跳至主要内容
临床试验/NCT05091515
NCT05091515已完成不适用

Study of Thermoregulatory Reactions of the Body of Medical Workers Who Use Personal Protective Equipment From Biological Hazards

Federal State Budgetary Scientific Institution "Izmerov Research Institute of Occupational Health"1 个研究点 分布在 1 个国家目标入组 25 人开始时间: 2021年3月29日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
25
试验地点
1
主要终点
Blood pressure

研究概览

简要总结

This research will provide data on thermal condition, functional status and working conditions of medical workers who use personal protective equipment from biological hazards. Acquired data will be used to define acceptable period of use for these protective costumes.

详细描述

This research will recruit 14-20 volunteers. During 8 hours each subject will perform their work using protective costume. Heart rate, electrocardiogram, oxygenation, skin and air temperature under costume and hygrometric data will be registered. Also there will be questionnaires for volunteers for subjective assessment of thermal and moisture sensations and assessment of working conditions.

研究设计

研究类型
Observational
观察模型
Case Control
时间视角
Prospective

入排标准

年龄范围
18 Years 至 55 Years(Adult)
性别
All
接受健康志愿者

入选标准

  • healthy individuals (based on medical screening)

排除标准

  • endocrinological diseases and disorders
  • health deviations at the time of the study

结局指标

主要结局

Blood pressure

时间窗: 8 hours

Electrocardiographic system "Poly-Specter-SM" (LLC "Neurosoft", Russia)

Skin thermometry

时间窗: 8 hours

DS1923-F5 Thermochron iButtons ("MaximIntegratedProducts, Inc", USA)

Hygrometry under costume

时间窗: 8 hours

DS1923-F5 Thermochron iButtons ("MaximIntegratedProducts, Inc", USA)

Electrocardiography

时间窗: 8 hours

Electrocardiographic system "Poly-Specter-SM" (LLC "Neurosoft", Russia), all parameters.

Heart rate

时间窗: 8 hours

Electrocardiographic system "Poly-Specter-SM" (LLC "Neurosoft", Russia)

Breathing rate

时间窗: 8 hours

Electrocardiographic system "Poly-Specter-SM" (LLC "Neurosoft", Russia)

Air thermometry and hygrometry

时间窗: 8 hours

"METEOSCOP-M" (LLC "NTM-Zashchita", Russia)

次要结局

  • Oxygenation(8 hours)

研究者

发起方
Federal State Budgetary Scientific Institution "Izmerov Research Institute of Occupational Health"
申办方类型
Other
责任方
Principal Investigator
主要研究者

Andrey Mikhailovich Geregey

Head of the Laboratory of Personal Protective Equipment and Industrial Exoskeletons

Federal State Budgetary Scientific Institution "Izmerov Research Institute of Occupational Health"

研究点 (1)

Loading locations...

相似试验