Comparison Between Perfusion Index and Pulse Pressure Variability for Prediction of Intravascular Volume During Major Abdominal Surgeries
试验速览
- 阶段
- 不适用
- 状态
- 进行中(未招募)
- 入组人数
- 50
- 试验地点
- 1
- 主要终点
- Comparison between perfusion index and pulse pressure variability for prediction of intravascular volume during major abdominal surgeries
研究概览
简要总结
Each year, at least 310 million patients undergo major surgery worldwide, procedures that involve the administration of intravenous fluids Intraoperative hemodynamic management is challenging because precise assessment of the adequacy of the intravascular volume is difficult during surgery Achieving optimal IV fluid therapy should improve perioperative outcomes and is a key component in many perioperative guidelines and pathways. IV fluids, like other medications, should only be given in well-defined protocols according to individual needs More recently, so called dynamic predictors of fluid responsiveness such as pulse pressure variation (PPV), stroke volume variation (SVV), or Perfusion Index (PI) have been used in intraoperative goal directed fluid therapy ( GDT) hemodynamic protocols
研究设计
- 研究类型
- Observational
- 观察模型
- Cohort
- 时间视角
- Prospective
入排标准
- 年龄范围
- 18 Years 至 65 Years(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •Inclusion Criteria:
- •ASA 1, 2 Age: 18-65 Undergoing major abdominal surgeries Mechanically ventilated and sedated patients
排除标准
- •Chronic cardiac arrhythmias High doses of vasopressors Altered myocardial function (left ventricular ejection fraction < 50%) Peripheral vascular disease Severe respiratory disease Pulmonary or intra-abdominal hypertension Open chest
- •Exclusion Criteria:
结局指标
主要结局
Comparison between perfusion index and pulse pressure variability for prediction of intravascular volume during major abdominal surgeries
时间窗: 6 months
Comparing 2 percentage; Perfusion index and pulse pressure variability in assessment of intravascular volume and fluid responsiveness of the patient during major abdominal surgeries PI is a ratio of pulsatile light absorption to continuous light absorption, denoted as AC/DC. Normal PI values can vary widely, ranging from less than 1% to greater than 10%. The pulse pressure variation (PPV) is a percentage measure of the respiratory effect on the variation of systemic arterial blood pressure in patients receiving full mechanical ventilation The PI will be monitored by attaching a sensor to the patient's finger (Ultralife Pulse Oximeter JPD-500D). The PPV will be measured using an arterial line in radial artery Patients will receive maintenance and deficit fluids then measuring perfusion index (PI) and pulse pressure variability (PPV) which the cut off value of is higher than 13% for more than 5 min, values of PI in percentage in corresponding time will be measured and recorded
次要结局
未报告次要终点