Clinical Trials/NCT01861925
NCT01861925
Completed
Not Applicable

Lenstar LS 900 Topography

Haag-Streit AG1 site in 1 country50 target enrollmentJune 2013

Overview

Phase
Not Applicable
Intervention
Not specified
Conditions
Corneal Topography
Sponsor
Haag-Streit AG
Enrollment
50
Locations
1
Primary Endpoint
In-vivo Repeatability of Corneal Topography Measurements With Lenstar LS 900 Topography: Sample Mean of Differences of Mean Power and Sample Mean of Std. Dev of Local Power Differences Between Two Consecutive Measurements
Status
Completed
Last Updated
11 years ago

Overview

Brief Summary

The purpose of this study is to quantify in-vivo repeatability of a new corneal topography measurement mode of an optical biometer, and the clinical performance of measurement in comparison to reference devices.

Registry
clinicaltrials.gov
Start Date
June 2013
End Date
July 2013
Last Updated
11 years ago
Study Type
Observational
Sex
All

Investigators

Responsible Party
Sponsor

Eligibility Criteria

Inclusion Criteria

  • 18 years or older

Exclusion Criteria

  • No corneal transplants
  • No corneal scar(s)
  • No acute infections of the eye
  • No weak fixation
  • No suspected lack of compliance
  • No vulnerable population

Outcomes

Primary Outcomes

In-vivo Repeatability of Corneal Topography Measurements With Lenstar LS 900 Topography: Sample Mean of Differences of Mean Power and Sample Mean of Std. Dev of Local Power Differences Between Two Consecutive Measurements

Time Frame: 1 day of examination

Corneal topography is a measurement of the shape of the anterior cornea. The shape of a cornea can be fully quantified by providing a map of local power. "Diopter" is the unit of refractive power of a lens. In case of the cornea, the power K \[diopter\] is related to the radius (curvature) R \[mm\] of the best fitting sphere by the relation K=337.5/R. Here, corneal topography measurements are implemented by the Placido method, i.e. by analyzing the reflection image of a ring-shaped illumination. According to International Standards Organization (ISO) 19980-2012, repeatability of corneal topography is assessed on the central cornea: area with diameter d\<=3mm, and middle cornea: 3mm\<d\<=6mm. "power difference (2 rep. meas.)": sample mean and 95% C.I. of differences of spatial mean of corneal power between two consecutive measurements. "power difference 2 std.dev.": sample mean of twice the deviation of local power differences (two consecutive measurements).

Secondary Outcomes

  • Equivalence of Corneal Topography Measurement Between Lenstar LS 900 Topography and Atlas 9000: Sample Mean of Differences of Mean Power and Sample Mean of Std. Dev of Local Power Differences for One Measurement Per Device.(1 day of examination)