kg.

Study & Design

Study Type
INTERVENTIONAL
Study Design
PARALLEL
Arm && Interventions
GroupInterventionDescription
Pre-opNutricia Pre-op, 400 milliliters, per osNutricia Pre-op, 400 milliliters, per os
Primary Outcome Measures
NameTimeMethod
Changes in heart rate (HR)Changes form baseline after 10 hours of fasting and after 2 hours of pre-op administration

Heart rate will be measured non-invasively with Niccomo™(Medizinische Messtechnik GmbH) device.

Heart rate will be measured in 1/min (beats per minute).

Changes in cardiac index (CI)Changes form baseline after 10 hours of fasting and after 2 hours of pre-op administration

Cardiac index will be measured non-invasively with Niccomo™(Medizinische Messtechnik GmbH) device.

Cardiac index will be measured in l/min/m\^2 (liters per minute per square meter).

Changes in systemic vascular resistance index (SVRI)Changes form baseline after 10 hours of fasting and after 2 hours of pre-op administration

Systemic vascular resistance index will be measured non-invasively with Niccomo™(Medizinische Messtechnik GmbH) device.

Systemic vascular resistance index will be measured in dyn\*s\*cm\^-5\*m\^2 (dyne multiply by second multiply by centimeters to the power of minus 5 multiply by square meter)

Changes in stroke volume (SV)Changes form baseline after 10 hours of fasting and after 2 hours of pre-op administration

Stroke volume will be measured non-invasively with Niccomo™(Medizinische Messtechnik GmbH) device.

Stroke volume will be measured in mL (milliliters).

Secondary Outcome Measures
NameTimeMethod

Trial Locations

Locations (1)

Medical University of Gdansk - Departament of Anesthesiology and Intensive Care

🇵🇱

Gdańsk, Pomorskie, Poland

© Copyright 2025. All Rights Reserved by MedPath