跳至主要内容
临床试验/NCT04179539
NCT04179539已完成不适用

Gallium68 Ventilation/Perfusion PET/CT for Pulmonary Embolism Diagnosis: a Diagnostic Accuracy Study vs CT Pulmonary Angiography

University Hospital, Brest2 个研究点 分布在 1 个国家目标入组 100 人开始时间: 2019年12月6日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
入组人数
100
试验地点
2
主要终点
Sensitivity of V/Q PET/CT for PE diagnosis

研究概览

简要总结

This study evaluates the diagnostic accuracy (sensitivity, specificity) of V/Q PET/CT for the diagnosis of pulmonary embolism (PE), using CT pulmonary angiography as a reference standard.

详细描述

V/Q PET/CT imaging is now possible by substituting 99mTc with 68Ga, a positron-emitting radionuclide, using the same carrier molecules as conventional V/Q imaging. Ventilation imaging can be performed with 68Ga-carbon nanoparticles using the same synthesis device as Technegas. Perfusion imaging can be performed with 68Ga-macroaggregated albumin (68Ga-MAA).Technical advantages of PET compared to SPECT include higher sensitivity, higher spatial and temporal resolution and superior quantitative capability. This offers the opportunity to improve the accuracy of V/Q imaging in patients with suspected PE, while decreasing the acquisition time.

The aim is to perform a formal diagnostic accuracy study of V/Q PET/CT for PE, using CTPA as a reference standard.

Patients with suspected acute PE undergo CTPA and V/Q PET/CT imaging within 24 hours.

V/Q PET/CT images are not used for patients management.

After completion of inclusion, central readings of scans will be conducted independently.

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Diagnostic
盲法
None

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Patient with suspected first episode of acute PE,
  • Age ≥ 18 years .
  • Insured patient.

排除标准

  • Patients with a clinically suspected massive PE.
  • Contraindication to contrast media (including renal insufficiency with creatinine clearance < 30 ml/min).
  • Inability to perform CTPA and V/Q PET/CT within 24 hours.
  • History of deep vein thrombosis or PE
  • Unable/unwilling to give informed consent.
  • Pregnancy / breast-feeding.
  • Patient under guardianship or curatorship

结局指标

主要结局

Sensitivity of V/Q PET/CT for PE diagnosis

时间窗: Baseline

Proportion of patients with a positive V/Q PET/CT among patients with PE according to the reference standard (CTPA).

Specificity of V/Q PET/CT for PE diagnosis

时间窗: Baseline

Proportion of patients with a negative V/Q PET/CT among patients without PE according to the reference standard (CTPA).

次要结局

未报告次要终点

研究者

申办方类型
Other
责任方
Sponsor

研究点 (2)

Loading locations...

相似试验