Impact of Steerable Delivery Sheaths on Successful Closure of Left Atrial Appendage With AMULET Dual Mechanism Closure Device (STEER-CLOSE Study)
试验速览
- 阶段
- 不适用
- 状态
- 尚未招募
- 发起方
- 入组人数
- 300
- 试验地点
- 14
- 主要终点
- Need for Pericardiocentesis
研究概览
简要总结
The novel Amplatzer steerable delivery sheath (Abbott Vascular) is found to be safe and effective in performing LAAO procedure. However, the procedural outcomes have not been compared with the traditional non-steerable fixed curve sheath. In this study investigators aim to compare the outcome of patients undergoing left atrial appendage occlusion with the dual mechanism closure Amulet device using non-steerable fixed curve sheath versus a novel steerable sheath.
详细描述
Atrial fibrillation (AF) is the most common abnormal heart rhythm associated with substantial morbidity and mortality. It is one of the strongest risk factors of systemic thromboembolism (TE), with stroke being the most serious outcome. Prevention of stroke is the cornerstone of managing AF, which can be achieved either by oral anticoagulation (OAC) or Percutaneous left atrial appendage occlusion (LAAO) in patients who have a contraindication to OAC. Heterogeneity in cardiac chamber size, interatrial septum, LAA anatomy and orientation, operator experience and currently available fixed curve sheaths add to the complexity of the procedure. Alignment of LAAO device along the access of the left atrial appendage body is an important factor in improving closure rates. The devices which are currently approved by FDA for LAA closure in the U.S. are Amplatzer Amulet device (Abbott Medical) and Watchman and Watchman FLX devices (Boston Scientific). In a recent study, Amplatzer Amulet device was found to be noninferior in terms of safety and effectiveness, with superior LAA occlusion rates but higher device-related complications as compared to first generation watchman device. The LAAO device sheaths that are used currently have fixed shapes and angles that may not be optimal for some LAA anatomy, which can lead to excessive device manipulation, prolonged procedure time, and potentially suboptimal co-axiality during the process. This may lead to increase device related complications. The new Amplatzer steerable delivery sheath (Abbott Vascular) is designed to provide distal bidirectional steerability of the sheath for Amulet implantation. Such steerability may enable successful endovascular closure of greater proportion of LAA, allow precise position of the transseptal puncture, and potentially reduce procedural times and complications with complex cases.
Investigators hypothesize that the use of novel steerable sheath for LAAO closure is safer and more effective as compared to non-steerable fixed curve sheath
研究设计
- 研究类型
- Interventional
- 分配方式
- Non Randomized
- 干预模型
- Parallel
- 主要目的
- Other
- 盲法
- None
入排标准
- 年龄范围
- 18 Years 至 —(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •Patients with atrial fibrillation who meets the indication/criteria for left atrial appendage occlusion and undergoing implantation of Amplatzer™ Amulet™ Left Atrial Appendage Occluder device
排除标准
- •Patient been/being implanted with device other than Amplatzer™ Amulet™ Left Atrial Appendage Occluder
- •Pregnant or breastfeeding patients
- •Prisoners
- •Patients not willing to participate in the study
结局指标
主要结局
Need for Pericardiocentesis
时间窗: 7 days
Need for pericardiocentesis within 7 days of implantation
Number of participants with Acute Closure of Left Atrial Appendage
时间窗: 1 day
Acute closure ( less than or equal to 3mm) of the left atrial appendage after Left Atrial Appedage Occlusion(LAAO) procedure
Number of patients with Cardiac Perforation
时间窗: 7 days
Number of patients with cardiac perforation
次要结局
- Number of participants with Device related thrombus (DRT)(45 days)
- Number of participants with Transient ischemic attack (TIA) or cerebrovascular accident (CVA)(6 months)
- Number of devices(1 day (procedure day))
- Number of device repositions(1 day (procedure day))
- Closure Rates(45 days)